IPGH66-1-62-303-90 Datasheet
2-Pole Hydraulic Magnetic Circuit Breaker, 277VAC, 30A, Panel Mount
IPGH66-1-62-303-90 Key Specifications
- Current Rating
- 30
- Voltage Rating
- 277VAC
- Max Operating Temperature
- 85 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Handle
- Number of Poles
- 2
- Trip Time
- 2s to 20s
- Type
- Hydraulic Magnetic
IPGH66-1-62-303-90 Pinout & Package
- Number of Terminals
- 4
- Mounting
- Panel Mount
- Terminal Design
- Screw
The full pin configuration and pin descriptions are in the IPGH66-1-62-303-90 PDF datasheet above.
IPGH66-1-62-303-90 Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
A12-B0-24-630-531-C
Circuit Breaker Hydraulic Magnetic 2Pole 30A 277VAC
A12-B0-34-630-331-C
2-Pole Hydraulic Magnetic Switch, 277VAC/80VDC, 30A, 0.6s-20s Trip Time, Panel Mount
219-2-1REC4-61-5-7-30-H
Circuit Breaker Magnetic 2Pole 30A 480VAC
Similar parts
Matching key ratings; package or pinout may differ.
IPGH11-1-65F-303-00
Circuit Breaker Hydraulic Magnetic 2Pole 30A 277VAC
A12-B0-34-630-131-C
Circuit Breaker Hydraulic Magnetic 2Pole 30A 277VAC/80VDC
219-2-1-65-5-8-20-AH-V
Hydraulic Magnetic 2-Pole 480VAC 30A Toggle Switch, Panel Mount, 4-Terminal Stud
219-2-1-65-8-8-30
Hydraulic Magnetic Circuit Breaker, 2P, 480VAC, 30A, Panel Mount
Check pinout and ratings in both datasheets before substituting.
Other Sensata parts
- 219-3-1-65-5-9-80 — Hydraulic Magnetic 3-Pole 480VAC 80A Toggle Switch
- UPL111-1REC5-66-303 — Circuit Breaker Magnetic 3Pole 30A
- APL111-1REC4-41-303-AM — Circuit Breaker Magnetic 3Pole 30A
- 219-3-1REC5-65-5-8-15-AH-V — Hydraulic Magnetic 3-Pole 480VAC 15A Toggle Switch
- PDLA-70 — Circuit Breaker Thermal 70A 30VDC
- UPGH111-1-66-302-01 — Circuit Breaker Magnetic 3Pole 3A
- UPG1-1-62-302-90 — Hydraulic Magnetic Switch, 3A, 2s to 20s Trip Time, Panel Mount
- 209-3-1-41-4-9-100 — Circuit Breaker Hydraulic Magnetic 3Pole 100A 240VAC
More Circuit Breakers
- BU3FHC-070LWKFM — Circuit Breaker Thermal Magnetic 3Pole 70A 24VDC
- BU2EHC-0150LWKF2 — Circuit Breaker Thermal Magnetic 2Pole 150A 480VAC/250VDC
- BU3FHC-045L1W2KR1 — Circuit Breaker Thermal Magnetic 3Pole 45A 120VAC
- CA1X010891121C/RB1306BU1C — Hydraulic Magnetic Circuit Breaker
- MT1-M-74-615-3-A23-B-J — Circuit Breaker Hydraulic Magnetic 1Pole 15A 80VDC Automotive
- S-TS800HU-FTU-LL-600 — Circuit Breaker Thermal Magnetic 3Pole 600A 600VAC
- BU2FHC-0125Y1WKR2 — Circuit Breaker Thermal Magnetic 2Pole 125A 240VAC
- BU3FHC-080Y1W2KR1 — Circuit Breaker Thermal Magnetic 3Pole 80A 120VAC
IPGH66-1-62-303-90 FAQ
What is IPGH66-1-62-303-90?
IPGH66-1-62-303-90 is a Circuit Breaker from Sensata. 2-Pole Hydraulic Magnetic Circuit Breaker, 277VAC, 30A, Panel Mount.
Who manufactures IPGH66-1-62-303-90?
IPGH66-1-62-303-90 is manufactured by Sensata.
What package and pinout does IPGH66-1-62-303-90 have?
IPGH66-1-62-303-90 comes in 4 pins, panel mount mounting. The pin configuration and pin descriptions are given in the PDF datasheet.
What is the operating temperature range of IPGH66-1-62-303-90?
IPGH66-1-62-303-90 operates from -40 °C to 85 °C.
Where can I download the IPGH66-1-62-303-90 datasheet PDF?
The IPGH66-1-62-303-90 datasheet PDF (1 MB) can be downloaded free from this page using the Download PDF button.
What are the equivalents or alternatives to IPGH66-1-62-303-90?
Parts with a similar function (Circuit Breaker) include A12-B0-24-630-531-C, A12-B0-34-630-331-C, 219-2-1REC4-61-5-7-30-H. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Sensata
- File Size
- 1 MB
Ask AI Assistant
Ask questions about IPGH66-1-62-303-90 specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 82647 |
| Current Rating | 30 |
| ECCN | EAR99 |
| EU RoHS | Yes with Exemption |
| HTS Code | 8536200040 |
| Max Operating Temperature | 85 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 2 |
| Number of Terminals | 4 |
| PPAP | No |
| RoHS Versions | 2011/65/EU |
| Terminal Design | Screw |
| Trip Time | 2s to 20s |
| Type | Hydraulic Magnetic |
| Voltage Rating | 277VAC |