FT3-MA-14-860-22A-BT Datasheet
Carling TechnologiesCircuit Breaker
3-Pole Hydraulic Magnetic Circuit Breaker, 125VDC, 600A, Panel Mount
No preview available
Download the PDF to view the complete datasheet
FT3-MA-14-860-22A-BT Key Specifications
- Current Rating
- 600
- Voltage Rating
- 125VDC
- Max Operating Temperature
- 85 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Handle
- Number of Poles
- 3
- Trip Time
- 2.5s to 15s
- Type
- Hydraulic Magnetic
FT3-MA-14-860-22A-BT Pinout & Package
- Number of Terminals
- 8
- Mounting
- Panel Mount
- Terminal Design
- Screw
FT3-MA-14-860-22A-BT Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
FA3-PB-14-860-22A-BT
Hydraulic Magnetic Relay, 3-Pole, 125VDC, 600A, 2.5s-15s Trip Time, Panel Mount
FA3-P0-14-860-22A-BT
3-Pole Hydraulic Magnetic Circuit Breaker, 125VDC, 600A, Panel Mount
FA3-PB-14-860-42B-BT
Circuit Breaker Hydraulic Magnetic 3Pole 600A 125VDC
FA3-P0-16-860-22A-BT
Circuit Breaker Hydraulic Magnetic 3Pole 600A 125VDC
FA3-PB-14-860-42A-BT
Circuit Breaker Hydraulic Magnetic 3Pole 600A 125VDC
Similar parts
Matching key ratings; package or pinout may differ.
FA3-PB-14-860-32A-BT
Circuit Breaker Hydraulic Magnetic 3Pole 600A 125VDC
JTEP-3-1-53-3-F1-600
Circuit Breaker Magnetic 3Pole 600A 160VDC
Check pinout and ratings in both datasheets before substituting.
Other Carling Technologies parts
- C1005B-3B071BR3 — Circuit Breaker Thermal 1Pole 7A 125VAC/250VAC/32VDC
- C1005B-3B121BR3 — Thermal Rocker Switch, 125VAC/250VAC/32VDC, 12A, 5-35s Trip Time, Snap-In Mount
- FA2-B0-14-912-12A-BG — Hydraulic Magnetic Circuit Breaker, 125VDC, 125A, 2.5-15s Trip Time, Panel Mount
- DA1-B0-34-620-121-C — Circuit Breaker Hydraulic Magnetic 1Pole 20A 277VAC/65VDC
- PBA-BC-26-620-1PA-AG — Circuit Breaker Equipment Leakage 1Pole 20A 120VAC
- PDC-B-24-650-E-2A3-1-C — Circuit Breaker Equipment Leakage 2Pole 50A 120VAC/280VAC
- AA1-B0-14-425-2G1-C — Hydraulic Magnetic Circuit Breaker
- QF1-B-94-425-1-EF2-B-C — Circuit Breaker Magnetic 1Pole 2.5A 250VAC/125VAC/65VDC
More Circuit Breakers
- 203-2-1-63F-752-4-1-2 — Supplementary Protector
- BU3FHC-015LW2KFM — Circuit Breaker Thermal Magnetic 3Pole 15A 24VDC
- 209-2-1-52-2-8-50-H — Hydraulic Magnetic Circuit Breaker 125VDC 50A 0.7s-20s Trip Time Panel Mount
- 205-11-1-66-6-502-O — Circuit Breaker Magnetic 2Pole 5A 277VAC
- BU3FHC-025Y1WKR6 — Circuit Breaker Thermal Magnetic 3Pole 25A 600VAC
- UPG1-1-51F-183-A-21 — Hydraulic Magnetic Circuit Breaker, 18A, 1.2s to 12s Trip Time, Panel Mount
- BU2FHC-060LWKF2 — Circuit Breaker Thermal Magnetic 2Pole 60A 480VAC/250VDC
- 209-2-1-53-2-8-30-V — Circuit Breaker Magnetic 2Pole 30A 125VDC
FT3-MA-14-860-22A-BT FAQ
What is FT3-MA-14-860-22A-BT?
FT3-MA-14-860-22A-BT is a Circuit Breaker from Carling Technologies. 3-Pole Hydraulic Magnetic Circuit Breaker, 125VDC, 600A, Panel Mount.
Who manufactures FT3-MA-14-860-22A-BT?
FT3-MA-14-860-22A-BT is manufactured by Carling Technologies.
What package and pinout does FT3-MA-14-860-22A-BT have?
FT3-MA-14-860-22A-BT comes in 8 pins, panel mount mounting.
What is the operating temperature range of FT3-MA-14-860-22A-BT?
FT3-MA-14-860-22A-BT operates from -40 °C to 85 °C.
What are the equivalents or alternatives to FT3-MA-14-860-22A-BT?
Parts with a similar function (Circuit Breaker) include FA3-PB-14-860-22A-BT, FA3-P0-14-860-22A-BT, FA3-PB-14-860-42B-BT. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Carling Technologies
Ask AI Assistant
Ask questions about FT3-MA-14-860-22A-BT specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 73559 |
| Current Rating | 600 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 85 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 3 |
| Number of Terminals | 8 |
| PPAP | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Screw |
| Trip Time | 2.5s to 15s |
| Type | Hydraulic Magnetic |
| Voltage Rating | 125VDC |