1334A Datasheet
The Belden 1334A is a 1-pair 18AWG tinned copper fieldbus cable with polypropylene insulation, overall Beldfoil and tinned copper braid shield, and an orange PVC outer jacket. It is designed for harsh environment digital and serial two-way communication, including oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. The cable supports extreme temperature environments and long-distance remote location applications.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1334A Key Specifications
- Max. Capacitance Unbalance
- 1.2 pF/ft
- Max. Current
- 5.2 Amps per Conductor
- Nom. Capacitance Cond-to-Shield
- 45 pF/ft (150 pF/m)
- UL Voltage Rating
- 300 V RMS
- Operating Temperature
- -40°C to +105°C
- UL Temperature
- 90°C
- Bulk Cable Weight
- 60 lbs/1000ft
- Installation Min. Bend Radius
- 3.37 in (85.6 mm)
Characteristics (datasheet)
- Nom. Conductor DCR
- 7.2 Ohm/1000ft
- Nom. Capacitance Cond-to-Shield
- 45 pF/ft (150 pF/m)
- Max. Capacitance Unbalance
- 1.2 pF/ft
- Nom. Characteristic Impedence
- 100 Ohm
- Nom. Velocity of Prop.
- 66%
- Max. Current
- 5.2 Amps per Conductor
- Nom Outer Shield DCR
- 3.8 Ohm/1000ft (12 Ohm/km)
- Nom. Insertion Loss (Attenuation)
- 0.069 dB/100ft
- UL Voltage Rating
- 300 V RMS
- UL Temperature
- 90°C
- Operating Temperature
- -40°C to +105°C
- Stationary Min. Bend Radius
- 3.37 in (85.6 mm)
- Installation Min. Bend Radius
- 3.37 in (85.6 mm)
- Max. Pull Tension
- 44.8 lbs (20.3 kg)
- Bulk Cable Weight
- 60 lbs/1000ft
1334A Applications
- harsh environment digital and serial two-way communication
- oil and gas extraction and refining sites
- petrochemical
- Profibus process automation
- Foundation FieldBus process automation
- extreme temperature environments
- exposure to humidity/moisture, dust, and oil
- remote locations long distance applications
Other Belden parts
- 45112 — Belden 45112 is an XTRAGUARD 4 cable with two 24 AWG (7x32) tinned copper conduc...
- 8881MN — The Belden 8881MN is a SpaceMaker™ multi-conductor cable featuring 15 conductors...
- 934091101 — HIRSCHMANN TEST AND MEASUREMENT 934091101 TEST LEAD, RED, 500MM, 60V, 16A
- 3030A — The Belden 3030A is a UL-listed instrumentation and control cable featuring four...
- 6348 — The Belden 6348 is a 25-conductor, 22 AWG tinned copper communication and contro...
- 4641FDW — The Belden 4641FDW is an active, halogen-free instrumentation and computer cable...
- 1073A — The Belden 1073A is a UL-listed instrumentation cable featuring 16 pairs of 16 A...
- 9008 — The Belden 9008 is a single-conductor coaxial cable featuring a 13 AWG bare copp...
More Bulk Wire Cable
- 45094 — The Belden 45094 is an XTRAGUARD 4 cable with four 24 AWG (7x32) tinned copper c...
- 8762 — The Belden 8762 is a 2-conductor 20 AWG tinned copper cable with polyethylene in...
- 45166 — Belden part 45166 is an XTRAGUARD 4 cable with 6 conductors of 18 AWG (16x30) ti...
- 1333A — The Belden 1333A is a high-performance 24-pair 18AWG tinned copper fieldbus cabl...
- 76003WS — The Belden 76003WS is a highly flexible, 3-conductor 28 AWG tinned copper contro...
- 5033C — The Belden 5033C is an XTRAGUARD 1 cable with three 18 AWG tinned copper pairs,...
- 8469 — The Belden 8469 is a 9-conductor, 18 AWG tinned copper electronic cable with PVC...
- 25507D — The Belden 25507D is a Canadian Instrumentation Cable (TC-ACIC) rated 600 V, con...
1334A FAQ
What is 1334A?
1334A is a Bulk Wire Cable from Belden. The Belden 1334A is a 1-pair 18AWG tinned copper fieldbus cable with polypropylene insulation, overall Beldfoil and tinned copper braid shield, and an orange PVC outer jacket. It is designed for harsh environment digital and serial two-way communication, including oil and gas extraction, petrochemical plants, and Profibus or Foundation FieldBus process automation. The cable supports extreme temperature environments and long-distance remote location applications.
Who manufactures 1334A?
1334A is manufactured by Belden.
Where can I download the 1334A datasheet PDF?
The 1334A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1334A specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 60 lbs/1000ft |
| Installation Min. Bend Radius | 3.37 in (85.6 mm) |
| Max. Capacitance Unbalance | 1.2 pF/ft |
| Max. Current | 5.2 Amps per Conductor |
| Max. Pull Tension | 44.8 lbs (20.3 kg) |
| Nom. Capacitance Cond-to-Shield | 45 pF/ft (150 pF/m) |
| Nom. Characteristic Impedence | 100 Ohm |
| Nom. Conductor DCR | 7.2 Ohm/1000ft |
| Nom. Insertion Loss (Attenuation) | 0.069 dB/100ft |
| Nom Outer Shield DCR | 3.8 Ohm/1000ft (12 Ohm/km) |
| Nom. Velocity of Prop. | 66% |
| Operating Temperature | -40°C to +105°C |
| Stationary Min. Bend Radius | 3.37 in (85.6 mm) |
| UL Temperature | 90°C |
| UL Voltage Rating | 300 V RMS |