Wire Cable Assemblies

21679

Belden 21679 is a CSA TC-CIC 600 V tray cable with four 4/0 AWG bare copper conductors and one 4 AWG bare copper ground conductor. It uses XLPE/XLPO/XLP thermoset insulation, a black PVC jacket with ripcord, and is rated 90 °C dry/wet for direct burial, indoor, and outdoor use. It is suitable for CEC power and control applications.{

Belden
11 3

22633D

Belden 22633D is a Canadian Instrumentation Cable (TC-CIC) rated 300 V with two pairs of 18 AWG tinned copper conductors, XLPE insulation, individual and overall Beldfoil shields, and a black PVC jacket. It is rated for indoor and outdoor use with sunlight and UV resistance, and operates from -25 °C to +105 °C. The cable has a nominal overall diameter of 0.463 in and includes a ripcord.

Belden
11 3

22635

Belden 22635 is a Canadian Instrumentation Cable (TC-CIC) rated at 300 V, built with 8 pairs of 18 AWG (7x26) stranded tinned copper conductors. It features PVC insulation, individual and overall Beldfoil® shields at 100% coverage, and a black PVC jacket suitable for indoor and outdoor use from -40 °C to +105 °C.

Belden
11 3

22637D

Belden 22637D is a Canadian Instrumentation Cable (TC-CIC) rated 300 V, with 24 pairs of 18 AWG stranded copper conductors, XLPE insulation, individual and overall Beldfoil® shielding, and a black PVC jacket with ripcord. It is rated 90 °C dry/wet, sunlight resistant, and suitable down to -25 °C. The cable complies with FT4, CIC/CSA C22.2 No. 239, and China RoHS II.

Belden
11 3

23501D

The Belden 23501D is a Canadian TC-ACIC instrumentation cable rated at 300 V, built with one 16 AWG (7x24) tinned copper pair, XLPE insulation, an overall Beldfoil shield, PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is intended for indoor and outdoor industrial applications such as instrument signals, digital control, encoders, DCS/PLC systems, solenoids, valves, actuators, and positioners.

Belden
11 3

23525D

The Belden 23525D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V with 12 pairs of 16 AWG (7x24) tinned copper conductors, XLPE insulation, individual and overall Beldfoil® shield, PVC inner jacket, aluminum interlock armor, and PVC outer jacket. It is intended for industrial control, raceways/cable trays/ducts, digital control, instruments (4-20 mA, 0-10 V), low voltage digital control (24 V), encoders, control circuits, DCS/PLC systems, solenoids, valves, actuators, and positioners. The cable operates from -40 °C to +105 °C dry / 90 °C wet and is sunlight resistant.

Belden
11 3

23528D

The Belden 23528D is a Canadian TC-ACIC instrumentation cable rated 300 V with six 18 AWG (7x26) tinned copper pairs. It uses XLPE insulation, individual and overall Beldfoil shields, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket, rated for -40 °C to +90 °C wet / 105 °C dry operation. It is intended for industrial control, raceways/cable trays, digital control, instruments (4-20 mA, 0-10 V), encoders, control circuits, DCS/PLC systems, solenoids, valves, actuators, and positioners.

Belden
11 3

23532D

Belden part 23532D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V with 16 pairs (32 conductors) of 20 AWG, 7x28 stranded tinned copper and XLPE insulation. It uses individual and overall 100% Beldfoil shields, a black PVC inner jacket, aluminum interlock armor, and a PVC outer jacket, and is sunlight resistant with a -40 °C rating. It is intended for industrial control, raceways/cable trays/ducts, digital control, instruments (4-20 mA, 0-10 V), low-voltage digital control (24 V), encoders, control circuits, DCS, PLC, solenoids, valves, actuators, and positioners.

Belden
11 3

23538D

Belden 23538D is a Canadian instrumentation cable (TC-ACIC) with 24 pairs of 16 AWG (7x24) tinned copper conductors, XLPE insulation, individual and overall Beldfoil® shielding, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated 300 V for operation at -40°C to +90°C wet / +105°C dry and is intended for industrial control, cable trays, digital control, instruments, DCS, PLCs, solenoids, valves, actuators, and positioners.

Belden
11 3

24506D

Belden 24506D is a Canadian TC-ACIC 600 V instrumentation cable built with six 16 AWG (7x24) tinned copper pairs, XLPE insulation with E1 color code, individual and overall Beldfoil® shielding, a black PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated for 90 °C wet and 105 °C dry operation with -40 °C cold suitability, sunlight/UV resistance, and CSA HLABCD compliance. It is intended for industrial control, instrumentation, and process wiring in raceways, cable trays, and ducts.

Belden
11 3

24511

Belden part 24511 is an ACIC 600 V instrumentation cable: one 18 AWG (7x26) tinned copper pair with PVC insulation (black & white), an overall Beldfoil shield with a 20 AWG tinned copper drainwire, a PVC inner jacket, aluminum interlock armor, and a PVC outer jacket. It is rated 105 °C dry / 75 °C wet, −40 °C, sunlight resistant, and is suited for industrial control, raceways, cable trays and ducts, digital control, instruments (4-20 mA, 0-10 V), low-voltage digital control (24 V), encoders, control circuits, DCS, PLC, solenoids, valves, actuators and positioners.

Belden
11 3

25002

The Belden 25002 is an XTRAGUARD 2 two-conductor cable using 22 AWG (7x30) tinned copper conductors with semi-rigid PVC insulation and a slate polyurethane outer jacket. It is rated for 300 V and is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable has a nominal overall diameter of 0.168 in (4.27 mm) and includes a ripcord.\n","key_specs":["2 conductors, 22 AWG (7x30) tinned copper","SR-PVC semi-rigid insulation, 0.010 in (0.25 mm) nominal thickness","PUR polyurethane outer jacket, 0.168 in (4.27 mm) nominal diameter, ripcord yes","Capacitance cond-to-cond: 22.8 pF/ft (74.8 pF/m)","Characteristic impedance: 80 Ohm","Voltage rating: 300 V (AWM 20668) / 300 V (CSA AWM)","Operating temperature: -30°C to +90°C (UL 105°C)","Max pull tension: 52 lbs (24 kg); stationary bend radius min 1.7 in (43 mm)"],"absolute_max_ratings":[],"pin_table":[],"marking_code":null,"applications":["Data transmission","Communication","Audio","Low-level signal transmission","Industrial networking","Serial communication","Control panels","Automation equipment","Instrumentation systems"]}```

Belden
11 3

25013

Belden part 25013 (XTRAGUARD 2) is a 3-conductor, 24 AWG (7x32 stranded tinned copper) cable with semi-rigid PVC insulation and a slate polyurethane (TPU) outer jacket. It is rated 300 V under AWM/Style 20668 and CSA AWM, with a UL temperature rating of 105 °C and an operating range of -30 °C to +90 °C. It is intended for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
11 3

25058

Belden 25058 is an 8-conductor 20 AWG (7/28) tinned copper cable with PVC insulation and a slate polyurethane (TPU) outer jacket. It is rated 300 V (AWM 20668 / CSA AWM), VW-1 and FT1 flame rated, with UL temperature 105°C and operating range -30°C to +90°C. It is intended for data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
11 3

25103

Belden 25103 is an XTRAGUARD 2 cable with 3 conductors of 22 AWG (7/30) tinned copper, semi-rigid PVC insulation, an overall aluminum/polyester shield with a tinned copper braid, and a slate polyurethane outer jacket. It is rated 300 V and is designed for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
11 3

25118

Belden 25118 is an XTRAGUARD 2 cable with eight 24 AWG (7x32) tinned copper conductors, semi-rigid PVC insulation, an overall aluminum/polyester shield plus tinned copper braid, and a slate polyurethane jacket. It is rated 300 V under AWM 20668 and CSA AWM, with an operating temperature range of -30°C to +90°C. It is intended for data, communication, audio, low-level signal, industrial networking, serial communication, control panel, automation equipment, and instrumentation applications.}

Belden
11 3

25129

Belden part 25129 is an XTRAGUARD 2 cable with nine 22 AWG (7/30) tinned copper pairs, semi-rigid PVC insulation, an overall aluminum/polyester foil shield plus 70% tinned copper braid, and a slate polyurethane jacket. It is rated 300 V (AWM 20668 / CSA AWM) and is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.

Belden
11 3

25136

Belden part 25136 is an XTRAGUARD 2 cable built with six 18 AWG (16x30) tinned copper pairs, PVC insulation, an aluminum/polyester tape shield at 100% coverage plus a 70% tinned copper braid, and a slate polyurethane outer jacket. It is rated 300 V and is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable has a nominal overall diameter of 0.488 in (12.4 mm), an operating temperature range of -30°C to +90°C, and a stationary minimum bend radius of 4.9 in (120 mm).

Belden
11 3

21648

The Belden 21648 is a CSA Type TC-CIC tray cable containing 50 conductors of 10 AWG bare copper (7x18 stranded) plus one 12 AWG bare copper ground conductor. It has XLPE insulation, a black PVC outer jacket with ripcord, no shield, and is rated 600 V for CEC power and control applications. It is suitable for direct burial, indoor/outdoor use, and sunlight/UV resistance.

Belden
11 2

21667

The Belden 21667 is a CSA Type TC tray cable rated 600 V, containing four 1 AWG bare copper power conductors (19x14 stranding) and one 6 AWG bare copper ground conductor (7x14), with XLPE/XLPO/XLP thermoset insulation and a black PVC outer jacket. It is rated 90 °C dry and wet (operating -40 °C to 90 °C), is sunlight resistant and suitable for direct burial, and is intended for CEC power and control applications. The cable has a nominal overall diameter of 1.346 in (34.19 mm) and includes a ripcord.

Belden
11 2