FA1-B0-16-810-32A-BG Datasheet
Carling TechnologiesCircuit Breaker
Hydraulic Magnetic Circuit Breaker, 125VDC, 100A, Panel Mount
FA1-B0-16-810-32A-BG Key Specifications
- Current Rating
- 100
- Voltage Rating
- 125VDC
- Max Operating Temperature
- 85 °C
- Min Operating Temperature
- -40 °C
- Actuator Type
- Handle
- Number of Poles
- 1
- Trip Time
- 22s to 150s
- Type
- Hydraulic Magnetic
FA1-B0-16-810-32A-BG Pinout & Package
- Number of Terminals
- 2
- Mounting
- Panel Mount
- Terminal Design
- Box Wire Connector
The full pin configuration and pin descriptions are in the FA1-B0-16-810-32A-BG PDF datasheet above.
FA1-B0-16-810-32A-BG Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
Similar parts
Matching key ratings; package or pinout may differ.
FA1-B2-14-810-42A-BG
125VDC 100A Hydraulic Magnetic Circuit Breaker Panel Mount
209-1-1-52-2-6-100
Hydraulic Magnetic Switch, 125VDC, 100A, 0.7s to 20s Trip Time, Panel Mount
FA1-B0-14-810-12A-BG
Circuit Breaker Hydraulic Magnetic 1Pole 100A 125VDC
209-1-1-52-2-2-100-H
Hydraulic Magnetic Switch, 125VDC, 100A, 0.7s to 20s Trip Time, Panel Mount
FA1-B0-14-810-42A-BG
125VDC Hydraulic Magnetic Switch, Panel Mount, 100A, 2.5s to 15s Trip Time
FA1-B9-14-810-22A-BG
125VDC 100A Hydraulic Magnetic Circuit Breaker with Handle Actuator
Check pinout and ratings in both datasheets before substituting.
Other Carling Technologies parts
- CT1X013521311MG/RB1120CT1G — Hydraulic Magnetic Circuit Breaker
- CA1B212675321C/RB1120CU1C — Hydraulic Magnetic Circuit Breaker
- AA1-B0-20-650-5B3-C — Hydraulic Magnetic Circuit Breaker
- B21-B0-24-620-11E-K3 — Circuit Breaker Hydraulic Magnetic 1Pole 20A 120VAC
- AA1-F0-14-425-1D1-C — Hydraulic Magnetic Circuit Breaker
- MG2-B-20-425-1-BA3-B-B — Hydraulic Magnetic Circuit Breaker
- PBB-BC-24-625-21A-AG — Circuit Breaker Equipment Leakage 2Pole 25A 120VAC/240VAC
- A12-B2-34-620-M1A-I — Circuit Breaker Hydraulic Magnetic 2Pole 20A 250VAC/65VDC
More Circuit Breakers
- BU2EHC-015L1WKRN — Circuit Breaker Thermal Magnetic 2Pole 15A 48VDC
- BU2EHC-0100L1WKF6 — Circuit Breaker Thermal Magnetic 2Pole 100A 480VAC/250VDC
- ESX10TA100DC 24 V12 A — Circuit Breaker Electronic 12A 24VDC
- BU2EHC-0150L1WKRN — Circuit Breaker Thermal Magnetic 2Pole 150A 48VDC
- BU3EHC-050LW2KR2 — Circuit Breaker Thermal Magnetic 3Pole 50A 240VAC
- BU2EHC-040LWKR2 — Circuit Breaker Thermal Magnetic 2Pole 40A 240VAC
- BU2EHC-020Y1W2KRN — Circuit Breaker Thermal Magnetic 2Pole 20A 48VDC
- AP17-1-72-302 — Circuit Breaker Hydraulic Magnetic 2Pole 3A 240VAC
FA1-B0-16-810-32A-BG FAQ
What is FA1-B0-16-810-32A-BG?
FA1-B0-16-810-32A-BG is a Circuit Breaker from Carling Technologies. Hydraulic Magnetic Circuit Breaker, 125VDC, 100A, Panel Mount.
Who manufactures FA1-B0-16-810-32A-BG?
FA1-B0-16-810-32A-BG is manufactured by Carling Technologies.
What package and pinout does FA1-B0-16-810-32A-BG have?
FA1-B0-16-810-32A-BG comes in 2 pins, panel mount mounting. The pin configuration and pin descriptions are given in the PDF datasheet.
What is the operating temperature range of FA1-B0-16-810-32A-BG?
FA1-B0-16-810-32A-BG operates from -40 °C to 85 °C.
Where can I download the FA1-B0-16-810-32A-BG datasheet PDF?
The FA1-B0-16-810-32A-BG datasheet PDF (3 MB) can be downloaded free from this page using the Download PDF button.
What are the equivalents or alternatives to FA1-B0-16-810-32A-BG?
Parts with a similar function (Circuit Breaker) include FA1-B2-14-810-32A-BG, FA1-B2-14-810-42A-BG, 209-1-1-52-2-6-100. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Carling Technologies
- File Size
- 3 MB
Ask AI Assistant
Ask questions about FA1-B0-16-810-32A-BG specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 73559 |
| Current Rating | 100 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 85 |
| Min Operating Temperature | -40 |
| Mounting | Panel Mount |
| Number of Poles | 1 |
| Number of Terminals | 2 |
| PPAP | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Box Wire Connector |
| Trip Time | 22s to 150s |
| Type | Hydraulic Magnetic |
| Voltage Rating | 125VDC |