2622 Datasheet

BeldenBulk Wire Cable

The Belden 2622 is a single-conductor hook-up wire featuring 22 AWG nickel-plated copper conductor with PFA fluoroplastic insulation. It is rated for a voltage of 600 V and supports a wide operating temperature range from -150°C to +300°C. This high-performance wire is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

2622 Key Specifications

Nominal Inductance
0.04 µH/ft (0.13 µH/m)
Voltage Rating
600 V (AWM 11905, AWM 11540)
Operating Temperature Range
-150°C To +300°C (UL Temperature: 300°C)
Conductor Size
22 AWG (19/34) Nickel Plated Copper / Nickel Alloy
Insulation Material
PFA - Perfluoroalkoxy, Nom. Thickness 0.007 in (0.18 mm)
Max Pull Tension
27 lbs (12 kg)
Min. Bend Radius (Stationary)
0.4 in (10 mm)
Overall Cable Diameter (Nominal)
0.044 in (1.1 mm)

Characteristics (datasheet)

Voltage Rating
600 V (AWM 11905, AWM 11540)
Conductor Size
22 AWG (19/34) Nickel Plated Copper / Nickel Alloy
Insulation Material
PFA - Perfluoroalkoxy, Nom. Thickness 0.007 in (0.18 mm)
Operating Temperature Range
-150°C To +300°C (UL Temperature: 300°C)
Nominal Inductance
0.04 µH/ft (0.13 µH/m)
Overall Cable Diameter (Nominal)
0.044 in (1.1 mm)
Max Pull Tension
27 lbs (12 kg)
Min. Bend Radius (Stationary)
0.4 in (10 mm)

2622 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking
  • Serial communication
  • Control panels
  • Automation equipment
  • Instrumentation systems

Other Belden parts

  • 45463 — Belden part 45463 is an XTRAGUARD 4 multi-conductor cable with 3 conductors of 2...
  • 79015 — The Belden 79015 is an ECOFLEX multi-conductor cable featuring nine 18 AWG tinne...
  • 39112 — Belden 39112 is a 12 AWG (65x30) stranded tinned copper lead wire with PPO (poly...
  • 8453 — The Belden 8453 is a portable cordage cable featuring three 18 AWG stranded tinn...
  • 77220 — The Belden 77220 is a high-performance 15-conductor multi-conductor cable (ECOCA...
  • 7939A — The Belden 7939A is an Industrial Ethernet Cat 5e cable featuring 4 bonded pairs...
  • 6321 — The Belden 6321 is a shielded, 7-pair communication and control cable constructe...
  • 1816P — The Belden 1816P is a plenum-rated (CMP) audio snake cable designed for multi-ch...

More Bulk Wire Cable

  • 34490 — Belden part 34490 is a 1/0 AWG tinned copper lead wire with chlorosulphonated po...
  • 28600A — The Belden 28600A is a 6-conductor 18 AWG (7x26) bare copper cable with PVC/nylo...
  • 3532 — The Belden 3532 is a multi-conductor hook-up wire consisting of 20 individually...
  • 28605A — The Belden 28605A is a UL Type TC (1277) power and control cable with 15 bare co...
  • 9464 — The Belden 9464 is a 2-conductor, 20AWG tinned copper electronic cable featuring...
  • 9844 — The Belden 9844 is a 4-pair 24 AWG tinned copper cable with PE insulation and ov...
  • 83915 — The Belden 83915 is a Type E thermocouple cable consisting of a single pair of 2...
  • 7949A — The Belden 7949A is a composite cable designed for data, audio, video, security,...

2622 FAQ

What is 2622?

2622 is a Bulk Wire Cable from Belden. The Belden 2622 is a single-conductor hook-up wire featuring 22 AWG nickel-plated copper conductor with PFA fluoroplastic insulation. It is rated for a voltage of 600 V and supports a wide operating temperature range from -150°C to +300°C. This high-performance wire is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems.

Who manufactures 2622?

2622 is manufactured by Belden.

Where can I download the 2622 datasheet PDF?

The 2622 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 2622 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor Size22 AWG (19/34) Nickel Plated Copper / Nickel Alloy
Insulation MaterialPFA - Perfluoroalkoxy, Nom. Thickness 0.007 in (0.18 mm)
Max Pull Tension27 lbs (12 kg)
Min. Bend Radius (Stationary)0.4 in (10 mm)
Nominal Inductance0.04 µH/ft (0.13 µH/m)
Operating Temperature Range-150°C To +300°C (UL Temperature: 300°C)
Overall Cable Diameter (Nominal)0.044 in (1.1 mm)
Voltage Rating600 V (AWM 11905, AWM 11540)