The Belden 2124A is a high-performance fieldbus cable featuring 20 pairs of 18AWG tinned copper conductors with XLPO insulation, individual and overall Beldfoil shields, and a rugged TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. The cable is rated for 600 V, supports a maximum current of 5.4 Amps per conductor, and operates within a temperature range of -40°C to 90°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
2124A Key Specifications
- Max. Current
- 5.4 Amps per Conductor
- Max Current per Conductor
- 5.4 Amps
- Nominal Capacitance (Cond-to-Cond)
- 22 pF/ft (72 pF/m)
- UL Voltage Rating
- 600 V
- Voltage Rating
- 600 V
- Operating Temperature
- -40°C to 90°C
- Operating Temperature Range
- -40°C to 90°C
- UL Temperature
- 90°C
Characteristics (datasheet)
- Voltage Rating
- 600 V
- Conductor Configuration
- 20 pairs, 18 AWG (7x26) tinned copper
- Characteristic Impedance
- 100 Ohm nominal
- Operating Temperature Range
- -40°C to 90°C
- Max Current per Conductor
- 5.4 Amps
- Nominal Capacitance (Cond-to-Cond)
- 22 pF/ft (72 pF/m)
- Max Pull Tension
- 1170 lbs (531 kg)
- Bulk Cable Weight
- 734 lbs/1000ft (1090 kg/km)
Absolute Maximum Ratings
- UL Voltage Rating
- 600 V
- Max. Current
- 5.4 Amps per Conductor
- Max. Pull Tension
- 1170 lbs (531 kg)
- UL Temperature
- 90°C
- Operating Temperature
- -40°C to 90°C
2124A Applications
- Harsh environment digital and serial two-way communication
- Oil and gas extraction and refining sites
- Petrochemical applications
- Profibus process automation
- Foundation FieldBus process automation
- Extreme temperature environments
- Environments with exposure to humidity/moisture, dust, and oil
- Remote locations long distance applications
Other Belden parts
- 80021 — The Belden 80021 (ECOFLEX PUR) is a 3-conductor, 20 AWG tinned copper cable with...
- 78219 — The Belden 78219 is a multi-pair ECOCABLE consisting of 9 pairs of 26 AWG strand...
- 6372 — The Belden 6372 is a multi-pair communication and control cable featuring 25 pai...
- 5062C — The Belden 5062C is an XTRAGUARD 1, 2-conductor, 18 AWG tinned copper cable with...
- 9318 — The Belden 9318 is a high-performance instrumentation cable consisting of a sing...
- 75034 — The Belden 75034 is a high-flex Category 5e shielded twisted pair cable with two...
- 78123 — The Belden 78123 is a 3-conductor, 24 AWG tinned copper ECOCABLE with modified p...
- 930126104 — HIRSCHMANN TEST AND MEASUREMENT 930126104 ALLIGATOR CLIP, GREEN, AK 2 S
More Bulk Wire Cable
- 9984 — The Belden 9984 is a low-temperature plastic lead wire with a 24AWG (7x32) tinne...
- 79235 — The Belden 79235 is a high-flexibility, 7-conductor 12 AWG cable with tinned cop...
- 79045 — The Belden 79045 is an ECOFLEX 3-conductor 22 AWG tinned copper cable with MPPE...
- 8469 — The Belden 8469 is a 9-conductor, 18 AWG tinned copper electronic cable with PVC...
- 9815 — The Belden 9815 is a 100 Ohm twinaxial cable designed specifically for direct bu...
- 9616 — The Belden 9616 is a 15-conductor 24 AWG stranded tinned copper computer EIA RS-...
- 78158 — The Belden 78158 is an 8-pair, 28 AWG tinned copper conductor cable (ECOCABLE) w...
- 1655 — The Belden 1655 is a single-conductor 8 AWG tinned copper hook-up wire with PVC...
2124A FAQ
What is 2124A?
2124A is a Bulk Wire Cable from Belden. The Belden 2124A is a high-performance fieldbus cable featuring 20 pairs of 18AWG tinned copper conductors with XLPO insulation, individual and overall Beldfoil shields, and a rugged TPE outer jacket. It is designed for harsh environment digital and serial two-way communication, widely used in oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. The cable is rated for 600 V, supports a maximum current of 5.4 Amps per conductor, and operates within a temperature range of -40°C to 90°C.
Who manufactures 2124A?
2124A is manufactured by Belden.
Where can I download the 2124A datasheet PDF?
The 2124A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 2124A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 734 lbs/1000ft (1090 kg/km) |
| Characteristic Impedance | 100 Ohm nominal |
| Conductor Configuration | 20 pairs, 18 AWG (7x26) tinned copper |
| Max. Current | 5.4 Amps per Conductor |
| Max Current per Conductor | 5.4 Amps |
| Max Pull Tension | 1170 lbs (531 kg) |
| Max. Pull Tension | 1170 lbs (531 kg) |
| Nominal Capacitance (Cond-to-Cond) | 22 pF/ft (72 pF/m) |
| Operating Temperature | -40°C to 90°C |
| Operating Temperature Range | -40°C to 90°C |
| UL Temperature | 90°C |
| UL Voltage Rating | 600 V |
| Voltage Rating | 600 V |