3254 Datasheet
The Belden 3254 is a single-conductor, 16 AWG tinned copper hook-up wire with semi-rigid PVC insulation, rated for a voltage of 300 V and an operating temperature range of -10°C to +80°C. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, control panels, automation equipment, and instrumentation systems. The wire meets AWM/STYLE 1061, VW-1, and CSA AWM I A/B standards, and is available in multiple color codes and lengths.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
3254 Key Specifications
- Nom. inductance
- 0.03 µH/ft (0.098 µH/m)
- Voltage rating
- 300 V (AWM 1061 / CSA AWM)
- Operating temperature
- -10°C To +80°C (UL Temperature: 80°C)
- Conductor material
- TC - Tinned Copper
- Conductor size
- 16 AWG (7/24)
- Insulation material
- SR-PVC - Polyvinyl Chloride (Semi-Rigid)
- Max. pull tension
- 8.4 lbs (3.8 kg)
- Min. stationary bend radius
- 0.8 in (20 mm)
Characteristics (datasheet)
- Conductor size
- 16 AWG (7/24)
- Conductor material
- TC - Tinned Copper
- Insulation material
- SR-PVC - Polyvinyl Chloride (Semi-Rigid)
- Nominal insulation thickness
- 0.010 in (0.25 mm)
- Nominal overall diameter
- 0.080 in (2.0 mm)
- Voltage rating
- 300 V (AWM 1061 / CSA AWM)
- Operating temperature
- -10°C To +80°C (UL Temperature: 80°C)
- Max. pull tension
- 8.4 lbs (3.8 kg)
- Min. stationary bend radius
- 0.8 in (20 mm)
- Nom. inductance
- 0.03 µH/ft (0.098 µH/m)
3254 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 85207CY — The 85207CY is a 7-conductor, 12 AWG XTRAGUARD FLEX continuous flex control cabl...
- 37104 — Belden part 37104 is a 4 AWG rubber lead wire with a tinned copper conductor (10...
- 6381 — The Belden 6381 is a communication and control cable consisting of 12 pairs of 2...
- 79060 — The Belden 79060 is an 8-conductor, 26 AWG tinned copper cable with modified pol...
- 1467A — The Belden 1467A is an UL-listed instrumentation cable featuring 8 pairs of 18 A...
- 80127 — The Belden 80127 (Alpha Wire P/N 80127) is an 18-conductor, 20 AWG tinned copper...
- 1518C — The Belden 1518C is a discontinued audio snake cable featuring 32 pairs of 24 AW...
- 5283C — The Belden 5283C is an XTRAGUARD 1 multi-conductor cable featuring 3 pairs of 20...
More Bulk Wire Cable
- 9182 — The Belden 9182 is a 150Ω twinaxial cable consisting of a single pair of 22 AWG...
- 1073A — The Belden 1073A is a UL-listed instrumentation cable featuring 16 pairs of 16 A...
- 9559 — The Belden 9559 is a high-performance instrumentation cable featuring 9 pairs of...
- 1557 — The Belden 1557 is a single-conductor hook-up wire constructed of 16 AWG tinned...
- 77254 — Belden 77254 is a 4-conductor, 28 AWG (7x36 stranded tinned copper) ECOCABLE wit...
- 28630A — The Belden 28630A is a 37-conductor, 12 AWG (7x20 stranded bare copper) UL Type...
- 80054 — The Belden 80054 is a 5-conductor, 14 AWG tinned copper cable with mPPE insulati...
- 3047 — The Belden 3047 is a single-conductor hook-up wire featuring a 30 AWG tinned cop...
3254 FAQ
What is 3254?
3254 is a Bulk Wire Cable from Belden. The Belden 3254 is a single-conductor, 16 AWG tinned copper hook-up wire with semi-rigid PVC insulation, rated for a voltage of 300 V and an operating temperature range of -10°C to +80°C. It is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, control panels, automation equipment, and instrumentation systems. The wire meets AWM/STYLE 1061, VW-1, and CSA AWM I A/B standards, and is available in multiple color codes and lengths.
Who manufactures 3254?
3254 is manufactured by Belden.
Where can I download the 3254 datasheet PDF?
The 3254 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 3254 specifications
Click to ask a quick question:
Parameters
| Conductor material | TC - Tinned Copper |
| Conductor size | 16 AWG (7/24) |
| Insulation material | SR-PVC - Polyvinyl Chloride (Semi-Rigid) |
| Max. pull tension | 8.4 lbs (3.8 kg) |
| Min. stationary bend radius | 0.8 in (20 mm) |
| Nominal insulation thickness | 0.010 in (0.25 mm) |
| Nominal overall diameter | 0.080 in (2.0 mm) |
| Nom. inductance | 0.03 µH/ft (0.098 µH/m) |
| Operating temperature | -10°C To +80°C (UL Temperature: 80°C) |
| Voltage rating | 300 V (AWM 1061 / CSA AWM) |