6307 Datasheet
The Belden 6307 is a multi-conductor communication and control cable with 15 conductors of 24 AWG tinned copper, semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, suitable for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for a UL voltage of 300 V and supports an operating temperature range of -20°C to +80°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6307 Key Specifications
- Nom. Capacitance Cond-to-Cond
- 31 pF/ft (100 pF/m)
- Nom. Capacitance Cond-to-Other (Conds + Shield)
- 56 pF/ft (180 pF/m)
- Nom. Inductance
- 0.19 µH/ft (0.62 µH/m)
- UL Voltage Rating
- 300 V (CMG, CM, AWM 2464)
- Temperature
- UL Temperature 80°C, Operating -20°C To +80°C
- Conductor count and size
- 15 Conductor 24 AWG 7x32 TC - Tinned Copper
- Max. Pull Tension
- 208 lbs (94.3 kg)
- Nominal overall cable diameter
- 0.270 in (6.86 mm)
Characteristics (datasheet)
- Conductor count and size
- 15 Conductor 24 AWG 7x32 TC - Tinned Copper
- Nominal overall cable diameter
- 0.270 in (6.86 mm)
- UL Voltage Rating
- 300 V (CMG, CM, AWM 2464)
- Temperature
- UL Temperature 80°C, Operating -20°C To +80°C
- Nom. Capacitance Cond-to-Cond
- 31 pF/ft (100 pF/m)
- Nom. Capacitance Cond-to-Other (Conds + Shield)
- 56 pF/ft (180 pF/m)
- Nom. Inductance
- 0.19 µH/ft (0.62 µH/m)
- Nom Outer Shield DCR
- 159 Ohm/1000ft (522 Ohm/km)
- Stationary Min. Bend Radius
- 2.7 in (69 mm)
- Max. Pull Tension
- 208 lbs (94.3 kg)
6307 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 3090A — The Belden 3090A is a UL-listed instrumentation cable featuring a single pair of...
- 86501CY — The Belden 86501CY is a continuous flex XTRAGUARD data cable with a single pair...
- 3613 — The Belden 3613 is a Category 6+ premium premise horizontal cable (400 MHz) with...
- 5564C — The Belden 5564C is a 19-conductor, 20 AWG tinned copper multi-conductor cable f...
- 9979 — The part 9979 is a low-temp plastic lead wire featuring a 22 AWG solid tinned co...
- 8054 — The 8054 is a 28 AWG solid bare copper magnet wire with PUR/NYL insulation, desi...
- 78353 — The 78353 is a shielded, 3-pair 28 AWG tinned copper cable with modified polyphe...
- 76103WS — The Belden 76103WS is a MachFlex™ high-flex, 3-conductor 26 AWG tinned copper ca...
More Bulk Wire Cable
- 88723 — The Belden 88723 is an audio, control, and instrument cable featuring two indivi...
- 78046 — The Belden 78046 is a 6-conductor, 20 AWG stranded tinned copper cable with modi...
- 9680 — The Belden 9680 is a 3-pair, 24 AWG stranded tinned copper conductor communicati...
- 80001 — The Belden 80001 ECOFLEX PUR is a 2-conductor, 28 AWG tinned copper cable with M...
- 1590 — The Belden 1590 is a heavy-duty TW-75 600V bulk cable featuring a single 1 AWG 1...
- 8631MN — The Belden 8631MN is a SpaceMaker™ multi-conductor cable designed for indoor use...
- 5474C — The Belden 5474C is a shielded, 4-pair 24 AWG tinned copper communication and co...
- 30830 — Belden 30830 is a 3/0 AWG (630x26) tinned copper lead wire with silicone rubber...
6307 FAQ
What is 6307?
6307 is a Bulk Wire Cable from Belden. The Belden 6307 is a multi-conductor communication and control cable with 15 conductors of 24 AWG tinned copper, semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, suitable for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for a UL voltage of 300 V and supports an operating temperature range of -20°C to +80°C.
Who manufactures 6307?
6307 is manufactured by Belden.
Where can I download the 6307 datasheet PDF?
The 6307 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6307 specifications
Click to ask a quick question:
Parameters
| Conductor count and size | 15 Conductor 24 AWG 7x32 TC - Tinned Copper |
| Max. Pull Tension | 208 lbs (94.3 kg) |
| Nom. Capacitance Cond-to-Cond | 31 pF/ft (100 pF/m) |
| Nom. Capacitance Cond-to-Other (Conds + Shield) | 56 pF/ft (180 pF/m) |
| Nominal overall cable diameter | 0.270 in (6.86 mm) |
| Nom. Inductance | 0.19 µH/ft (0.62 µH/m) |
| Nom Outer Shield DCR | 159 Ohm/1000ft (522 Ohm/km) |
| Stationary Min. Bend Radius | 2.7 in (69 mm) |
| Temperature | UL Temperature 80°C, Operating -20°C To +80°C |
| UL Voltage Rating | 300 V (CMG, CM, AWM 2464) |