BeldenBulk Wire Cable

Belden 38214 is a UL Type PV wire with a 14 AWG (41x30) tinned copper conductor, XLPO/XLPE thermoset insulation, and a PVC outer jacket. It is rated 600 V, 90 °C wet/dry, and is suited for interconnection wiring of grounded and ungrounded photovoltaic power systems per NEC Section 690.31(A). The cable is sunlight resistant and complies with PV, RHW-2, and USE-2 standards.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

38214 Key Specifications

Max. current
35 Amps single conductor in free air
UL voltage rating
600 V
UL temperature / operating temperature
90°C Wet/Dry; -40°C to +90°C
Bulk cable weight
36 lbs/1000ft (54 kg/km)
Conductor size / stranding / material
14 AWG, 41x30, tinned copper
Insulation material / nominal thickness
XLP, XLPO, XLPE (Thermoset), 0.048 in (1.2 mm)
Jacket material / nominal thickness / nominal diameter
PVC - Polyvinyl Chloride, 0.033 in (0.84 mm), 0.243 in (6.17 mm)
Max. pull tension
53.5 lbs (24.3 kg)

Characteristics (datasheet)

Conductor size / stranding / material
14 AWG, 41x30, tinned copper
Insulation material / nominal thickness
XLP, XLPO, XLPE (Thermoset), 0.048 in (1.2 mm)
Jacket material / nominal thickness / nominal diameter
PVC - Polyvinyl Chloride, 0.033 in (0.84 mm), 0.243 in (6.17 mm)
UL voltage rating
600 V
Max. current
35 Amps single conductor in free air
UL temperature / operating temperature
90°C Wet/Dry; -40°C to +90°C
Max. pull tension
53.5 lbs (24.3 kg)
Bulk cable weight
36 lbs/1000ft (54 kg/km)

38214 Applications

  • Interconnection wiring of grounded and ungrounded photovoltaic power systems

Other Belden parts

  • 5224C — The Belden 5224C is an XTRAGUARD 1 multi-conductor cable featuring 19 conductors...
  • 7807A — The Belden 7807A is a 50 Ohm wireless transmission coaxial cable of RG58 type, f...
  • 30816 — Belden part 30816 is a 16 AWG (26x30) stranded tinned copper lead wire with sili...
  • 8402 — The Belden 8402 is a ruggedized 2-conductor 20 AWG tinned copper microphone cabl...
  • 4281MDW — The Belden 4281MDW is an OSDP reader cable designed for access control, OSDP rea...
  • 83027 — The Belden 83027 is a high-temperature plastic lead wire featuring a 20 AWG stra...
  • 8918 — The Belden 8918 is a low-temperature plastic lead wire with an 18 AWG tinned cop...
  • 29545 — Belden 29545 is a flexible 3-conductor VFD motor supply cable built with 2/0 AWG...

More Bulk Wire Cable

  • 7962A — The Belden 7962A is an industrial Ethernet Cat 5e cable featuring a quad (two-pa...
  • 1811A — The Belden 1811A is a discontinued speaker cable consisting of eight 14 AWG stra...
  • 6001 — The Belden 6001 is a Teck90 1000V power and control cable featuring 3+G conducto...
  • 6408 — The Belden 6408 is a communication and control cable featuring 10 pairs of 24 AW...
  • 78449 — The Belden 78449 is an ECOCABLE consisting of 25 pairs of 22 AWG stranded tinned...
  • 9762MN — The Belden 9762MN SpaceMaker™ is a multi-pair cable consisting of five 16 AWG (6...
  • 9421 — The Belden 9421 is an 8-conductor, 22AWG tinned copper cable with PVC insulation...
  • 5284UE — The 5284UE is a PTZ (Control + Power) riser-CMR cable designed for surveillance,...

38214 FAQ

What is 38214?

38214 is a Bulk Wire Cable from Belden. Belden 38214 is a UL Type PV wire with a 14 AWG (41x30) tinned copper conductor, XLPO/XLPE thermoset insulation, and a PVC outer jacket. It is rated 600 V, 90 °C wet/dry, and is suited for interconnection wiring of grounded and ungrounded photovoltaic power systems per NEC Section 690.31(A). The cable is sunlight resistant and complies with PV, RHW-2, and USE-2 standards.

Who manufactures 38214?

38214 is manufactured by Belden.

Where can I download the 38214 datasheet PDF?

The 38214 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 38214 specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk cable weight36 lbs/1000ft (54 kg/km)
Conductor size / stranding / material14 AWG, 41x30, tinned copper
Insulation material / nominal thicknessXLP, XLPO, XLPE (Thermoset), 0.048 in (1.2 mm)
Jacket material / nominal thickness / nominal diameterPVC - Polyvinyl Chloride, 0.033 in (0.84 mm), 0.243 in (6.17 mm)
Max. current35 Amps single conductor in free air
Max. pull tension53.5 lbs (24.3 kg)
UL temperature / operating temperature90°C Wet/Dry; -40°C to +90°C
UL voltage rating600 V