Sitemap - 8
87307
The part 87307 is a XTRAGUARD FLEX flexible torsion cable featuring 7 conductors of 18 AWG bare copper with TPE insulation and a black polyurethane outer jacket. It is rated for a voltage of 600 V and operating temperatures from -30°C to +80°C. This cable is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems.
87007CY
The 87007CY is a highly flexible 7-conductor cable with 24 AWG bare copper conductors, TPE insulation, an overall tinned copper shield, and a black polyurethane (TPU) outer jacket. It is rated for 600 V and supports operating temperatures from -30°C to +80°C. This XTRAGUARD FLEX cable is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
86701CY
The Belden 86701CY is a flexible 1-pair 22 AWG tinned copper data cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and a maximum operating temperature of 105°C. This XTRAGUARD FLEX cable is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems.
86514CY
The 86514CY is an XTRAGUARD FLEX continuous flex data cable featuring 14 pairs of 26 AWG tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, tinned copper braid, and a slate PVC outer jacket. It is rated for 300 V and a maximum operating temperature of 105°C, with excellent resistance to sunlight and oils. This cable is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, control panels, automation, and instrumentation systems.
86506CY
The Belden 86506CY is an XTRAGUARD FLEX continuous flex data cable featuring 6 pairs of 26 AWG tinned copper conductors with semi-rigid PVC insulation, overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and supports operating temperatures from -10°C to +105°C. This cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation equipment, and instrumentation systems.
86503CY
The 86503CY is a continuous flex data cable featuring 3 pairs of 26 AWG tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield with 85% tinned copper braid, and a slate PVC outer jacket. It is rated for a voltage of 300 V and supports an operating temperature range of -10°C to +105°C. This cable is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation equipment, and instrumentation systems.
86405CY
The 86405CY is an XTRAGUARD FLEX continuous flex data cable with 5 pairs of 28 AWG tinned copper conductors, semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and a UL temperature of 105°C, and is designed for data, communication, audio, and low-level signal transmission in industrial networking, automation, and instrumentation systems.
86312
Belden 86312 is an XTRAGUARD FLEX continuous flex data cable featuring 12 conductors of 22 AWG tinned copper with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for 300 V and supports an operating temperature range of -10°C to +105°C. This cable is designed for data, communication, audio, low-level signal transmission, industrial networking, and automation equipment.
86303
The Belden 86303 is a flexible, 3-conductor, 22 AWG tinned copper data cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures up to 105°C. It is designed for data, communication, audio, and low-level signal transmission, as well as for use in industrial networking, control panels, automation equipment, and instrumentation systems. It complies with various standards including AWM, CMG, CM, PLTC, and FT4 flammability ratings, and offers sunlight and oil resistance.
86212
The Belden 86212 is a 12-conductor, 24 AWG stranded tinned copper XTRAGUARD FLEX data cable with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for 300 V and operating temperatures from -10°C to +105°C, offering high flexibility and resistance to sunlight and oils. This cable is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems.
86187CY
The 86187CY is an XTRAGUARD FLEX continuous flex data cable featuring seven 18 AWG stranded tinned copper conductors with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 300 V, operates within a temperature range of -10°C to +105°C, and meets various UL, CSA, and NEC compliance standards for PLTC, CM, and CMG applications.
86125CY
The Belden 86125CY is a highly flexible, 25-conductor 26 AWG tinned copper data cable featuring semi-rigid PVC insulation, an overall aluminum/polyester shield with a tinned copper spiral serve, and a slate PVC outer jacket. It is rated for 300 V and operates within a temperature range of -10 °C to +105 °C. This continuous flex cable is designed for data, communication, audio, low-level signal transmission, industrial networking, and instrumentation systems.
86118CY
The 86118CY is an 18-conductor, 26 AWG tinned copper flexible data cable with PVC semi-rigid insulation and an overall aluminum/polyester shield with a slate PVC outer jacket. It is rated for a voltage of 300 V and an operating temperature range of -10°C to +105°C. This cable is designed for data, communication, audio, low-level signal transmission, industrial networking, control panels, automation equipment, and instrumentation systems.
86107CY
The Belden 86107CY is a continuous flex data cable featuring 7 conductors of 26 AWG tinned copper with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and operating temperatures from -10°C to +105°C, with a nominal outer diameter of 0.237 in (6.02 mm). This XTRAGUARD FLEX cable is designed for data, communication, audio, low-level signal transmission, industrial networking, and automation equipment.
86102
The part 86102 is a XTRAGUARD FLEX 2-conductor, 26 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and an operating temperature range of -10°C to +105°C. It is designed for continuous flex data transmission, suitable for data, communication, audio, and low-level signal transmission, as well as industrial networking, control panels, automation equipment, and instrumentation systems.
86025CY
The 86025CY is a 25-conductor, 28 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket, rated for 300 V and continuous flex use up to 105°C. It is designed for data, communication, audio, and low-level signal transmission, and is suitable for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
86012CY
The Belden 86012CY is an XTRAGUARD FLEX continuous flex data cable featuring 12 conductors of 28 AWG (7x36) tinned copper with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V with an operating temperature range of -10°C to +105°C, and is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems. The cable meets various regulatory standards including AWM 2661, CMG, CM, CSA FT4, and UL FT4 flammability ratings, and offers sunlight and oil resistance.
86007
The Belden 86007 is a 7-conductor, 28 AWG tinned copper XTRAGUARD FLEX continuous flex data cable with a 300 V rating and a 105°C temperature limit. It features semi-rigid PVC insulation and a slate PVC outer jacket, offering resistance to sunlight and oil. This cable is designed for low-level signal transmission, data and communication systems, industrial networking, and automation equipment.
86004
The Belden 86004 is a flexible, 4-conductor 28 AWG tinned copper cable with semi-rigid PVC insulation and a slate PVC outer jacket, rated for 300 V and a maximum operating temperature of 105°C. It is designed for data, communication, audio, and low-level signal transmission in industrial environments. Typical uses include industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
86002
The Belden 86002 is an XTRAGUARD FLEX continuous flex data cable featuring two 28 AWG tinned copper conductors with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for 300 V with a maximum operating temperature of 105°C and offers a nominal characteristic impedance of 110 Ohm. This cable is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, and instrumentation systems.