29500 Datasheet
Belden 29500 is a flexible 600 V motor supply cable (TC-ER, WTTC) intended for variable frequency drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations. It has three 16 AWG stranded tinned copper conductors with XLPE insulation plus a 16 AWG PVC-insulated ground and an uninsulated 16 AWG ground wire, with overall Beldfoil and 85% tinned copper braid shielding under a black PVC jacket. It is rated 90°C dry and wet, sunlight resistant, suitable for direct burial, and has a nominal overall diameter of 0.534 in (13.6 mm).
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
29500 Key Specifications
- Maximum current
- 18 Amps per conductor at 30°C
- Nominal capacitance
- 23 pF/ft (75 pF/m) conductor-to-conductor; 48 pF/ft (160 pF/m) conductor-to-other (conds + shield)
- Voltage rating
- 600 V RMS (Type TC) (TC-ER, WTTC, UL Flexible Motor Supply Cable); 600 V (C(UL) CIC TC); 1000 V (AWM I/II A/B)
- Temperature rating
- UL: 90°C Dry, 90°C Wet; Operating: -40°C to +90°C
- Conductors
- 3 x 16 AWG (26x30) stranded tinned copper + 16 AWG (26x30) TC insulated ground + 16 AWG (26x30) TC uninsulated ground wire
- Maximum pull tension
- 256 lbs (116 kg)
- Nominal conductor DCR
- 3.91 Ohm/1000ft (12.8 Ohm/km)
- Overall cable diameter (nominal)
- 0.534 in (13.6 mm)
Characteristics (datasheet)
- Voltage rating
- 600 V RMS (Type TC) (TC-ER, WTTC, UL Flexible Motor Supply Cable); 600 V (C(UL) CIC TC); 1000 V (AWM I/II A/B)
- Temperature rating
- UL: 90°C Dry, 90°C Wet; Operating: -40°C to +90°C
- Conductors
- 3 x 16 AWG (26x30) stranded tinned copper + 16 AWG (26x30) TC insulated ground + 16 AWG (26x30) TC uninsulated ground wire
- Nominal conductor DCR
- 3.91 Ohm/1000ft (12.8 Ohm/km)
- Nominal capacitance
- 23 pF/ft (75 pF/m) conductor-to-conductor; 48 pF/ft (160 pF/m) conductor-to-other (conds + shield)
- Maximum current
- 18 Amps per conductor at 30°C
- Overall cable diameter (nominal)
- 0.534 in (13.6 mm)
- Maximum pull tension
- 256 lbs (116 kg)
29500 Applications
- Variable Frequency Drives (VFD)
- AC Motor and Drive Systems
- Class 1 Division 2 Hazardous Locations
Other Belden parts
- 6075 — The Belden 6075 is a Teck90 600V cable designed for CEC power and control applic...
- 6163 — The Belden 6163 is a Teck90 1000V cable with 3+G bare copper conductors (3/0+6 A...
- 70084 — The Belden 70084 is a 75 Ohm SDI coaxial cable (RG-11 type) featuring a 14 AWG s...
- 78458 — The Belden 78458 is a high-performance 25-pair 24 AWG tinned copper communicatio...
- 1705 — The Belden 1705 is a single-conductor communication and control cable designed f...
- 1728 — The Belden 1728 is a multi-conductor communication and control cable featuring 2...
- 28150A — The Belden 28150A is a UL Type TC (1277) power and control cable rated for 600 V...
- 5665 — The Belden 5665 is a 4-conductor, 6 AWG XTRAGUARD motor supply cable with bare c...
More Bulk Wire Cable
- 5311C — The 5311C is an XTRAGUARD 1 shielded multi-conductor cable featuring 7 conductor...
- 9514 — The Belden 9514 is a high-performance instrumentation cable consisting of 4 pair...
- 8434 — The Belden 8434 is an electronic cable with one pair and two conductors of 25AWG...
- 7961A — The 7961A is an Industrial Ethernet Cat 5e cable consisting of one quad (two pai...
- 7131 — The Belden 7131 is a single-conductor, 22 AWG tinned copper hook-up wire with ir...
- 78226 — The Belden 78226 is an ECOCABLE consisting of 6 pairs of 24 AWG tinned copper co...
- 65243CY — The Belden 65243CY is a flexible 3-conductor 24 AWG control cable rated for 600...
- 78146 — The Belden 78146 is a 6-conductor, 20 AWG tinned copper cable with modified poly...
29500 FAQ
What is 29500?
29500 is a Bulk Wire Cable from Belden. Belden 29500 is a flexible 600 V motor supply cable (TC-ER, WTTC) intended for variable frequency drives (VFD), AC motor and drive systems, and Class 1 Division 2 hazardous locations. It has three 16 AWG stranded tinned copper conductors with XLPE insulation plus a 16 AWG PVC-insulated ground and an uninsulated 16 AWG ground wire, with overall Beldfoil and 85% tinned copper braid shielding under a black PVC jacket. It is rated 90°C dry and wet, sunlight resistant, suitable for direct burial, and has a nominal overall diameter of 0.534 in (13.6 mm).
Who manufactures 29500?
29500 is manufactured by Belden.
Where can I download the 29500 datasheet PDF?
The 29500 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 29500 specifications
Click to ask a quick question:
Parameters
| Conductors | 3 x 16 AWG (26x30) stranded tinned copper + 16 AWG (26x30) TC insulated ground + 16 AWG (26x30) TC uninsulated ground wire |
| Maximum current | 18 Amps per conductor at 30°C |
| Maximum pull tension | 256 lbs (116 kg) |
| Nominal capacitance | 23 pF/ft (75 pF/m) conductor-to-conductor; 48 pF/ft (160 pF/m) conductor-to-other (conds + shield) |
| Nominal conductor DCR | 3.91 Ohm/1000ft (12.8 Ohm/km) |
| Overall cable diameter (nominal) | 0.534 in (13.6 mm) |
| Temperature rating | UL: 90°C Dry, 90°C Wet; Operating: -40°C to +90°C |
| Voltage rating | 600 V RMS (Type TC) (TC-ER, WTTC, UL Flexible Motor Supply Cable); 600 V (C(UL) CIC TC); 1000 V (AWM I/II A/B) |