The Belden 2216C is a semi-rigid communication and control cable featuring 6 pairs of 22 AWG stranded tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for a voltage of 150 V (AWM 2576) or 300 V (CM, CMG) and supports an operating temperature range of -20°C to +80°C. This cable is designed for industrial control systems, instrumentation circuits, PLC and DCS systems, and connecting sensors, encoders, solenoids, valves, actuators, and positioners carrying analog or digital signals.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2216C Key Specifications
- Nom. Capacitance Cond-to-Cond
- 24.2 pF/ft (79.4 pF/m)
- Nom. Capacitance Cond-to-Other
- 44 pF/ft (140 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
- UL Voltage Rating
- 150 V (AWM 2576), 300 V (CM, CMG)
- Operating Temperature
- -20°C to +80°C (UL Temperature: 80°C)
- Conductor
- 6 pairs, 22 AWG 7x30 TC - Tinned Copper
- Insulation Material
- SR-PVC - Polyvinyl Chloride (Semi-Rigid), nominal thickness 0.010 in (0.25 mm)
- Max. Pull Tension
- 58 lbs (26 kg)
2216C Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 2216C 6PR 22 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2576 --- LLXXXXXX CSA TYPE CMG FT4 CE ROHS · package Slate PVC jacket, supplied on Reel (100 ft, 500 ft, or 1,000 ft lengths)
Characteristics (datasheet)
- Conductor
- 6 pairs, 22 AWG 7x30 TC - Tinned Copper
- Insulation Material
- SR-PVC - Polyvinyl Chloride (Semi-Rigid), nominal thickness 0.010 in (0.25 mm)
- Outer Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, with 22 AWG (7x30) TC drainwire
- Outer Jacket
- Slate PVC, nominal thickness 0.032 in (0.81 mm), nominal diameter 0.315 in (8.00 mm)
- Nominal Characteristic Impedance
- 78 Ohm
- Nom. Capacitance Cond-to-Cond
- 24.2 pF/ft (79.4 pF/m)
- Nom. Capacitance Cond-to-Other
- 44 pF/ft (140 pF/m)
- Nom. Inductance
- 0.18 µH/ft (0.59 µH/m)
Absolute Maximum Ratings
- UL Voltage Rating
- 150 V (AWM 2576), 300 V (CM, CMG)
- Operating Temperature
- -20°C to +80°C (UL Temperature: 80°C)
- Max. Pull Tension
- 58 lbs (26 kg)
- Min. Bend Radius (Stationary)
- 3.1 in (79 mm)
2216C Applications
- Industrial control systems, raceways, cable trays, and ducts
- Instrumentation and control circuits
- Analog and digital signals (4–20 mA, 0–10 V)
- PLC and DCS systems
- Sensors, encoders, solenoids, valves, actuators, and positioners
Other Belden parts
- 9953 — The Belden 9953 is a high-shielded, 3-conductor 16 AWG tinned copper cable with...
- 88125 — The Belden 88125 is a computer EIA RS-232/422 cable designed for extreme high te...
- 5299C — The Belden 5299C is an XTRAGUARD 1 shielded cable consisting of 9 pairs of 20 AW...
- 2124A — The Belden 2124A is a high-performance fieldbus cable featuring 20 pairs of 18AW...
- 5116C — The Belden 5116C is a shielded, semi-rigid multi-conductor cable featuring six 2...
- 79235 — The Belden 79235 is a high-flexibility, 7-conductor 12 AWG cable with tinned cop...
- 80104 — The Belden 80104 is a flexible, shielded 3-conductor 26 AWG tinned copper cable...
- 50021L — The Belden 50021L is a fire-resistant RS-485 cable with one 20 AWG stranded tinn...
More Bulk Wire Cable
- 80151 — The Belden 80151 (ECOFLEX PUR) is a heavy-duty, zero-halogen flexible cable feat...
- 34401 — The Belden 34401 is a 1 AWG (210x24) stranded tinned copper lead wire with CSPE...
- 5452C — The Belden 5452C is a 2-pair, 20 AWG tinned copper cable with PVC insulation, an...
- 5857 — The Belden 5857 is a single-conductor 18 AWG silver-plated copper hook-up wire w...
- 78341 — The Belden 78341 ECOCABLE is a high-performance multi-conductor cable featuring...
- 6401 — The Belden 6401 is a shielded communication and control cable featuring two pair...
- 6288US — The 6288US is a plenum-rated (CMP) Siamese PTZ (Control + Power) cable designed...
- 5302C — The Belden 5302C is a heavy-duty, shielded multi-conductor cable featuring 12 st...
2216C FAQ
What is 2216C?
2216C is a Bulk Wire Cable from Belden. The Belden 2216C is a semi-rigid communication and control cable featuring 6 pairs of 22 AWG stranded tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for a voltage of 150 V (AWM 2576) or 300 V (CM, CMG) and supports an operating temperature range of -20°C to +80°C. This cable is designed for industrial control systems, instrumentation circuits, PLC and DCS systems, and connecting sensors, encoders, solenoids, valves, actuators, and positioners carrying analog or digital signals.
Who manufactures 2216C?
2216C is manufactured by Belden.
What is the marking code of 2216C?
According to its datasheet, 2216C in Slate PVC jacket, supplied on Reel (100 ft, 500 ft, or 1,000 ft lengths) is marked "Alpha Wire -* P/N 2216C 6PR 22 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2576 --- LLXXXXXX CSA TYPE CMG FT4 CE ROHS".
Where can I download the 2216C datasheet PDF?
The 2216C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2216C specifications
Click to ask a quick question:
Parameters
| Conductor | 6 pairs, 22 AWG 7x30 TC - Tinned Copper |
| Insulation Material | SR-PVC - Polyvinyl Chloride (Semi-Rigid), nominal thickness 0.010 in (0.25 mm) |
| Max. Pull Tension | 58 lbs (26 kg) |
| Min. Bend Radius (Stationary) | 3.1 in (79 mm) |
| Nom. Capacitance Cond-to-Cond | 24.2 pF/ft (79.4 pF/m) |
| Nom. Capacitance Cond-to-Other | 44 pF/ft (140 pF/m) |
| Nominal Characteristic Impedance | 78 Ohm |
| Nom. Inductance | 0.18 µH/ft (0.59 µH/m) |
| Operating Temperature | -20°C to +80°C (UL Temperature: 80°C) |
| Outer Jacket | Slate PVC, nominal thickness 0.032 in (0.81 mm), nominal diameter 0.315 in (8.00 mm) |
| Outer Shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, with 22 AWG (7x30) TC drainwire |
| UL Voltage Rating | 150 V (AWM 2576), 300 V (CM, CMG) |