55386 Datasheet

BeldenBulk Wire Cable

The Belden 55386 is a high-performance 6-conductor, 18 AWG (7x26) tinned copper cable featuring FEP insulation, an overall aluminum/polyester shield, and a natural/translucent FEP outer jacket. Rated for 300 V and a maximum operating temperature of 150°C (UL) with an operating range of -80°C to +200°C, it is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, and instrumentation systems.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

55386 Key Specifications

Nom. Capacitance Cond-to-Cond / Cond-to-Other
26 pF/ft (85 pF/m) / 47 pF/ft (150 pF/m)
Nom. Inductance
0.16 µH/ft (0.52 µH/m)
UL Voltage Rating
300 V (CMP, AWM 20229)
UL Temperature / Operating Temperature
150°C / -80°C To +200°C
Conductor count and size
6 conductors, 18 AWG 7x26 TC - Tinned Copper
Insulation material and thickness
FEP - Fluorinated Ethylene Propylene, 0.010 in (0.25 mm)
Max. Pull Tension
52 lbs (24 kg)
Min. bend radius (stationary)
2.7 in (69 mm)

55386 Marking Code (SMD Code)

Top marking: Alpha Wire -* P/N 55386 6C 18 AWG XTRAGUARD(R) 5 - 18 AWG SHIELDED 150C (UL) CMP OR AWM 20229 -- LLXXXXXX CSA CMP FT6 CE ROHS

Characteristics (datasheet)

Conductor count and size
6 conductors, 18 AWG 7x26 TC - Tinned Copper
Insulation material and thickness
FEP - Fluorinated Ethylene Propylene, 0.010 in (0.25 mm)
Outer shield type and coverage
Tape, Bi-Laminate (Alum+Poly), 100% coverage with 18 AWG (7x26) TC drainwire
Outer jacket material and thickness
FEP - Fluorinated Ethylene Propylene, 0.027 in (0.69 mm)
Nominal overall cable diameter
0.271 in (6.88 mm)
UL Voltage Rating
300 V (CMP, AWM 20229)
UL Temperature / Operating Temperature
150°C / -80°C To +200°C
Nom. Capacitance Cond-to-Cond / Cond-to-Other
26 pF/ft (85 pF/m) / 47 pF/ft (150 pF/m)
Nom. Inductance
0.16 µH/ft (0.52 µH/m)
Nom Outer Shield DCR
45 Ohm/1000ft (150 Ohm/km)
Min. bend radius (stationary)
2.7 in (69 mm)
Max. Pull Tension
52 lbs (24 kg)

55386 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking
  • Serial communication
  • Control panels
  • Automation equipment
  • Instrumentation systems

Other Belden parts

  • 9008 — The Belden 9008 is a single-conductor coaxial cable featuring a 13 AWG bare copp...
  • 9744 — The Belden 9744 is a 2-pair 22 AWG stranded tinned copper electronic cable with...
  • 83709 — The Belden 83709 is a high-temperature, 9-conductor 16 AWG tinned copper cable w...
  • 86608CY — The 86608CY is an XTRAGUARD FLEX continuous flex data cable featuring 8 pairs of...
  • 83046 — The Belden 83046 is a high-temperature plastic lead wire featuring a 26 AWG silv...
  • 3018A — The Belden 3018A is a UL-listed instrumentation cable containing two triads of 2...
  • 9553 — The Belden 9553 is a high-performance instrumentation cable consisting of 3 pair...
  • 7423W — The Belden 7423W is a high-flex MachFlex™ cable designed for continuous flex app...

More Bulk Wire Cable

  • 1191AM — The Belden 1191AM is a CATV video cable of RG6 type, featuring an 18 AWG solid b...
  • 7784E — The 7784E is a triaxial cable featuring a 15 AWG solid bare copper conductor, po...
  • 1061A — The Belden 1061A is a 36-pair instrumentation and control cable featuring 20 AWG...
  • 82777 — The Belden 82777 is an audio, control, and instrument cable designed for indoor...
  • 45271 — Belden 45271 is an XTRAGUARD 4 single-pair cable built with 24 AWG (7x32) strand...
  • 5403FE — The Belden 5403FE is a security and sound riser-CMR cable designed for indoor us...
  • 7851A — The Belden 7851A is a Category 6+ enhanced premise horizontal cable featuring fo...
  • 5404 — The Belden 5404 is a 4-conductor, 22 AWG tinned copper control cable with PVC in...

55386 FAQ

What is 55386?

55386 is a Bulk Wire Cable from Belden. The Belden 55386 is a high-performance 6-conductor, 18 AWG (7x26) tinned copper cable featuring FEP insulation, an overall aluminum/polyester shield, and a natural/translucent FEP outer jacket. Rated for 300 V and a maximum operating temperature of 150°C (UL) with an operating range of -80°C to +200°C, it is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, and instrumentation systems.

Who manufactures 55386?

55386 is manufactured by Belden.

What is the marking code of 55386?

According to its datasheet, 55386 is marked "Alpha Wire -* P/N 55386 6C 18 AWG XTRAGUARD(R) 5 - 18 AWG SHIELDED 150C (UL) CMP OR AWM 20229 -- LLXXXXXX CSA CMP FT6 CE ROHS".

Where can I download the 55386 datasheet PDF?

The 55386 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 55386 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor count and size6 conductors, 18 AWG 7x26 TC - Tinned Copper
Insulation material and thicknessFEP - Fluorinated Ethylene Propylene, 0.010 in (0.25 mm)
Max. Pull Tension52 lbs (24 kg)
Min. bend radius (stationary)2.7 in (69 mm)
Nom. Capacitance Cond-to-Cond / Cond-to-Other26 pF/ft (85 pF/m) / 47 pF/ft (150 pF/m)
Nominal overall cable diameter0.271 in (6.88 mm)
Nom. Inductance0.16 µH/ft (0.52 µH/m)
Nom Outer Shield DCR45 Ohm/1000ft (150 Ohm/km)
Outer jacket material and thicknessFEP - Fluorinated Ethylene Propylene, 0.027 in (0.69 mm)
Outer shield type and coverageTape, Bi-Laminate (Alum+Poly), 100% coverage with 18 AWG (7x26) TC drainwire
UL Temperature / Operating Temperature150°C / -80°C To +200°C
UL Voltage Rating300 V (CMP, AWM 20229)