1091A Datasheet

BeldenBulk Wire Cable

The Belden 1091A is a multi-conductor instrumentation cable featuring 20 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 300V (CMG, PLTC, UL AWM 2464) and 150V (ITC), and is designed for use in industrial control, digital control, instrumentation (4-20mA, 0-10V), DCS, and PLC systems. It operates within a temperature range of -30°C to +105°C and has a nominal outer diameter of 0.843 in (21.4 mm).

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

1091A Key Specifications

Max. Current
3 Amps per conductor @ 25°C
Nom. Capacitance Cond-to-Cond
30 pF/ft (98 pF/m)
UL Voltage Rating
300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
Operating Temperature
-30°C to +105°C (UL Temperature 105°C)
Conductor configuration
20 pairs of 20 AWG 7x28 bare copper and 1 comm wire of 22 AWG 7x30 bare copper
Minimum bend radius (stationary and installation)
8.4 in (210 mm)
Nom. Conductor DCR (Pairs / Comm Wire)
9.5 Ohm/1000ft (31 Ohm/km) / 14.7 Ohm/1000ft (48.2 Ohm/km)
Nominal overall diameter
0.843 in (21.4 mm)

Characteristics (datasheet)

Conductor configuration
20 pairs of 20 AWG 7x28 bare copper and 1 comm wire of 22 AWG 7x30 bare copper
Nominal overall diameter
0.843 in (21.4 mm)
UL Voltage Rating
300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)
Max. Current
3 Amps per conductor @ 25°C
Operating Temperature
-30°C to +105°C (UL Temperature 105°C)
Nom. Conductor DCR (Pairs / Comm Wire)
9.5 Ohm/1000ft (31 Ohm/km) / 14.7 Ohm/1000ft (48.2 Ohm/km)
Nom. Capacitance Cond-to-Cond
30 pF/ft (98 pF/m)
Minimum bend radius (stationary and installation)
8.4 in (210 mm)

1091A Applications

  • Industrial control
  • Raceways, cable trays and ducts
  • Digital control
  • Instruments (4-20mA, 0-10V)
  • Low voltage digital control (24V)
  • Encoders
  • Control circuits
  • Distributed control system (DCS)
  • Programmable logic controller (PLC)
  • Solenoids, valves, actuators, positioners

Other Belden parts

  • 29732C — Belden 29732C is a 3-conductor 4/0 AWG bare copper VFD cable with XLPE insulatio...
  • 7933A — The Belden 7933A is a DataTuff Category 5e industrial Ethernet cable featuring t...
  • 8527 — The Belden 8527 is a low-temperature plastic lead wire featuring a 12 AWG tinned...
  • 6654 — The Belden 6654 is a 4-conductor communication and control cable made of 18 AWG...
  • 9613 — The Belden 9613 is an EIA RS-232 computer communication cable featuring eight 24...
  • 7927A — The Belden 7927A is an Industrial Ethernet Category 6 cable featuring four bonde...
  • 77803W — The Belden 77803W is a MachFlex™ high-flexibility cable designed with a 3+G cond...
  • 6307 — The Belden 6307 is a multi-conductor communication and control cable with 15 con...

More Bulk Wire Cable

  • 83712 — The Belden 83712 is a high-temperature 12-conductor 16 AWG tinned copper cable w...
  • 2153PE — The Belden 2153PE is a discontinued commercial audio cable designed primarily fo...
  • 9495 — The Belden 9495 is a high-performance instrumentation cable featuring a single t...
  • 50091L — The Belden 50091L is a single-pair RS-485 cable with 22 AWG stranded tinned copp...
  • 9165 — The Belden 9165 is a composite cable designed for ENG, EFP, and CCTV application...
  • 24512D — The Belden 24512D is a Canadian instrumentation cable (TC-ACIC) rated 600 V, con...
  • 34490 — Belden part 34490 is a 1/0 AWG tinned copper lead wire with chlorosulphonated po...
  • 25122 — Belden part 25122 is an XTRAGUARD 2 cable consisting of 2 pairs of 22 AWG (7x30)...

1091A FAQ

What is 1091A?

1091A is a Bulk Wire Cable from Belden. The Belden 1091A is a multi-conductor instrumentation cable featuring 20 pairs of 20 AWG and one 22 AWG bare copper conductors with PVC insulation, individual and overall Beldfoil shields, and a black PVC outer jacket. It is rated for 300V (CMG, PLTC, UL AWM 2464) and 150V (ITC), and is designed for use in industrial control, digital control, instrumentation (4-20mA, 0-10V), DCS, and PLC systems. It operates within a temperature range of -30°C to +105°C and has a nominal outer diameter of 0.843 in (21.4 mm).

Who manufactures 1091A?

1091A is manufactured by Belden.

Where can I download the 1091A datasheet PDF?

The 1091A datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 1091A specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor configuration20 pairs of 20 AWG 7x28 bare copper and 1 comm wire of 22 AWG 7x30 bare copper
Max. Current3 Amps per conductor @ 25°C
Minimum bend radius (stationary and installation)8.4 in (210 mm)
Nom. Capacitance Cond-to-Cond30 pF/ft (98 pF/m)
Nom. Conductor DCR (Pairs / Comm Wire)9.5 Ohm/1000ft (31 Ohm/km) / 14.7 Ohm/1000ft (48.2 Ohm/km)
Nominal overall diameter0.843 in (21.4 mm)
Operating Temperature-30°C to +105°C (UL Temperature 105°C)
UL Voltage Rating300 V (CMG, PLTC, UL AWM 2464), 150 V (ITC)