1091A Datasheet
The Belden 1091A is a multi-conductor instrumentation cable featuring 20 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 300V (CMG, PLTC, UL AWM 2464) and 150V (ITC), and is designed for use in industrial control, digital control, instrumentation (4-20mA, 0-10V), DCS, and PLC systems. It operates within a temperature range of -30°C to +105°C and has a nominal outer diameter of 0.843 in (21.4 mm).
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
1091A Key Specifications
- Max. Current
- 3 Amps per conductor @ 25°C
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- UL Voltage Rating
- 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
- Operating Temperature
- -30°C to +105°C (UL Temperature 105°C)
- Conductor configuration
- 20 pairs of 20 AWG 7x28 bare copper and 1 comm wire of 22 AWG 7x30 bare copper
- Minimum bend radius (stationary and installation)
- 8.4 in (210 mm)
- Nom. Conductor DCR (Pairs / Comm Wire)
- 9.5 Ohm/1000ft (31 Ohm/km) / 14.7 Ohm/1000ft (48.2 Ohm/km)
- Nominal overall diameter
- 0.843 in (21.4 mm)
Characteristics (datasheet)
- Conductor configuration
- 20 pairs of 20 AWG 7x28 bare copper and 1 comm wire of 22 AWG 7x30 bare copper
- Nominal overall diameter
- 0.843 in (21.4 mm)
- UL Voltage Rating
- 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
- Max. Current
- 3 Amps per conductor @ 25°C
- Operating Temperature
- -30°C to +105°C (UL Temperature 105°C)
- Nom. Conductor DCR (Pairs / Comm Wire)
- 9.5 Ohm/1000ft (31 Ohm/km) / 14.7 Ohm/1000ft (48.2 Ohm/km)
- Nom. Capacitance Cond-to-Cond
- 30 pF/ft (98 pF/m)
- Minimum bend radius (stationary and installation)
- 8.4 in (210 mm)
1091A Applications
- Industrial control
- Raceways, cable trays and ducts
- Digital control
- Instruments (4-20mA, 0-10V)
- Low voltage digital control (24V)
- Encoders
- Control circuits
- Distributed control system (DCS)
- Programmable logic controller (PLC)
- Solenoids, valves, actuators, positioners
Other Belden parts
- 29732C — Belden 29732C is a 3-conductor 4/0 AWG bare copper VFD cable with XLPE insulatio...
- 7933A — The Belden 7933A is a DataTuff Category 5e industrial Ethernet cable featuring t...
- 8527 — The Belden 8527 is a low-temperature plastic lead wire featuring a 12 AWG tinned...
- 6654 — The Belden 6654 is a 4-conductor communication and control cable made of 18 AWG...
- 9613 — The Belden 9613 is an EIA RS-232 computer communication cable featuring eight 24...
- 7927A — The Belden 7927A is an Industrial Ethernet Category 6 cable featuring four bonde...
- 77803W — The Belden 77803W is a MachFlex™ high-flexibility cable designed with a 3+G cond...
- 6307 — The Belden 6307 is a multi-conductor communication and control cable with 15 con...
More Bulk Wire Cable
- 83712 — The Belden 83712 is a high-temperature 12-conductor 16 AWG tinned copper cable w...
- 2153PE — The Belden 2153PE is a discontinued commercial audio cable designed primarily fo...
- 9495 — The Belden 9495 is a high-performance instrumentation cable featuring a single t...
- 50091L — The Belden 50091L is a single-pair RS-485 cable with 22 AWG stranded tinned copp...
- 9165 — The Belden 9165 is a composite cable designed for ENG, EFP, and CCTV application...
- 24512D — The Belden 24512D is a Canadian instrumentation cable (TC-ACIC) rated 600 V, con...
- 34490 — Belden part 34490 is a 1/0 AWG tinned copper lead wire with chlorosulphonated po...
- 25122 — Belden part 25122 is an XTRAGUARD 2 cable consisting of 2 pairs of 22 AWG (7x30)...
1091A FAQ
What is 1091A?
1091A is a Bulk Wire Cable from Belden. The Belden 1091A is a multi-conductor instrumentation cable featuring 20 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 300V (CMG, PLTC, UL AWM 2464) and 150V (ITC), and is designed for use in industrial control, digital control, instrumentation (4-20mA, 0-10V), DCS, and PLC systems. It operates within a temperature range of -30°C to +105°C and has a nominal outer diameter of 0.843 in (21.4 mm).
Who manufactures 1091A?
1091A is manufactured by Belden.
Where can I download the 1091A datasheet PDF?
The 1091A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 1091A specifications
Click to ask a quick question:
Parameters
| Conductor configuration | 20 pairs of 20 AWG 7x28 bare copper and 1 comm wire of 22 AWG 7x30 bare copper |
| Max. Current | 3 Amps per conductor @ 25°C |
| Minimum bend radius (stationary and installation) | 8.4 in (210 mm) |
| Nom. Capacitance Cond-to-Cond | 30 pF/ft (98 pF/m) |
| Nom. Conductor DCR (Pairs / Comm Wire) | 9.5 Ohm/1000ft (31 Ohm/km) / 14.7 Ohm/1000ft (48.2 Ohm/km) |
| Nominal overall diameter | 0.843 in (21.4 mm) |
| Operating Temperature | -30°C to +105°C (UL Temperature 105°C) |
| UL Voltage Rating | 300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC) |