No preview available
Download the PDF to view the complete datasheet
UPL1-1-61-103-M Key Specifications
- Current Rating
- 10
- Max Operating Temperature
- 85 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Toggle
- Number of Poles
- 1
- Trip Time
- 0.18s to 1.8s
- Type
- Hydraulic Magnetic
UPL1-1-61-103-M Pinout & Package
- Number of Terminals
- 2
- Mounting
- Panel Mount
Other Sensata parts
- 219-3-1REC4-66-5-9-3 — Circuit Breaker Hydraulic Magnetic 3Pole 3A 277VAC/480VAC
- AP1-1-65F-802 — Hydraulic Magnetic Switch, 240VAC, 8A, Handle Actuator, -40 to 100°C
- 209-2-1REC4-52-2-9-60 — Hydraulic Magnetic Relay, 2-Pole, 125VDC, 60A, Panel Mount, 0.7s to 20s Trip Tim...
- JLE-1-0-SW-3-F1-125 — Circuit Breaker Magnetic 1Pole 125A 160VDC
- JLM-2-1-62-5-B3-175 — Circuit Breaker Magnetic 2Pole 175A 240VAC
- PSA-5-N — Circuit Breaker Thermal 5A 30VDC
- 203-2-1-62-102-4-3-1 — Supplementary Protector
- 209-2-1-52-2-8-5 — Circuit Breaker Magnetic 2Pole 5A 125VDC
More Circuit Breakers
- BU2FHC-090Y1WKR6 — Circuit Breaker Thermal Magnetic 2Pole 90A 600VAC
- BU2EHC-030LW2KFQ — Circuit Breaker Thermal Magnetic 2Pole 30A 12VDC
- BU3FHC-015Y1W2KRN — Circuit Breaker Thermal Magnetic 3Pole 15A 48VDC
- AA1-B0-12-425-1G1-C — Hydraulic Magnetic Circuit Breaker
- BU2FHC-090LWKRJ — Circuit Breaker Thermal Magnetic 2Pole 90A 125VDC
- FT1-B2-12-815-32A-BG — Circuit Breaker Hydraulic Magnetic 1Pole 150A 125VDC
- CMB-063-11CNN-W-A — Thermal Circuit Breaker, 125VAC/250VAC/32VDC, 6A, 5-35s Trip Time, Panel Mount
- 19108-04M — Circuit Breaker Thermal 1Pole 8A 14VDC
UPL1-1-61-103-M FAQ
What is UPL1-1-61-103-M?
UPL1-1-61-103-M is a Circuit Breaker from Sensata. Circuit Breaker Magnetic 1Pole 10A.
Who manufactures UPL1-1-61-103-M?
UPL1-1-61-103-M is manufactured by Sensata.
What package and pinout does UPL1-1-61-103-M have?
UPL1-1-61-103-M comes in 2 pins, panel mount mounting.
What is the operating temperature range of UPL1-1-61-103-M?
UPL1-1-61-103-M operates from -40 °C to 85 °C.
Specifications
- Manufacturer
- Sensata
Ask AI Assistant
Ask questions about UPL1-1-61-103-M specifications
Click to ask a quick question:
Parameters
| Actuator Type | Toggle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 82647 |
| Current Rating | 10 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200020 |
| Max Operating Temperature | 85 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 1 |
| Number of Terminals | 2 |
| PPAP | No |
| Radiation Hardening | No |
| RoHS Versions | 2011/65/EU |
| Schedule B | 8536200020 |
| Trip Time | 0.18s to 1.8s |
| Type | Hydraulic Magnetic |