Wire Cable Assemblies
25113
Belden part 25113 is an XTRAGUARD 2 cable with three 24 AWG (7/32) tinned copper conductors, semi-rigid PVC insulation, an aluminum/polyester plus tinned copper braid shield, and a slate polyurethane outer jacket. It is rated 300 V and is used for data, communication, audio, and low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25192
Belden part 25192 (XTRAGUARD 2) is a 2-conductor cable built with 22 AWG (7x30) tinned copper conductors, semi-rigid PVC insulation, an overall aluminum/polyester bi-laminate shield with 100% coverage and a 22 AWG drainwire, and a slate polyurethane outer jacket with ripcord. It is rated 300 V (UL AWM 20668 / CSA AWM), 105°C UL with an operating range of -30°C to +90°C, and is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25194
Belden 25194 is an XTRAGUARD 2 cable with 4 conductors of 22 AWG (7/30) tinned copper, semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate polyurethane outer jacket. It is rated at 300 V and is intended for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable complies with UL/CSA AWM styles, VW-1/FT1 flammability ratings, and RoHS/UKCA/China RoHS directives.
25272
Belden 25272 is an XTRAGUARD 2 cable with 2 pairs of 24 AWG (7x32) stranded tinned copper conductors, semi-rigid PVC insulation, an overall aluminum/polyester foil shield plus 70% tinned copper braid, and a slate polyurethane outer jacket. It is rated 300 V and is intended for data, communication, audio, and low-level signal transmission such as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable has a nominal overall diameter of 0.240 in (6.10 mm), operates from -30°C to +90°C (UL 105°C), and complies with AWM 20668, VW-1, FT1, RoHS, and UKCA.}
25373
Belden 25373 is an XTRAGUARD 2 cable with 3 shielded pairs of 18 AWG (16x30) tinned copper conductors, PVC insulation, an overall aluminum/polyester bi-laminate shield with 100% coverage and an 18 AWG drainwire, and a slate polyurethane outer jacket with ripcord. It is rated for 300 V (AWM 20668 / CSA AWM), operates from -30°C to +90°C (UL 105°C), and is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25491
Belden 25491 is an XTRAGUARD 2 single-pair cable with 24 AWG (7x32) tinned copper conductors, semi-rigid PVC insulation, and an overall 100%-coverage aluminum/polyester bi-laminate shield with a 24 AWG drainwire, finished with a slate polyurethane jacket and ripcord. It is rated 300 V (UL AWM) / 600 V (CSA AWM TEW) and operates from -30 °C to +90 °C. It is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
25509D
The Belden 25509D is a Canadian instrumentation cable (TC-ACIC) rated 600 V, built with four triads of 16 AWG (7x24) stranded tinned copper conductors and XLPE insulation. It has an overall Beldfoil shield, PVC inner jacket, steel interlock armor, and a black PVC outer jacket, rated for -40 °C to 105 °C dry / 90 °C wet service. It is intended for industrial control, DCS/PLC systems, instruments, and related low-voltage control applications.
25543
The Belden 25543 is an XTRAGUARD 2 cable with three 14 AWG (41x30) tinned copper conductors, PVC insulation, and an overall shield consisting of 100% aluminum/polyester plus 70% tinned copper braid, under a slate polyurethane jacket with ripcord. It is rated 600 V for AWM 20669 and CSA/TEW use and is intended for data, communication, audio, low-level signal, industrial networking, serial communication, control panel, automation, and instrumentation systems. It operates from -30°C to +90°C (UL temperature 105°C).
27643A
Belden 27643A is a UL Type TC power and control cable with two 10 AWG bare copper conductors (7x18 stranding), PVC-nylon insulation, and a black PVC outer jacket. It is rated 600 V, 90 °C dry and wet, sunlight resistant, and suitable for direct burial and Class 1 Division 2 hazardous locations. Recommended applications are power and control circuits up to 600 V. The cable has no shield and includes a ripcord in the jacket.
28123A
The Belden 28123A is a 16-conductor, 12 AWG (7x20) bare copper power and control cable with PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF) at 90°C dry/wet and is suitable for indoor, outdoor, sunlight-resistant, UV-resistant, and direct-burial installations, including Class 1 Division 2 hazardous locations. The unshielded cable includes a ripcord and has a nominal overall diameter of 0.737 in.
28127A
The Belden 28127A is a UL Type TC-ER power and control cable with 20 conductors of 12 AWG (7x20) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated for 600 V (TC-ER) and 150 V (NPLF), with 90 °C dry/wet temperature rating and sunlight resistance for indoor, outdoor, wet/dry, and direct burial use. Suitable applications include power and control applications up to 600 V and Class 1 Division 2 hazardous locations.
28141A
The Belden 28141A is a UL Type TC power and control cable with five 10 AWG bare copper conductors (7x18 stranding) insulated with PVC/nylon and a black PVC outer jacket. It is rated 600 V and 90 °C dry/wet, and is suitable for indoor, outdoor, sunlight-resistant, direct-burial use and Class 1 Division 2 hazardous locations. The cable includes a ripcord and has a nominal overall diameter of 0.569 in (14.5 mm).
28154A
The Belden 28154A is a UL Type TC (1277) power and control cable with four 6 AWG bare copper conductors and one 8 AWG bare copper ground wire, using PVC/nylon insulation and a black PVC outer jacket. It is rated 600 V and 90 °C dry/wet, with an operating range of -30 °C to 90 °C wet/dry, and is suitable for indoor, outdoor, sunlight-resistant, UV-resistant, direct burial, and Class 1 Division 2 hazardous location applications.
28330A
Belden 28330A is a UL Type TC (1277) power and control cable with 16 conductors of 16 AWG (7x24) bare copper, PVC/nylon insulation, and a black PVC outer jacket. It is rated 600 V (TC-ER) and 150 V (NPLF), 90 °C dry/wet, sunlight resistant and suitable for direct burial. It is intended for power and control applications up to 600 V, including Class 1 Division 2 hazardous locations.
29557C
The Belden 29557C is a CSA-rated VFD power cable containing three 1 AWG bare copper conductors and three 10 AWG segmented bare copper grounds. It uses XLPE insulation, dual helically applied bare copper tape shields, and a black PVC jacket with a ripcord, rated for 1000 V. It is intended for variable frequency drives, AC motor and drive systems, and Canadian applications.
29723C
The Belden 29723C is a 3-conductor VFD power cable built with 10 AWG (7x18) bare copper conductors, XLPE insulation, and a symmetrical segmented ground (3 of 14 AWG bare copper). It includes an overall dual helical bare copper tape shield (100% coverage) and a black PVC outer jacket, rated at 2000 V (TC) / 1000 V (CSA AWM I/II A/B) with 90°C dry/wet temperature performance. It is intended for variable frequency drives, AC motor and drive systems, and high voltage requirements.
29728C
The Belden 29728C is a Basics VFD power cable built for variable frequency drives, AC motor and drive systems, and high voltage requirements. It contains three 1 AWG (19x14) bare copper conductors with XLPE insulation, plus three 10 AWG segmented bare copper grounds, all covered by dual 100% helical bare copper tape shields and a black PVC jacket. The cable is rated 2000 V (TC) and 1000 V (CSA AWM I/II A/B), with 90 °C dry/wet UL temperature rating and an operating range of -40 °C to +90 °C.
30802
Belden 30802 is a 2 AWG rubber lead wire with 163x24 stranded tinned copper conductor, silicone rubber insulation, and a lacquered glass braid outer jacket. It is rated 600 V under AWM 3125 and CSA SEW-2, with an operating temperature of -70°C to +200°C. Suitable applications include Class 130(B), 155(F) or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications.\n\n"}]}\n{"part": "30802", "summary": "Belden 30802 is a 2 AWG rubber lead wire with 163x24 stranded tinned copper conductor, silicone rubber insulation, and a lacquered glass braid outer jacket. It is rated 600 V under AWM 3125 and CSA SEW-2, with an operating temperature of -70°C to +200°C. Suitable applications include Class 130(B), 155(F) or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications.", "key_specs": [{"parameter": "Conductor", "value": "2 AWG, 163x24 stranding, tinned copper (TC)"}, {"parameter": "Insulation", "value": "Silicone rubber, 0.069 in (1.8 mm) nominal thickness"}, {"parameter": "Outer jacket", "value": "Lacquered glass braid covering, 0.496 in (12.6 mm) nominal diameter"}, {"parameter": "Overall cable diameter (nominal)", "value": "0.496 in (12.6 mm)"}, {"parameter": "Nominal conductor DCR", "value": "0.180 Ohm/1000ft"}, {"parameter": "Max. current", "value": "273.6 Amps per conductor at 30ºC"}, {"parameter": "Voltage rating", "value": "600 V (AWM 3125); 600 V (CSA SEW-2)"}, {"parameter": "Operating temperature", "value": "-70°C to +200°C (UL temperature 200°C)"}], "absolute_max_ratings": [], "pin_table": [], "marking_code": null, "applications": ["Class 130(B), 155(F) or 180(H) insulation systems", "internal wiring of lighting fixtures and appliances", "high temperature applications"]}
30816
Belden part 30816 is a 16 AWG (26x30) stranded tinned copper lead wire with silicone rubber insulation and a lacquered glass braid outer jacket. It is rated 600 V RMS, UL 150°C, with an operating temperature range of -70°C to +150°C, and complies with AWM 3070 and CSA SEWF-2. It is intended for Class 130(B), 155(F), or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications.{
30840
The Belden 30840 is a 4/0 AWG (266x21) tinned copper lead wire with silicone rubber insulation and a lacquered glass braid outer jacket. It is rated for 600 V RMS and 200 °C UL temperature with an operating range of -70 °C to +200 °C, and complies with AWM 3126 and CSA SEW-2. It is intended for Class 130(B), 155(F), or 180(H) insulation systems, internal wiring of lighting fixtures and appliances, and high temperature applications.