38208 Datasheet
Belden 38208 is an 8 AWG UL Type PV wire with 133x29 stranded tinned copper conductor, XLPO/XLPE thermoset insulation, and a PVC outer jacket. It is rated 600 V, 90 °C wet/dry, sunlight resistant, and is intended for interconnection wiring of grounded and ungrounded photovoltaic power systems per NEC Section 690.31(A).
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
38208 Key Specifications
- Max. Current
- 80 Amps Single Conductor in Free Air
- UL Voltage Rating
- 600 V
- UL Temperature / Operating
- 90°C Wet/Dry / -40°C To +90°C
- Conductor size / stranding / material
- 8 AWG, 133x29, TC - Tinned Copper
- Insulation material / nominal thickness
- XLP, XLPO, XLPE (Thermoset), 0.063 in (1.6 mm)
- Max. Pull Tension / Bulk Cable Weight
- 213 lbs (96.6 kg) / 98 lbs/1000ft (150 kg/km)
- Nom. Conductor DCR
- 0.61 Ohm/1000ft (2.0 Ohm/km)
- Outer jacket material / thickness / nominal diameter
- PVC - Polyvinyl Chloride, 0.033 in (0.84 mm), 0.364 in (9.25 mm)
Characteristics (datasheet)
- Conductor size / stranding / material
- 8 AWG, 133x29, TC - Tinned Copper
- Insulation material / nominal thickness
- XLP, XLPO, XLPE (Thermoset), 0.063 in (1.6 mm)
- Outer jacket material / thickness / nominal diameter
- PVC - Polyvinyl Chloride, 0.033 in (0.84 mm), 0.364 in (9.25 mm)
- UL Voltage Rating
- 600 V
- Max. Current
- 80 Amps Single Conductor in Free Air
- Nom. Conductor DCR
- 0.61 Ohm/1000ft (2.0 Ohm/km)
- UL Temperature / Operating
- 90°C Wet/Dry / -40°C To +90°C
- Max. Pull Tension / Bulk Cable Weight
- 213 lbs (96.6 kg) / 98 lbs/1000ft (150 kg/km)
38208 Applications
- Interconnection wiring of grounded and ungrounded photovoltaic power systems (NEC Section 690.31(A))
Other Belden parts
- 972327100 — 1kV 1A PP Insulated Probe Lead, Black, -25°C to 80°C
- 29560C — Belden 29560C is a CSA TC rated VFD power cable with three 3/0 AWG bare copper c...
- 9154 — The Belden 9154 is a 2-conductor, 20 AWG tinned copper cable with PVC insulation...
- 1061A — The Belden 1061A is a 36-pair instrumentation and control cable featuring 20 AWG...
- 45451 — Belden part 45451 is an XTRAGUARD 4 single-pair cable with 20 AWG stranded tinne...
- 9473MN — The Belden 9473MN is a SpaceMaker™ shielded multi-conductor cable featuring seve...
- 5158C — The Belden 5158C is an XTRAGUARD 1 shielded multi-conductor cable featuring 8 co...
- 76703TS — The 76703TS is a MachFlex™ high-flexibility cable designed for continuous flexin...
More Bulk Wire Cable
- 7787A — The Belden 7787A is a sub-miniature digital coax snake cable with a riser-CMR ra...
- 58119 — The Belden 58119 is a plenum-rated communication and control cable featuring nin...
- 7046 — The Belden 7046 is a single-conductor, 14 AWG tinned copper hook-up wire with XL...
- 4101FE — The Belden 4101FE is a security and commercial audio cable featuring three 14 AW...
- 1737C — The Belden 1737C is a 3-conductor, 22 AWG tinned copper communication and contro...
- 1590 — The Belden 1590 is a heavy-duty TW-75 600V bulk cable featuring a single 1 AWG 1...
- 7897A — The part 7897A is a DeviceBus® 2-pair cable designed for ODVA DeviceNet™ device-...
- 25514D — The Belden 25514D is a Canadian instrumentation cable rated TC-ACIC 600 V, built...
38208 FAQ
What is 38208?
38208 is a Bulk Wire Cable from Belden. Belden 38208 is an 8 AWG UL Type PV wire with 133x29 stranded tinned copper conductor, XLPO/XLPE thermoset insulation, and a PVC outer jacket. It is rated 600 V, 90 °C wet/dry, sunlight resistant, and is intended for interconnection wiring of grounded and ungrounded photovoltaic power systems per NEC Section 690.31(A).
Who manufactures 38208?
38208 is manufactured by Belden.
Where can I download the 38208 datasheet PDF?
The 38208 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 38208 specifications
Click to ask a quick question:
Parameters
| Conductor size / stranding / material | 8 AWG, 133x29, TC - Tinned Copper |
| Insulation material / nominal thickness | XLP, XLPO, XLPE (Thermoset), 0.063 in (1.6 mm) |
| Max. Current | 80 Amps Single Conductor in Free Air |
| Max. Pull Tension / Bulk Cable Weight | 213 lbs (96.6 kg) / 98 lbs/1000ft (150 kg/km) |
| Nom. Conductor DCR | 0.61 Ohm/1000ft (2.0 Ohm/km) |
| Outer jacket material / thickness / nominal diameter | PVC - Polyvinyl Chloride, 0.033 in (0.84 mm), 0.364 in (9.25 mm) |
| UL Temperature / Operating | 90°C Wet/Dry / -40°C To +90°C |
| UL Voltage Rating | 600 V |