5064C Datasheet

BeldenBulk Wire Cable

The Belden 5064C is a multi-conductor control cable featuring four 18 AWG stranded tinned copper conductors with PVC insulation and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -30°C to +105°C, offering sunlight and oil resistance alongside FT4 flammability compliance. This cable is designed for industrial control, instrumentation, and PLC/DCS systems transmitting analog and digital signals.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

5064C Key Specifications

Nom. Capacitance Cond-to-Cond
30 pF/ft (98 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)
Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Operating Temperature
-30°C To +105°C (UL Temperature: 105°C)
Conductor Configuration
4 conductors, 18 AWG, 16x30 stranded TC - Tinned Copper
Max. Pull Tension
82 lbs (37 kg)
Min. Bend Radius (Stationary / Installation)
1.3 in (33 mm)
Overall Cable Diameter (Nominal)
0.259 in (6.58 mm)

Characteristics (datasheet)

Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Conductor Configuration
4 conductors, 18 AWG, 16x30 stranded TC - Tinned Copper
Operating Temperature
-30°C To +105°C (UL Temperature: 105°C)
Overall Cable Diameter (Nominal)
0.259 in (6.58 mm)
Max. Pull Tension
82 lbs (37 kg)
Min. Bend Radius (Stationary / Installation)
1.3 in (33 mm)
Nom. Capacitance Cond-to-Cond
30 pF/ft (98 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)

5064C Applications

  • Industrial control systems, raceways, cable trays, and ducts
  • Instrumentation and control circuits
  • Analog and digital signals (4–20 mA, 0–10 V)
  • PLC and DCS systems
  • Sensors, encoders, solenoids, valves, actuators, and positioners

Other Belden parts

  • 50978 — The Belden 50978 is a highly flexible, unshielded speaker cable with four 2.5 mm...
  • 8691 — The Belden 8691 is an electronic cable consisting of six pairs of 18 AWG tinned...
  • 1121 — The Belden 1121 is a 3-conductor, 28 AWG tinned copper cable with PVC insulation...
  • 7107W — The Belden 7107W is a high-flex MachFlex™ cable containing 17+1 conductor 20 AWG...
  • 1224 — The Belden 1224 is a CAT5e+ (350 MHz) premise horizontal cable featuring four pa...
  • 85407 — The Belden 85407 is a 7-conductor, 14 AWG bare copper control cable with PVC ins...
  • 9192 — The Belden 9192 is a discontinued video triaxial cable of RG11 type, featuring a...
  • 34440 — Belden 34440 is a low temperature rubber lead wire with a 4/0 AWG (805x26) tinne...

More Bulk Wire Cable

  • 28156A — The Belden 28156A is a UL Type TC power and control cable with three 4 AWG bare...
  • 8810 — The Belden 8810 is an unshielded, 2-conductor 10 AWG speaker cable constructed w...
  • 21651 — The Belden 21651 is a 600 V Type TC/CIC power and control cable with three 8 AWG...
  • 5661 — The Belden 5661 is a 4-conductor, 14 AWG bare copper motor supply cable with PVC...
  • 2140A — The Belden 2140A is a Category 6 indoor/outdoor premise horizontal cable featuri...
  • 89855 — The Belden 89855 is a plenum-rated computer POS cable featuring 22 AWG solid tin...
  • 70032 — The Belden 70032 is a discontinued analog audio cable featuring four pairs of 26...
  • 6060 — The Belden 6060 is a Teck90 600V heavy-duty cable designed for CEC power and con...

5064C FAQ

What is 5064C?

5064C is a Bulk Wire Cable from Belden. The Belden 5064C is a multi-conductor control cable featuring four 18 AWG stranded tinned copper conductors with PVC insulation and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -30°C to +105°C, offering sunlight and oil resistance alongside FT4 flammability compliance. This cable is designed for industrial control, instrumentation, and PLC/DCS systems transmitting analog and digital signals.

Who manufactures 5064C?

5064C is manufactured by Belden.

Where can I download the 5064C datasheet PDF?

The 5064C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 5064C specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor Configuration4 conductors, 18 AWG, 16x30 stranded TC - Tinned Copper
Max. Pull Tension82 lbs (37 kg)
Min. Bend Radius (Stationary / Installation)1.3 in (33 mm)
Nom. Capacitance Cond-to-Cond30 pF/ft (98 pF/m)
Nom. Inductance0.18 µH/ft (0.59 µH/m)
Operating Temperature-30°C To +105°C (UL Temperature: 105°C)
Overall Cable Diameter (Nominal)0.259 in (6.58 mm)
Voltage Rating300 V (CMG, CM, AWM 2464, AWM 2517)