21648 Datasheet

BeldenBulk Wire Cable

The Belden 21648 is a CSA Type TC-CIC tray cable containing 50 conductors of 10 AWG bare copper (7x18 stranded) plus one 12 AWG bare copper ground conductor. It has XLPE insulation, a black PVC outer jacket with ripcord, no shield, and is rated 600 V for CEC power and control applications. It is suitable for direct burial, indoor/outdoor use, and sunlight/UV resistance.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

21648 Key Specifications

Max. current
35 Amps per Conductor at 30ºC
Voltage rating
600 V (CSA TC)
Installation temperature
-25°C To +90
Operating temperature
-40°C To +90°C
Bulk cable weight
2393 lbs/1000ft (3561 kg/km)
Conductor(s)
50 x 10 AWG, 7x18 stranding, bare copper
Ground conductor
1 x 12 AWG, 7x18 stranding, bare copper
Nominal conductor DCR
1.04 Ohm/1000ft (3.41 Ohm/km)

Characteristics (datasheet)

Conductor(s)
50 x 10 AWG, 7x18 stranding, bare copper
Ground conductor
1 x 12 AWG, 7x18 stranding, bare copper
Voltage rating
600 V (CSA TC)
Max. current
35 Amps per Conductor at 30ºC
Nominal conductor DCR
1.04 Ohm/1000ft (3.41 Ohm/km)
Operating temperature
-40°C To +90°C
Installation temperature
-25°C To +90
Overall cable diameter (nominal)
1.653 in (41.99 mm)
Bulk cable weight
2393 lbs/1000ft (3561 kg/km)

21648 Applications

  • CEC Power and Control Applications

Other Belden parts

  • 6020C — The Belden 6020C is a shielded multi-conductor communication and control cable f...
  • 86205 — The Belden 86205 is a 5-conductor, 24 AWG tinned copper cable with semi-rigid PV...
  • 80021 — The Belden 80021 (ECOFLEX PUR) is a 3-conductor, 20 AWG tinned copper cable with...
  • 78393 — The part 78393 is an ECOCABLE featuring three pairs of 20 AWG stranded tinned co...
  • 2411C — The Belden 2411C is a 2-conductor, 20 AWG tinned copper communication and contro...
  • 6212C — The Belden 6212C is a shielded communication and control cable featuring 2 pairs...
  • 9306 — The Belden 9306 is an audio, control, and instrument cable consisting of six twi...
  • 2816RW — The Belden 2816RW is an indoor/outdoor stadium cable designed as an analog audio...

More Bulk Wire Cable

  • 8107 — The Belden 8107 is a computer EIA RS-232/422 low-capacitance cable featuring 7 t...
  • 87404CY — The 87404CY is a flexible 4-conductor, 16 AWG shielded cable designed for data,...
  • 5672 — The Belden 5672 is an XTRAGUARD 1 multi-conductor cable featuring 10 conductors...
  • 8910 — The Belden 8910 is a low-temperature plastic lead wire featuring a 10 AWG tinned...
  • 80033 — The Belden 80033 is a 3-conductor, 18 AWG tinned copper control cable with mPPE...
  • 8669 — The Belden 8669 is a tinned copper (TC) braid conductor of 8.9 AWG (336x34) desi...
  • 5942 — The Belden 5942 is a 6-pair, 28 AWG tinned copper conductor cable with semi-rigi...
  • 1346F — The 1346F is a DeviceBus® cable designed for ODVA DeviceNet™ applications, featu...

21648 FAQ

What is 21648?

21648 is a Bulk Wire Cable from Belden. The Belden 21648 is a CSA Type TC-CIC tray cable containing 50 conductors of 10 AWG bare copper (7x18 stranded) plus one 12 AWG bare copper ground conductor. It has XLPE insulation, a black PVC outer jacket with ripcord, no shield, and is rated 600 V for CEC power and control applications. It is suitable for direct burial, indoor/outdoor use, and sunlight/UV resistance.

Who manufactures 21648?

21648 is manufactured by Belden.

Where can I download the 21648 datasheet PDF?

The 21648 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 21648 specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk cable weight2393 lbs/1000ft (3561 kg/km)
Conductor(s)50 x 10 AWG, 7x18 stranding, bare copper
Ground conductor1 x 12 AWG, 7x18 stranding, bare copper
Installation temperature-25°C To +90
Max. current35 Amps per Conductor at 30ºC
Nominal conductor DCR1.04 Ohm/1000ft (3.41 Ohm/km)
Operating temperature-40°C To +90°C
Overall cable diameter (nominal)1.653 in (41.99 mm)
Voltage rating600 V (CSA TC)