28340A Datasheet

BeldenBulk Wire Cable

The Belden 28340A is a 9-conductor, 16 AWG (7x24) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is UL Type TC rated at 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.449 in (11.4 mm) and a wet/dry operating temperature range of -30°C to 90°C.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

28340A Key Specifications

Maximum current
12.6 Amps per Conductor at 30ºC
UL voltage rating
600 V (TC-ER), 150 V (NPLF)
Operating temperature
Wet/Dry: -30°C to 90°C (UL: 90°C Dry, 90°C Wet)
Conductor
9 x 16 AWG, 7x24 stranding, bare copper
Insulation
PVC/Nylon, nominal thickness 0.020 in (0.51 mm)
Nominal conductor DCR
4.2 Ohm/1000ft
Outer jacket
Black PVC, nominal thickness 0.047 in (1.2 mm), ripcord: Yes
Overall cable diameter (nominal)
0.449 in (11.4 mm)

Characteristics (datasheet)

Conductor
9 x 16 AWG, 7x24 stranding, bare copper
Insulation
PVC/Nylon, nominal thickness 0.020 in (0.51 mm)
Outer jacket
Black PVC, nominal thickness 0.047 in (1.2 mm), ripcord: Yes
Overall cable diameter (nominal)
0.449 in (11.4 mm)
Nominal conductor DCR
4.2 Ohm/1000ft
Maximum current
12.6 Amps per Conductor at 30ºC
UL voltage rating
600 V (TC-ER), 150 V (NPLF)
Operating temperature
Wet/Dry: -30°C to 90°C (UL: 90°C Dry, 90°C Wet)

28340A Applications

  • Power and Control Applications up to 600V
  • Class 1 Division 2 Hazardous Locations

Other Belden parts

  • 9512 — The Belden 9512 is a high-performance instrumentation cable containing two 22 AW...
  • 5382C — The Belden 5382C is a 2-conductor, 18 AWG tinned copper shielded cable with a sl...
  • 973889100 — 15A 300V Clip-On Probe Lead with Nickel Plating and Polyamide Insulation
  • 934066102 — HIRSCHMANN TEST AND MEASUREMENT 934066102 Test Lead, 4mm Bana...
  • 89259 — The Belden 89259 is a 75 Ohm analog video coaxial cable of RG-59 type, built wit...
  • 83049 — The Belden 83049 is a high-temperature plastic lead wire featuring a 22 AWG silv...
  • 86603CY — The Belden 86603CY is an XTRAGUARD FLEX continuous flex data cable with three 24...
  • 934062102 — HIRSCHMANN TEST AND MEASUREMENT 934062102 TEST LEAD, BLUE, 1M, 60V, 16A

More Bulk Wire Cable

  • 29021 — The Belden 29021 is a Canadian Instrumentation Cable (TC-ACIC) rated for 600 V p...
  • 3043A — The Belden 3043A is a UL-listed instrumentation cable consisting of two 16 AWG p...
  • 79207 — The 79207 is a 12-conductor, 20 AWG stranded tinned copper cable with mPPE insul...
  • 7897A — The part 7897A is a DeviceBus® 2-pair cable designed for ODVA DeviceNet™ device-...
  • 77224 — The Belden 77224 is a 4-conductor, 16 AWG stranded tinned copper cable with mPPE...
  • 1829A — The 1829A is a Series 6 broadband coaxial cable designed for CATV, broadband, RF...
  • 78449 — The Belden 78449 is an ECOCABLE consisting of 25 pairs of 22 AWG stranded tinned...
  • 2101A — The Belden 2101A is a 2-pair 18AWG tinned copper fieldbus cable with XLPO insula...

28340A FAQ

What is 28340A?

28340A is a Bulk Wire Cable from Belden. The Belden 28340A is a 9-conductor, 16 AWG (7x24) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is UL Type TC rated at 600 V (TC-ER) and 150 V (NPLF), suitable for power and control applications up to 600 V and Class 1 Division 2 hazardous locations. The cable has a nominal overall diameter of 0.449 in (11.4 mm) and a wet/dry operating temperature range of -30°C to 90°C.

Who manufactures 28340A?

28340A is manufactured by Belden.

Where can I download the 28340A datasheet PDF?

The 28340A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 28340A specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor9 x 16 AWG, 7x24 stranding, bare copper
InsulationPVC/Nylon, nominal thickness 0.020 in (0.51 mm)
Maximum current12.6 Amps per Conductor at 30ºC
Nominal conductor DCR4.2 Ohm/1000ft
Operating temperatureWet/Dry: -30°C to 90°C (UL: 90°C Dry, 90°C Wet)
Outer jacketBlack PVC, nominal thickness 0.047 in (1.2 mm), ripcord: Yes
Overall cable diameter (nominal)0.449 in (11.4 mm)
UL voltage rating600 V (TC-ER), 150 V (NPLF)