4381MD Datasheet
The 4381MD is a shielded OSDP reader cable designed for access control, OSDP readers, and RS-485 serial data applications. It features one 24 AWG stranded tinned copper data pair with foam PE insulation and a Beldfoil shield with drain, alongside two 18 AWG stranded bare copper power conductors with LSZH insulation. The assembly is protected by a low smoke zero halogen (LSZH) outer jacket, offering an operating temperature range of -30°C to +70°C and Euroclass Dca fire performance.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
4381MD Key Specifications
- Max Current (Data Pair)
- 3.8 Amps per Conductor at 25ºC
- Power Conductor Size
- 18 AWG 7x26 BC (Bare Copper)
- Operating Temperature
- -30°C To +70°C
- CPR Euroclass
- Dca-s1,d2,a1 (Dca)
- Data Conductor Size
- 24 AWG 7x32 TC (Tinned Copper)
- Data Pair Characteristic Impedance
- 120 Ohm
- Data Pair Conductor DCR
- 79 Ohm/km (24 Ohm/1000ft)
- Outer Jacket Nominal Diameter
- 6.5 mm (0.26 in)
Characteristics (datasheet)
- Data Conductor Size
- 24 AWG 7x32 TC (Tinned Copper)
- Power Conductor Size
- 18 AWG 7x26 BC (Bare Copper)
- Data Pair Characteristic Impedance
- 120 Ohm
- Max Current (Data Pair)
- 3.8 Amps per Conductor at 25ºC
- Operating Temperature
- -30°C To +70°C
- Outer Jacket Nominal Diameter
- 6.5 mm (0.26 in)
- CPR Euroclass
- Dca-s1,d2,a1 (Dca)
- Data Pair Conductor DCR
- 79 Ohm/km (24 Ohm/1000ft)
4381MD Applications
- OSDP Readers
- Serial Data
- Access Control
Other Belden parts
- 35716 — The Belden 35716 is a lead wire with a 16 AWG (19x29) stranded tinned copper con...
- 7430W — The Belden 7430W is a MachFlex™ high-flex cable designed for robotics and contin...
- 8233 — The Belden 8233 is a video triax cable of RG11 type, featuring a 14 AWG solid ba...
- 9182 — The Belden 9182 is a 150Ω twinaxial cable consisting of a single pair of 22 AWG...
- 1673A — The Belden 1673A is a conformable, unjacketed 50 Ohm coaxial cable (RG-402) feat...
- 80029 — The Belden 80029 is a 25-conductor, 20 AWG tinned copper control cable with modi...
- 9990 — The Belden 9990 is an audio, control, and instrument cable consisting of three i...
- 78062 — The Belden 78062 is a 2-pair 26 AWG tinned copper ECOCABLE with modified polyphe...
More Bulk Wire Cable
- 8810 — The Belden 8810 is an unshielded, 2-conductor 10 AWG speaker cable constructed w...
- 50001L — The Belden 50001L is an RS-485 fire resistant cable with one pair of 22 AWG stra...
- 83348E — The Belden 83348E is a high-temperature, 4-conductor electronic cable designed f...
- 78176 — The Belden 78176 is a 6-pair, 24 AWG tinned copper conductor cable (ECOCABLE) wi...
- 35493 — Belden 35493 is an XTRAGUARD 3 cable with 3 pairs of 24 AWG stranded tinned copp...
- 23548D — Belden 23548D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, contain...
- 45495 — The Belden 45495 is an XTRAGUARD 4 cable with 5 pairs of 24 AWG (7x32) stranded...
- 6357 — The Belden 6357 is a 9-conductor, 24 AWG tinned copper communication and control...
4381MD FAQ
What is 4381MD?
4381MD is a Bulk Wire Cable from Belden. The 4381MD is a shielded OSDP reader cable designed for access control, OSDP readers, and RS-485 serial data applications. It features one 24 AWG stranded tinned copper data pair with foam PE insulation and a Beldfoil shield with drain, alongside two 18 AWG stranded bare copper power conductors with LSZH insulation. The assembly is protected by a low smoke zero halogen (LSZH) outer jacket, offering an operating temperature range of -30°C to +70°C and Euroclass Dca fire performance.
Who manufactures 4381MD?
4381MD is manufactured by Belden.
Where can I download the 4381MD datasheet PDF?
The 4381MD datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 4381MD specifications
Click to ask a quick question:
Parameters
| CPR Euroclass | Dca-s1,d2,a1 (Dca) |
| Data Conductor Size | 24 AWG 7x32 TC (Tinned Copper) |
| Data Pair Characteristic Impedance | 120 Ohm |
| Data Pair Conductor DCR | 79 Ohm/km (24 Ohm/1000ft) |
| Max Current (Data Pair) | 3.8 Amps per Conductor at 25ºC |
| Operating Temperature | -30°C To +70°C |
| Outer Jacket Nominal Diameter | 6.5 mm (0.26 in) |
| Power Conductor Size | 18 AWG 7x26 BC (Bare Copper) |