PG-100N-103R Key Specifications
- Battery Voltage Rating
- 1.5
- Max Operating Temperature
- 50 °C
- Min Operating Temperature
- 0 °C
- Display Type
- LCD
- Style
- Handheld
- Type
- Digital Manometer
Characteristics (datasheet)
- Model number (型式)
- PG-100N-103R-****, PG-100N-103R-M ****, PG-100N-103R-W ****
- Pressure reference (形(指示方式))
- ゲージ圧(連成圧) Gauge(Compound)
- Rated pressure range (定格圧力)
- − 100 ~ 1000 kPa
- Maximum pressure (最大圧力)
- 1500 kPa
- Break-down pressure (破壊圧力)
- 2000 kPa
- Rated display range (定格表示)
- − 100 ~ 1000 / −. 100 ~ 1.000
- Integrated accuracy (総合精度)
- ± 0.5 %F.S. ± 2 digits (at 25 °C ± 5 °C) / ± 1.0 %F.S. ± 2 digits (at 25 °C ± 25 °C)
- Net weight (質量)
- 約 100 g / Approx. 100 g
- Power (電源)
- 単 4 形乾電池、DC1.5 V × 2 電池寿命 1000 時間以上 / AAA dry battery DC 1.5 V × 2 Battery life 1000 h minimum
Other Nidec parts
- PG-100B-102A-WX1 — HANDHELD DIGITAL MANOMETER
- PG-100B-102A-X1T — HANDHELD DIGITAL MANOMETER
- FGE-50X — GAUGE, DIGITAL FORCE, 100LBF, 0.2%; Force Capacity:50lbf; Resolution (g):0.01kg;...
- PG-100B-102R-H — HANDHELD DIGITAL MANOMETER
- PG-100B-102R-HX2T — HANDHELD DIGITAL MANOMETER
- PG-100N-102R-WX1 — HANDHELD DIGITAL MANOMETER
- PG-100N-102R-T — HANDHELD DIGITAL MANOMETER
- PG-100N-101R-WX1T — HANDHELD DIGITAL MANOMETER
More Test Equipment
- K3NXVD1A — Accessories Process Meter
- PCSU1000 — TWO-CHANNEL USB PC OSCILLOSCOPE
- FLUKE-700RG31 — Fluke 700RG31 Pressure Gauge, Reference, 10000 PSIG
- 4084AWG — Arbitrary Waveform Generator, 20MHz Bandwidth, 200MS/s Sampling Rate
- DPO2012B — 100MHz 2-Channel Digital Oscilloscope with USB, Ethernet, and VGA Interface
- AFG3101C — Function Generators u0026 Synthesizers Arbitrary Function Generator 1Ch 100MHz
- W9212 — Lufkin; 1/2 in.x12 ft. Mezurall Power Return Tape
- TMULD-300 — BEHA-AMPROBE TMULD-300 ULTRASONIC LEAK DETECTOR KIT
PG-100N-103R FAQ
What is PG-100N-103R?
PG-100N-103R is a Test Equipment from Nidec. Digital Manometer Handheld 1.5V.
Who manufactures PG-100N-103R?
PG-100N-103R is manufactured by Nidec.
What is the operating temperature range of PG-100N-103R?
PG-100N-103R operates from 0 °C to 50 °C.
Where can I download the PG-100N-103R datasheet PDF?
The PG-100N-103R datasheet PDF (152 KB) can be downloaded free from this page using the Download PDF button.
Specifications
- Manufacturer
- Nidec
- Category
- Test MeasurementTest Equipment
- File Size
- 152 KB
Ask AI Assistant
Ask questions about PG-100N-103R specifications
Click to ask a quick question:
Parameters
| AEC Qualified | No |
| Automotive | No |
| Battery Voltage Rating | 1.5 |
| Cage Code | SDM11 |
| Display Type | LCD |
| ECCN | EAR99 |
| EU RoHS | Yes |
| Max Operating Temperature | 50 |
| Min Operating Temperature | 0 |
| PPAP | No |
| RoHS Versions | 2011/65/EU |
| Style | Handheld |
| Type | Digital Manometer |