5529 Datasheet
The Belden 5529 (XTRAGUARD 1) is a 9-conductor, 18 AWG tinned copper cable with PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 600 V and operates within a temperature range of -30°C to +105°C. It is primarily used for data, communication, audio, and low-level signal transmission, as well as in industrial networking, control panels, automation equipment, and instrumentation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5529 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 32 pF/ft (100 pF/m)
- Nom. Capacitance Cond-to-Other
- 58 pF/ft (190 pF/m)
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
- Voltage Rating
- 600 V (MTW, AWM 20811, AWM 2501 / CSA AWM)
- Operating temperature
- -30°C to +105°C (UL temperature 105°C)
- Conductor configuration
- 9 conductors, 18 AWG (16x30) TC - Tinned Copper
- Nominal overall diameter
- 0.563 in (14.3 mm)
- Shielding
- Overall Aluminum/Polyester shield (100% coverage) + Tinned Copper braid (70% coverage)
5529 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 5529 9C 18 AWG XTRAGUARD(R) 1 (UL) MTW 600V OR AWM 2501 105C 600V OR AWM 20811 105C 600V VW-1 OR CRU AWM I/II A/B 105C 600V FT4 CE · package Cable (Slate PVC Outer Jacket, Reel, 100 ft)
Characteristics (datasheet)
- Voltage Rating
- 600 V (MTW, AWM 20811, AWM 2501 / CSA AWM)
- Conductor configuration
- 9 conductors, 18 AWG (16x30) TC - Tinned Copper
- Shielding
- Overall Aluminum/Polyester shield (100% coverage) + Tinned Copper braid (70% coverage)
- Operating temperature
- -30°C to +105°C (UL temperature 105°C)
- Nominal overall diameter
- 0.563 in (14.3 mm)
- Nom. Capacitance Cond-to-Cond
- 32 pF/ft (100 pF/m)
- Nom. Capacitance Cond-to-Other
- 58 pF/ft (190 pF/m)
- Nom. Inductance
- 0.22 µH/ft (0.72 µH/m)
5529 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 6524UE — The Belden 6524UE is a plenum-rated (CMP) security and sound cable featuring six...
- 5669 — The Belden 5669 is a 6-conductor, 26 AWG tinned copper cable with semi-rigid PVC...
- 3051 — The Belden 3051 is a single-conductor 22 AWG hook-up wire featuring a tinned cop...
- 1674A — The Belden 1674A is a conformable 50 Ohm microwave coaxial cable (M17/151 type)...
- 50062LB — The Belden 50062LB is an RS-485 cable comprising 2 pairs of 20 AWG stranded tinn...
- 70036 — The Belden 70036 is a discontinued analog audio cable containing 24 pairs of 26A...
- 6201FE — The 6201FE is a plenum-rated (CMP) security and commercial audio cable consistin...
- 6502FC — The Belden 6502FC is a plenum-rated multi-conductor cable designed for security,...
More Bulk Wire Cable
- 86506CY — The Belden 86506CY is an XTRAGUARD FLEX continuous flex data cable featuring 6 p...
- 1705 — The Belden 1705 is a single-conductor communication and control cable designed f...
- 8163 — The Belden 8163 is a computer EIA RS-232/422 digital audio cable featuring 24 AW...
- 5118C — The Belden 5118C is an 8-conductor, 24 AWG tinned copper cable with semi-rigid P...
- 45132 — Belden part 45132 is an XTRAGUARD 4 cable constructed with two pairs of 18 AWG (...
- 8742 — The Belden 8742 is a multi-conductor electronic cable consisting of three pairs...
- 78043 — The Belden 78043 is an ECOCABLE multi-conductor cable featuring three 20 AWG tin...
- 9541 — The Belden 9541 is a computer EIA RS-232 cable containing 15 conductors made of...
5529 FAQ
What is 5529?
5529 is a Bulk Wire Cable from Belden. The Belden 5529 (XTRAGUARD 1) is a 9-conductor, 18 AWG tinned copper cable with PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 600 V and operates within a temperature range of -30°C to +105°C. It is primarily used for data, communication, audio, and low-level signal transmission, as well as in industrial networking, control panels, automation equipment, and instrumentation systems.
Who manufactures 5529?
5529 is manufactured by Belden.
What is the marking code of 5529?
According to its datasheet, 5529 in Cable (Slate PVC Outer Jacket, Reel, 100 ft) is marked "Alpha Wire -* P/N 5529 9C 18 AWG XTRAGUARD(R) 1 (UL) MTW 600V OR AWM 2501 105C 600V OR AWM 20811 105C 600V VW-1 OR CRU AWM I/II A/B 105C 600V FT4 CE".
Where can I download the 5529 datasheet PDF?
The 5529 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5529 specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 9 conductors, 18 AWG (16x30) TC - Tinned Copper |
| Nom. Capacitance Cond-to-Cond | 32 pF/ft (100 pF/m) |
| Nom. Capacitance Cond-to-Other | 58 pF/ft (190 pF/m) |
| Nominal overall diameter | 0.563 in (14.3 mm) |
| Nom. Inductance | 0.22 µH/ft (0.72 µH/m) |
| Operating temperature | -30°C to +105°C (UL temperature 105°C) |
| Shielding | Overall Aluminum/Polyester shield (100% coverage) + Tinned Copper braid (70% coverage) |
| Voltage Rating | 600 V (MTW, AWM 20811, AWM 2501 / CSA AWM) |