Sitemap - 4
45279
Belden part 45279 is an XTRAGUARD 4 cable built with 9 pairs of 24 AWG (7x32) stranded tinned copper conductors, TPE insulation, an overall aluminum/polyester shield plus 70% tinned copper braid, and a slate TPE outer jacket with ripcord. It is rated 300 V under AWM 20237/AWM 21918 and CSA AWM, with a UL temperature rating of 125°C and an operating range of -50°C to +125°C. The datasheet lists suitable applications including data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45275
Belden part 45275 is an XTRAGUARD 4 cable containing 5 pairs of 24 AWG (7x32) stranded tinned copper conductors with TPE insulation, an overall aluminum/polyester tape shield (100% coverage) plus a 70% tinned copper braid, and a slate TPE outer jacket with ripcord. It is rated 300 V under AWM styles 20237 and 21918 and CSA AWM, with a UL temperature rating of 125 °C. Suitable applications include data, communication, audio, and low-level signal transmission for industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45273
Belden part 45273 is an XTRAGUARD 4 cable containing 3 pairs of 24 AWG (7x32) stranded tinned copper conductors with TPE insulation, an overall aluminum/polyester shield plus 70% tinned copper braid, and a slate TPE outer jacket with ripcord. It is rated 300 V (AWM 20237 / AWM 21918 / CSA AWM), UL 125 °C, with an operating temperature range of -50 °C to +125 °C. It is intended for data, communication, audio, and low-level signal transmission, including industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45198
The Belden 45198 is an XTRAGUARD 4 cable with 8 conductors of 22 AWG (7/30) tinned copper, TPE insulation, an overall aluminum/polyester bi-laminate shield with 100% coverage, and a slate TPE outer jacket. It is rated 300 V for PLTC/AWM/CSA use and is suitable for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45193
Belden part 45193 is an XTRAGUARD 4 cable with 3 conductors of 22 AWG (7x30) tinned copper, TPE insulation, an overall aluminum/polyester shield with 100% coverage and a 22 AWG drainwire, and a slate TPE outer jacket with ripcord. It is rated 300 V for PLTC and AWM use, operates from -50°C to +125°C, and is intended for data, communication, audio, low-level signal, industrial networking, serial communication, control panel, automation equipment, and instrumentation systems.
45192
Belden part 45192 is an XTRAGUARD 4 two-conductor cable with 22 AWG (7/30) tinned copper conductors, TPE insulation, an overall aluminum/polyester foil shield with 100% coverage, and a slate TPE outer jacket. It is rated 300 V and is intended for data, communication, audio, and low-level signal transmission in applications such as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45178
Belden part 45178 is an XTRAGUARD 4 cable with eight 16 AWG stranded tinned copper conductors, TPE insulation, an overall shield, and a slate TPE outer jacket. It is rated 300 V and is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45172
Belden part 45172 is a 2-conductor 16 AWG (19x29) tinned copper XTRAGUARD 4 cable with TPE insulation, an overall aluminum/polyester shield plus a 70% tinned copper braid with a 16 AWG drainwire, and a slate TPE outer jacket with ripcord. It is rated 300 V (PLTC/AWM) with an operating temperature of -50 °C to +125 °C and is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45156
The Belden 45156 is an XTRAGUARD 4 cable with six 20 AWG (7x28) tinned copper conductors, TPE insulation, an overall shield, and a slate TPE outer jacket. It is rated 300 V for PLTC and AWM styles 20237/21918, with UL temperature rating of 125 °C and an operating range of -50 °C to +125 °C. It is intended for data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45132
Belden part 45132 is an XTRAGUARD 4 cable constructed with two pairs of 18 AWG (16x30) tinned copper conductors, TPE insulation, and a slate TPE outer jacket. It includes an overall aluminum/polyester foil shield with 100% coverage plus a 70% tinned copper braid and an 18 AWG drainwire. The cable is rated for 300 V, operates from -50 °C to +125 °C, and is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45131
Belden 45131 is an XTRAGUARD 4 single-pair cable built with 18 AWG (16x30) tinned copper conductors, TPE insulation, an overall aluminum/polyester shield with 100% tape coverage plus a 70% tinned copper braid, and a slate TPE outer jacket with a ripcord. It is rated 300 V for PLTC and AWM styles, with a UL temperature rating of 125 °C and an operating range of -50 °C to +125 °C. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45126
Belden 45126 is an XTRAGUARD 4 cable containing six 22 AWG (7x30) tinned copper pairs with TPE insulation, an overall aluminum/polyester shield plus 70% tinned copper braid, and a slate TPE jacket with ripcord. It is rated 300 V for PLTC and AWM applications, with a 125 °C UL temperature rating and -50 °C to +125 °C operating range. Suitable uses include data, communication, audio, and low-level signal transmission; industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45122
Belden 45122 is an XTRAGUARD 4 cable containing 2 pairs of 22 AWG (7x30) stranded tinned copper conductors with TPE insulation, an overall aluminum/polyester shield plus tinned copper braid, and a slate TPE outer jacket. It is rated 300 V for PLTC and AWM styles and is intended for data, communication, audio, low-level signal transmission, industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable has a nominal overall diameter of 0.325 in (8.26 mm), an operating temperature range of -50 °C to +125 °C, and includes a ripcord.
45120
Belden part 45120 is an XTRAGUARD 4 cable containing 10 conductors of 24 AWG (7x32) tinned copper with TPE insulation, an overall bi-laminate aluminum/polyester and tinned copper braid shield, and a slate TPE outer jacket. It is rated for 300 V and operation from -50 °C to +125 °C, and is intended for data, communication, audio, low-level signal, industrial networking, serial communication, control panel, automation equipment, and instrumentation applications.
45103
The Belden 45103 is an XTRAGUARD 4 cable with three 22 AWG (7x30) tinned copper conductors, TPE insulation, and an overall shield with a 22 AWG tinned copper drainwire, finished with a slate TPE jacket and ripcord. It is rated 300 V for PLTC and AWM use and 125 °C, intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45102
Belden part 45102 is an XTRAGUARD 4 cable with 2 conductors of 22 AWG (7x30) tinned copper, TPE insulation, an overall aluminum/polyester foil shield (100% coverage) with a 22 AWG tinned copper drainwire plus a 70% tinned copper braid, and a slate TPE outer jacket with ripcord. It is rated 300 V (UL PLTC, AWM 20237/21918; CSA AWM) with a UL temperature rating of 125°C and an operating range of -50°C to +125°C. It is intended for data, communication, audio, low-level signal, industrial networking, serial communication, control panel, automation equipment, and instrumentation applications.
45098
The Belden 45098 is an XTRAGUARD 4 cable with eight 24 AWG (7x32) stranded tinned-copper conductors, TPE insulation, an overall aluminum/polyester bi-laminate shield with a tinned-copper drainwire, and a slate TPE outer jacket. It is rated 300 V and 125 °C (UL), with an operating temperature range of -50 °C to +125 °C. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45096
The Belden 45096 is an XTRAGUARD 4 cable with six 24 AWG (7x32) tinned copper conductors, TPE insulation, and an overall aluminum/polyester shield with 100% coverage and a tinned copper drainwire. It has a slate TPE outer jacket with ripcord, a nominal diameter of 0.261 in (6.63 mm), and is rated 300 V with UL temperature 125 °C and an operating range of -50 °C to +125 °C. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45093
The Belden 45093 is an XTRAGUARD 4 3-conductor cable built with 24 AWG (7x32) tinned copper conductors, TPE insulation, an overall aluminum/polyester shield with 100% coverage, and a slate TPE outer jacket with ripcord. It is rated 300 V for AWM styles 20237/21918 and CSA AWM, with a UL temperature rating of 125 °C and an operating range of -50 °C to +125 °C. It is intended for data, communication, audio, and low-level signal transmission in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
45074
Belden part 45074 is an XTRAGUARD 4 cable with four 16 AWG stranded tinned copper conductors, TPE insulation, and a slate TPE outer jacket. It is rated 300 V for PLTC and AWM 21916 use, sunlight resistant (black only), and intended for data, communication, audio, low-level signal, industrial networking, serial communication, control panel, automation, and instrumentation applications. The cable has a nominal overall diameter of 0.314 in (7.98 mm) and operates from -50 °C to +125 °C.