1472A Datasheet
The Belden 1472A is a UL-listed instrumentation cable designed for industrial control, DCS, and PLC systems. It features 36 pairs of 18 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. The cable is rated for 300V PLTC / 150V ITC applications and supports an operating temperature range of -30°C to +105°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1472A Key Specifications
- DC Resistance
- Pair(s) 5.86 Ohm/1000ft, Comm wire(s) 14.7 Ohm/1000ft
- Voltage rating
- 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
- Operating temperature
- -30°C to +105°C (UL temperature rating 105°C)
- Conductor configuration
- 36 pairs of 18 AWG (7x26) and 1 comm wire of 22 AWG (7x30) bare copper
- Minimum bend radius
- 10.9 in (277 mm) stationary and installation
- Nominal overall diameter
- 1.085 in (27.56 mm)
- Outer jacket
- Black PVC, nominal thickness 0.074 in (1.9 mm)
- Outer shield
- Bi-laminate (Alum+Poly) tape with 100% coverage and an 18 AWG (7x26) TC drainwire
Characteristics (datasheet)
- Conductor configuration
- 36 pairs of 18 AWG (7x26) and 1 comm wire of 22 AWG (7x30) bare copper
- Voltage rating
- 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
- Operating temperature
- -30°C to +105°C (UL temperature rating 105°C)
- Outer shield
- Bi-laminate (Alum+Poly) tape with 100% coverage and an 18 AWG (7x26) TC drainwire
- Outer jacket
- Black PVC, nominal thickness 0.074 in (1.9 mm)
- Nominal overall diameter
- 1.085 in (27.56 mm)
- DC Resistance
- Pair(s) 5.86 Ohm/1000ft, Comm wire(s) 14.7 Ohm/1000ft
- Minimum bend radius
- 10.9 in (277 mm) stationary and installation
1472A Applications
- Industrial control
- Raceways cable trays and ducts
- Digital control
- Instruments (4-20ma, 0-10v)
- Low voltage digital control (24v)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids
- Valves
- Actuators
- Positioners
Other Belden parts
- 83953 — The Belden 83953 is a Type KX thermocouple cable featuring a single pair of 16 A...
- 45004 — Belden 45004 is a 4-conductor, 22 AWG (7/30) tinned copper cable with TPE insula...
- 934087101 — 1kV 32A Red Insulated Cable Test Lead
- 3076F — The Belden 3076F is a flexible, 1-pair 18 AWG tinned copper fieldbus cable with...
- 7405W — The Belden 7405W is a high-flex MachFlex™ cable featuring eight 20 AWG bare copp...
- 9803 — The Belden 9803 is a 3-conductor, 20 AWG solid tinned copper electronic cable fe...
- 6404 — The Belden 6404 is a 5-pair, 24 AWG tinned copper conductor shielded communicati...
- 1039A — The Belden 1039A is a UL-listed instrumentation cable designed with four 16 AWG...
More Bulk Wire Cable
- 80153 — The part 80153 is a 7-conductor, 14 AWG tinned copper control cable with modifie...
- 78116 — The Belden 78116 is a 6-conductor, 26 AWG tinned copper ECOCABLE with modified p...
- 70069CH — The Belden 70069CH is a 2-pair AES/EBU digital audio cable with a 22AWG conducto...
- 82742 — The Belden 82742 is a high-temperature electronic cable featuring three pairs of...
- 34920 — Belden 34920 is a 20 AWG stranded tinned copper lead wire with CSPE (chlorosulph...
- 34403 — Belden part 34403 is a 3 AWG (133x24) tinned copper lead wire with chlorosulphon...
- 7123WS — The Belden 7123WS is a high-flex, 3+1 conductor 16 AWG bare copper cable designe...
- 57004 — The Belden 57004 is a plenum-rated, shielded 4-conductor 24 AWG bare copper cabl...
1472A FAQ
What is 1472A?
1472A is a Bulk Wire Cable from Belden. The Belden 1472A is a UL-listed instrumentation cable designed for industrial control, DCS, and PLC systems. It features 36 pairs of 18 AWG and one 22 AWG bare copper conductors with PVC insulation, an overall Beldfoil shield, and a black PVC outer jacket. The cable is rated for 300V PLTC / 150V ITC applications and supports an operating temperature range of -30°C to +105°C.
Who manufactures 1472A?
1472A is manufactured by Belden.
Where can I download the 1472A datasheet PDF?
The 1472A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1472A specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 36 pairs of 18 AWG (7x26) and 1 comm wire of 22 AWG (7x30) bare copper |
| DC Resistance | Pair(s) 5.86 Ohm/1000ft, Comm wire(s) 14.7 Ohm/1000ft |
| Minimum bend radius | 10.9 in (277 mm) stationary and installation |
| Nominal overall diameter | 1.085 in (27.56 mm) |
| Operating temperature | -30°C to +105°C (UL temperature rating 105°C) |
| Outer jacket | Black PVC, nominal thickness 0.074 in (1.9 mm) |
| Outer shield | Bi-laminate (Alum+Poly) tape with 100% coverage and an 18 AWG (7x26) TC drainwire |
| Voltage rating | 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC) |