4546FLW Datasheet
The 4546FLW is a security and commercial audio cable consisting of 8 pairs of 22 AWG stranded bare copper conductors with Low Smoke Zero Halogen (LSZH) insulation, a Beldfoil shield, and an LSZH outer jacket with a ripcord. It is designed for use in security systems, intercom/PA systems, sound/audio systems, and power-limited controls. The cable features Euroclass Cca CPR compliance, indoor/outdoor suitability, and sunlight resistance for black jacket versions.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
4546FLW Key Specifications
- Max. Current
- 2 Amps per Conductor
- Nom. Capacitance Cond-to-Cond
- 105 pF/m (32.0 pF/ft)
- Nom. Capacitance Cond-to-Other (Conds + Shield)
- 185 pF/m (56.4 pF/ft)
- Operating Temperature
- -20°C To +70°C
- Conductor size
- 22 AWG, 7x30 stranded bare copper (BC)
- Installation Min. Bend Radius
- 100 mm (3.9 in)
- Max. Pull Tension
- 330 N (74 lbf)
- Nom. Conductor DCR
- 54 Ohm/km (16 Ohm/1000ft)
Characteristics (datasheet)
- Conductor size
- 22 AWG, 7x30 stranded bare copper (BC)
- Nom. Conductor DCR
- 54 Ohm/km (16 Ohm/1000ft)
- Nom. Capacitance Cond-to-Cond
- 105 pF/m (32.0 pF/ft)
- Nom. Capacitance Cond-to-Other (Conds + Shield)
- 185 pF/m (56.4 pF/ft)
- Max. Current
- 2 Amps per Conductor
- Nom Outer Shield DCR
- 42 Ohm/km (13 Ohm/1000ft)
- Operating Temperature
- -20°C To +70°C
- Installation Min. Bend Radius
- 100 mm (3.9 in)
- Max. Pull Tension
- 330 N (74 lbf)
4546FLW Applications
- Security Systems
- Intercom/PA Systems
- Sound/Audio Systems
- Power-Limited Controls
Other Belden parts
- 8845MN — The 8845MN is a SpaceMaker™ 5-conductor 16 AWG tinned copper cable with polyprop...
- 85618CY — The 85618CY is an XTRAGUARD FLEX continuous flex control cable featuring 18 cond...
- 77104 — The Belden 77104 is a 4-conductor 24 AWG tinned copper ECOCABLE with MPPE insula...
- 7965E — The Belden 7965E is a Category 6 Premise Horizontal Cable (250 MHz) with 4 pairs...
- 1191AM — The Belden 1191AM is a CATV video cable of RG6 type, featuring an 18 AWG solid b...
- 70069CH — The Belden 70069CH is a 2-pair AES/EBU digital audio cable with a 22AWG conducto...
- 21664 — The Belden 21664 is a 600 V TC-CIC tray cable with four 2 AWG bare copper conduc...
- 5074C — The Belden 5074C is a 4-conductor, 16 AWG tinned copper control cable with PVC i...
More Bulk Wire Cable
- 8646MN — The Belden 8646MN is a SpaceMaker™ 7-conductor 24AWG (10x34) tinned copper cable...
- 8628 — The Belden 8628 is a heavy-duty electronic cable featuring seven 14 AWG stranded...
- 9309 — The Belden 9309 is an audio, control, and instrument cable featuring 22 AWG soli...
- 28094A — The Belden 28094A is a 16-conductor, 14 AWG (7x22) bare copper power and control...
- 7787A — The Belden 7787A is a sub-miniature digital coax snake cable with a riser-CMR ra...
- 78341 — The Belden 78341 ECOCABLE is a high-performance multi-conductor cable featuring...
- 58120 — The Belden 58120 is a plenum-rated, 10-conductor 22 AWG shielded cable designed...
- 6178 — The Belden 6178 is a Teck90 600V/1000V cable featuring two 4/0 AWG bare copper c...
4546FLW FAQ
What is 4546FLW?
4546FLW is a Bulk Wire Cable from Belden. The 4546FLW is a security and commercial audio cable consisting of 8 pairs of 22 AWG stranded bare copper conductors with Low Smoke Zero Halogen (LSZH) insulation, a Beldfoil shield, and an LSZH outer jacket with a ripcord. It is designed for use in security systems, intercom/PA systems, sound/audio systems, and power-limited controls. The cable features Euroclass Cca CPR compliance, indoor/outdoor suitability, and sunlight resistance for black jacket versions.
Who manufactures 4546FLW?
4546FLW is manufactured by Belden.
Where can I download the 4546FLW datasheet PDF?
The 4546FLW datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 4546FLW specifications
Click to ask a quick question:
Parameters
| Conductor size | 22 AWG, 7x30 stranded bare copper (BC) |
| Installation Min. Bend Radius | 100 mm (3.9 in) |
| Max. Current | 2 Amps per Conductor |
| Max. Pull Tension | 330 N (74 lbf) |
| Nom. Capacitance Cond-to-Cond | 105 pF/m (32.0 pF/ft) |
| Nom. Capacitance Cond-to-Other (Conds + Shield) | 185 pF/m (56.4 pF/ft) |
| Nom. Conductor DCR | 54 Ohm/km (16 Ohm/1000ft) |
| Nom Outer Shield DCR | 42 Ohm/km (13 Ohm/1000ft) |
| Operating Temperature | -20°C To +70°C |