6066 Datasheet
The Belden 6066 is a Teck90 1000V cable designed with three 12 AWG bare copper conductors and one 14 AWG bare copper ground wire, featuring XLPE insulation, steel interlock armor, and a black PVC outer jacket. It is suitable for CEC power and control applications in indoor and outdoor environments with sunlight and UV resistance. The cable supports an operating temperature range of -40°C to +90°C and a maximum current of 30 Amps per conductor.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6066 Key Specifications
- Conductor Resistance (DCR)
- 1.68 Ohm/1000ft (conductors), 2.67 Ohm/1000ft (ground)
- Max Current
- 30 Amps per Conductor at 30°C
- Voltage Rating
- 1000 V (TECK 90)
- Operating Temperature
- -40°C to +90°C (UL Temperature 90°C)
- Bulk Cable Weight
- 451 lbs/1000ft
- Conductors
- 3 x 12 AWG Bare Copper (7x20 stranding), Ground: 1 x 14 AWG Bare Copper (7x22 stranding)
- Max Pull Tension
- 515 lbs (234 kg)
- Nominal Overall Diameter
- 0.802 in
Characteristics (datasheet)
- Voltage Rating
- 1000 V (TECK 90)
- Conductors
- 3 x 12 AWG Bare Copper (7x20 stranding), Ground: 1 x 14 AWG Bare Copper (7x22 stranding)
- Max Current
- 30 Amps per Conductor at 30°C
- Conductor Resistance (DCR)
- 1.68 Ohm/1000ft (conductors), 2.67 Ohm/1000ft (ground)
- Operating Temperature
- -40°C to +90°C (UL Temperature 90°C)
- Nominal Overall Diameter
- 0.802 in
- Bulk Cable Weight
- 451 lbs/1000ft
- Max Pull Tension
- 515 lbs (234 kg)
6066 Applications
- CEC Power and Control Applications
Other Belden parts
- 21674 — Belden part 21674 is a CSA Type TC tray cable rated 600 V with two 3/0 AWG bare...
- 8102 — The Belden 8102 is a computer EIA RS-232/422 low-capacitance cable designed for...
- 83307E — The Belden 83307E is a high-temperature single-conductor electronic cable featur...
- 65834 — The Belden 65834 is a 34-conductor, 18 AWG bare copper flexible control cable wi...
- 1934 — The Belden 1934 is a heavy-duty 2-conductor 18 AWG stranded bare copper cord wit...
- 55093 — The Belden 55093 is a 3-conductor, 24 AWG tinned copper cable with FEP insulatio...
- 25484 — Belden part 25484 is an XTRAGUARD 2 cable with 4 pairs of 22 AWG (7x30) stranded...
- 934063107 — Test Lead, 4mm Banana Plug to 4mm Banana Plug, White, 60 V, 32 A, 1 m ;RoHS Comp...
More Bulk Wire Cable
- 45373 — Belden 45373 is an XTRAGUARD 4 multi-pair cable built with 3 pairs of 18 AWG (16...
- 37103 — Belden 37103 is a rubber lead wire using a 3 AWG tinned copper conductor with 13...
- 29512 — Belden 29512 is a flexible 600 V/1000 V motor supply cable built for variable fr...
- 5160C — The Belden 5160C is an XTRAGUARD 1, 10-conductor 20 AWG tinned copper cable with...
- 45463 — Belden part 45463 is an XTRAGUARD 4 multi-conductor cable with 3 conductors of 2...
- 29017 — Belden part 29017 is an ACIC 600 V Canadian instrumentation cable (TC-ACIC) with...
- 5093C — The Belden 5093C (XTRAGUARD 1) is a 3-conductor, 24 AWG tinned copper cable with...
- 85243CY — The part 85243CY is an XTRAGUARD FLEX continuous flex control cable featuring 3...
6066 FAQ
What is 6066?
6066 is a Bulk Wire Cable from Belden. The Belden 6066 is a Teck90 1000V cable designed with three 12 AWG bare copper conductors and one 14 AWG bare copper ground wire, featuring XLPE insulation, steel interlock armor, and a black PVC outer jacket. It is suitable for CEC power and control applications in indoor and outdoor environments with sunlight and UV resistance. The cable supports an operating temperature range of -40°C to +90°C and a maximum current of 30 Amps per conductor.
Who manufactures 6066?
6066 is manufactured by Belden.
Where can I download the 6066 datasheet PDF?
The 6066 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6066 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 451 lbs/1000ft |
| Conductor Resistance (DCR) | 1.68 Ohm/1000ft (conductors), 2.67 Ohm/1000ft (ground) |
| Conductors | 3 x 12 AWG Bare Copper (7x20 stranding), Ground: 1 x 14 AWG Bare Copper (7x22 stranding) |
| Max Current | 30 Amps per Conductor at 30°C |
| Max Pull Tension | 515 lbs (234 kg) |
| Nominal Overall Diameter | 0.802 in |
| Operating Temperature | -40°C to +90°C (UL Temperature 90°C) |
| Voltage Rating | 1000 V (TECK 90) |