1293C Datasheet

BeldenBulk Wire Cable

The 1293C is a 3-conductor, 22 AWG tinned copper communication and control cable featuring semi-rigid PVC insulation, an overall aluminum/polyester shield, and an orange and black PVC outer jacket. It is rated for 300 V (CM, CMG) and 150 V (AWM 2576), with an operating temperature range of -20°C to +80°C. This cable is designed for use in industrial control systems, instrumentation, PLC and DCS systems, and analog/digital signal transmission.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

1293C Key Specifications

Nom. Capacitance Cond-to-Cond
35 pF/ft (110 pF/m)
Nom. Capacitance Cond-to-Other
63 pF/ft (210 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)
Voltage Rating
300 V (CM, CMG), 150 V (AWM 2576)
Operating Temperature
-20°C To +80°C (UL Temperature 80°C)
Conductor(s)
3, 22 AWG 7x30 TC - Tinned Copper
Max. Pull Tension / Min. Bend Radius (Stationary)
38 lbs (17 kg) / 1.8 in (46 mm)
Overall Cable Diameter (Nominal)
0.176 in (4.47 mm)

1293C Marking Code (SMD Code)

Top marking: Alpha Wire -* P/N 1293C 3C 22 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2576 --- LLXXXXXX CSA TYPE CMG FT4 CE ROHS

Characteristics (datasheet)

Conductor(s)
3, 22 AWG 7x30 TC - Tinned Copper
Voltage Rating
300 V (CM, CMG), 150 V (AWM 2576)
Operating Temperature
-20°C To +80°C (UL Temperature 80°C)
Overall Cable Diameter (Nominal)
0.176 in (4.47 mm)
Nom. Capacitance Cond-to-Cond
35 pF/ft (110 pF/m)
Nom. Capacitance Cond-to-Other
63 pF/ft (210 pF/m)
Nom. Inductance
0.18 µH/ft (0.59 µH/m)
Max. Pull Tension / Min. Bend Radius (Stationary)
38 lbs (17 kg) / 1.8 in (46 mm)

1293C Applications

  • Industrial control systems, raceways, cable trays, and ducts
  • Instrumentation and control circuits
  • Analog and digital signals (4–20 mA, 0–10 V)
  • PLC and DCS systems
  • Sensors, encoders, solenoids, valves, actuators, and positioners

Other Belden parts

  • 83712 — The Belden 83712 is a high-temperature 12-conductor 16 AWG tinned copper cable w...
  • 8110 — The Belden 8110 is a computer EIA RS-232/422 low-capacitance communication cable...
  • 1220B — The 1220B is an audio snake cable containing 12 individually shielded 22 AWG tin...
  • 21627 — The Belden 21627 is a CSA Tray Cable (TC-CIC) rated 600 V containing 29 conducto...
  • 77207 — The Belden 77207 is an ECOCABLE featuring 4 conductors of 20 AWG stranded tinned...
  • 1557 — The Belden 1557 is a single-conductor hook-up wire constructed of 16 AWG tinned...
  • 9179B — The Belden 9179B is a flexible RG 179 type coaxial cable featuring a single 30 A...
  • 58133 — The Belden 58133 is a plenum-rated communication and control cable featuring thr...

More Bulk Wire Cable

  • 55386 — The Belden 55386 is a high-performance 6-conductor, 18 AWG (7x26) tinned copper...
  • 65245CY — The Belden 65245CY is a 5-conductor, 24 AWG XTRAGUARD FLEX flexible control cabl...
  • 7810A — The Belden 7810A is a 50 Ohm wireless transmission coaxial cable (RG-8, 10 AWG)...
  • 5220C — The Belden 5220C is a multi-conductor shielded/unshielded control cable featurin...
  • 5129C — The Belden 5129C is a shielded, semi-rigid multi-pair cable consisting of 9 pair...
  • 23523D — The Belden 23523D is a Canadian instrumentation cable (TC-ACIC) rated 300 V, bui...
  • 9546 — The Belden 9546 is a computer EIA RS-232 cable consisting of 50 stranded tinned...
  • 9933 — The Belden 9933 is a computer EIA RS-232/423 cable featuring 24 AWG stranded tin...

1293C FAQ

What is 1293C?

1293C is a Bulk Wire Cable from Belden. The 1293C is a 3-conductor, 22 AWG tinned copper communication and control cable featuring semi-rigid PVC insulation, an overall aluminum/polyester shield, and an orange and black PVC outer jacket. It is rated for 300 V (CM, CMG) and 150 V (AWM 2576), with an operating temperature range of -20°C to +80°C. This cable is designed for use in industrial control systems, instrumentation, PLC and DCS systems, and analog/digital signal transmission.

Who manufactures 1293C?

1293C is manufactured by Belden.

What is the marking code of 1293C?

According to its datasheet, 1293C is marked "Alpha Wire -* P/N 1293C 3C 22 AWG SHIELDED 75C (UL) TYPE CM OR AWM 2576 --- LLXXXXXX CSA TYPE CMG FT4 CE ROHS".

Where can I download the 1293C datasheet PDF?

The 1293C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 1293C specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor(s)3, 22 AWG 7x30 TC - Tinned Copper
Max. Pull Tension / Min. Bend Radius (Stationary)38 lbs (17 kg) / 1.8 in (46 mm)
Nom. Capacitance Cond-to-Cond35 pF/ft (110 pF/m)
Nom. Capacitance Cond-to-Other63 pF/ft (210 pF/m)
Nom. Inductance0.18 µH/ft (0.59 µH/m)
Operating Temperature-20°C To +80°C (UL Temperature 80°C)
Overall Cable Diameter (Nominal)0.176 in (4.47 mm)
Voltage Rating300 V (CM, CMG), 150 V (AWM 2576)