Wire Cable Assemblies
4502FE
The Belden 4502FE is a security and commercial audio cable featuring four 22 AWG stranded bare copper conductors with polypropylene insulation, a Beldfoil® shield, and a low smoke zero halogen (LSZH) jacket with a ripcord. It is designed for use in security systems, intercom/PA systems, audio/speaker applications, and power-limited controls in noisy environments, complying with CPR Euroclass Eca.
4509FE
The Belden 4509FE is a security and commercial audio cable consisting of 12 stranded bare copper conductors with polypropylene insulation, a Beldfoil shield, and a low smoke zero halogen (LSZH) outer jacket with a ripcord. It is designed for use in intercom/PA systems, sound/audio systems, and control systems. The cable is rated for a voltage of 300 V, a maximum recommended current of 2A, and an operating temperature range of -20°C to +70°C.
5026C
The Belden 5026C (branded as Alpha Wire) is a multi-conductor instrumentation cable consisting of six twisted pairs of 22 AWG tinned copper wires with semi-rigid PVC insulation and a slate-colored PVC outer jacket. It is rated for a maximum voltage of 300 V and operates safely within a temperature range of -35°C to +105°C. This cable is designed for industrial control, analog/digital signal transmission, and PLC/DCS applications, offering excellent resistance to sunlight, oil, and flame (UL FT4, CSA FT4, VW-1).
5036C
The Belden 5036C is an XTRAGUARD 1 multi-conductor cable featuring 6 pairs of 18 AWG stranded tinned copper conductors with PVC insulation and a slate PVC outer jacket. It is rated for a voltage of 300 V and operates within a temperature range of -30°C to +105°C, offering sunlight and oil resistance for indoor and outdoor environments. This cable is designed for industrial control, instrumentation, and PLC/DCS systems to transmit analog and digital signals to sensors, solenoids, valves, and positioners.
5039C
The Belden 5039C is an XTRAGUARD 1 multi-conductor cable with 9 pairs of 18 AWG tinned copper conductors, PVC insulation, and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -30°C to +105°C. This cable is designed for industrial control systems, raceways, cable trays, ducts, and instrumentation/control circuits, supporting analog and digital signals, PLCs, and sensors.
5052C
The Belden 5052C is a 2-conductor, 20 AWG tinned copper control cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and a temperature range of -30°C to +105°C. It is designed for industrial control systems, instrumentation, and control circuits, supporting analog and digital signals for sensors, solenoids, valves, and actuators. The cable offers sunlight and oil resistance, along with compliance to various flammability standards including VW-1, FT4, and IEC 60332-1-2 / IEC 60332-2-2.
5108C
The Belden 5108C is an XTRAGUARD 1 multi-conductor shielded cable featuring eight 22 AWG tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for a voltage of 300 V and supports operating temperatures between -35°C and +105°C. This cable is designed for use in industrial control systems, instrumentation and control circuits, analog and digital signal transmission, and PLC/DCS systems.
5114C
The Belden 5114C is a 4-conductor, 24 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for a voltage of 300 V and supports an operating temperature range of -35°C to +105°C. This cable is designed for industrial control systems, instrumentation, and PLC/DCS systems, carrying analog and digital signals in raceways, cable trays, and ducts.
5154C
The Belden 5154C is a shielded, 4-conductor 20 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures from -30°C to +105°C. It is designed for use in industrial control systems, instrumentation and control circuits, and PLC and DCS systems, supporting analog and digital signals. The cable features an overall aluminum/polyester shield and tinned copper braid to protect signal integrity in noisy environments.
5158C
The Belden 5158C is an XTRAGUARD 1 shielded multi-conductor cable featuring 8 conductors of 20 AWG tinned copper with PVC insulation and a slate PVC outer jacket. It is designed for industrial control systems, raceways, cable trays, ducts, and instrumentation/control circuits, supporting analog and digital signals for PLC and DCS systems. The cable is rated for an operating temperature of -30°C to +105°C and a voltage of 300 V, offering robust shielding and environmental resistance for demanding industrial applications.
5162C
The Belden 5162C is a 2-conductor, 18 AWG tinned copper cable with PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket (XTRAGUARD 1). It is rated for 300 V and an operating temperature range of -30°C to +105°C, designed for use in industrial control systems, instrumentation, and analog or digital signal transmission.
5198C
The 5198C is an 8-conductor, 22 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and operates within a temperature range of -35°C to +105°C. It is designed for industrial control systems, instrumentation and control circuits, PLC and DCS systems, and sensor/encoder applications, supporting both analog and digital signals.
5263C
The Belden 5263C is a multi-conductor signal cable featuring three 24 AWG tinned copper pairs with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for a maximum voltage of 300 V and operates within a temperature range of -35°C to +105°C. This cable is designed for industrial control, instrumentation, and PLC/DCS systems, supporting analog and digital signals for sensors, valves, and actuators in indoor and outdoor sunlight-resistant environments.
5311C
The 5311C is an XTRAGUARD 1 shielded multi-conductor cable featuring 7 conductors of 22 AWG tinned copper with semi-rigid PVC insulation and a slate PVC outer jacket. It is designed for industrial control systems, instrumentation, and control circuits, supporting analog and digital signals. The cable is rated for 300 V and operates within a temperature range of -35°C to +105°C.
5326UL
The Belden 5326UL is a riser-class (FPLR) fire alarm cable containing eight 18 AWG solid bare copper conductors with polypropylene insulation and a PVC outer jacket with a ripcord. It is suitable for indoor fire alarm, monitor/detection, and audio/control/notification circuits. The cable is rated for 300 V UL voltage, supports up to 3.5 Amps per conductor, and operates within a temperature range of -20°C to +75°C.
5345FE
The Belden 5345FE is a security and sound cable designed for riser (CMR) environments, featuring 6 pairs of 18 AWG stranded bare copper conductors with polyolefin insulation, a Beldfoil shield, and a PVC jacket. It is rated for 300 V and operates within a temperature range of -20°C to +75°C, suitable for security systems, intercoms, PA systems, and audio applications.
5362C
The Belden 5362C is a shielded, 2-conductor, 16 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and operating temperatures from -30°C to +105°C. It features an overall aluminum/polyester shield and is designed for industrial control systems, instrumentation, and PLC/DCS systems. This cable is suitable for transmitting analog and digital signals to connect sensors, encoders, solenoids, valves, actuators, and positioners in raceways, cable trays, and ducts.
5403FE
The Belden 5403FE is a security and sound riser-CMR cable designed for indoor use in security systems, intercom/PA systems, audio/speaker setups, and power-limited controls. It features five 20 AWG stranded bare copper conductors with polypropylene insulation, a Beldfoil shield, and a PVC jacket with a ripcord. The cable is rated for 300 V (CMR), supports a maximum current of 3 Amps per conductor, and complies with various regulatory standards including UL1666 and RoHS directives.
5422
The Belden 5422 is a 2-conductor, 18 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for a voltage of 600 V and operating temperatures from -30 °C to +105 °C. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, and automation equipment. The cable features a nominal characteristic impedance of 93 Ohm and a conductor-to-conductor capacitance of 23.3 pF/ft, complying with AWM, MTW, and FT4 standards for indoor and outdoor use.
5424
The Belden 5424 is an XTRAGUARD 1 multi-conductor cable featuring four 18 AWG stranded tinned copper conductors with PVC insulation and a slate PVC outer jacket. It is rated for 600 V and operates within a temperature range of -30°C to +105°C. This cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.