CMB-083-11CNN-W-A Datasheet
Carling TechnologiesCircuit Breaker
Circuit Breaker Thermal 1Pole 8A 125VAC/250VAC/32VDC
No preview available
Download the PDF to view the complete datasheet
CMB-083-11CNN-W-A Key Specifications
- Current Rating
- 8
- Voltage Rating
- 125VAC|250VAC|32VDC
- Max Operating Temperature
- 60 °C
- Min Operating Temperature
- -10 °C
- Actuator Type
- Push to Reset
- Number of Poles
- 1
- Trip Time
- 5s to 35s
- Type
- Thermal
CMB-083-11CNN-W-A Pinout & Package
- Number of Terminals
- 2
- Mounting
- Panel Mount
- Terminal Design
- Quick Connect
CMB-083-11CNN-W-A Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
CMB-083-12HNN-B-A
Thermal Circuit Breaker, 125VAC, 250VAC, 32VDC, 8A, 5-35s Trip Time
CMB-083-27GNN-B-A
Thermal Switch 125V 250V 32V 8A 5-35s Trip Time Panel Mount
CMB-083-00ENN-B-A
Circuit Breaker Thermal 1Pole 8A 125VAC/250VAC/32VDC
CMB-083-27GNN-W-A
Circuit Breaker Thermal 1Pole 8A 125VAC/250VAC/32VDC
CMB-083-11DNN-W-A
Thermal Overload Protector 125VAC 250VAC 32VDC 8A 5-35s Trip Time Panel Mount
CMB-083-27G3N-B-A
Circuit Breaker Thermal 1Pole 8A 125VAC/250VAC/32VDC
Check pinout and ratings in both datasheets before substituting.
Other Carling Technologies parts
- PDP-B-24-450-C-1AD-1-A — 3-Pole 480VAC Equipment Leakage Circuit Breaker, DIN Rail Mount, 5A
- MA1-M-14-450-1-A22-B-T — Circuit Breaker Hydraulic Magnetic 1Pole 5A 80VDC Automotive
- CMB-053-00ENN-B-A — Circuit Breaker Thermal 1Pole 5A 125VAC/250VAC/32VDC
- A12-B0-46-610-212-E — Circuit Breaker Hydraulic Magnetic 2Pole 10A 250VAC
- GA1-B0-46-610-11-DC — Circuit Breaker Hydraulic Magnetic 1Pole 10A 240VAC
- AA1-B0-26-614-E22-A — Hydraulic Magnetic Circuit Breaker
- MA1-B-24-435-1-A34-B-4 — Hydraulic Magnetic Circuit Breaker
- CLB-153-27ENN-B-J — Circuit Breaker Thermal 1Pole 15A 125VAC/250VAC/32VDC
More Circuit Breakers
- 209-2-1-63-4-8-20 — 240VAC 20A Hydraulic Magnetic Relay, 2-Pole, 20s to 200s Trip Time
- 203-22-1-61-153-4-3-1 — Supplementary Protector
- APL111-1REC4-42-202-AM — Circuit Breaker Magnetic 3Pole
- ESX10TB101DC 24 V2 A — Circuit Breaker Electronic 2A 24VDC
- 219-2-1-65F-8-8-15 — Circuit Breaker Magnetic 2Pole 15A 480VAC
- UPL11-1-66-203-H — Circuit Breaker Magnetic 2Pole 20A
- 203-22-2-63-153-4-1-1 — Supplementary Protector
- JLM-2-1-62-5-B3-200 — Circuit Breaker Magnetic 2Pole 200A 240VAC
CMB-083-11CNN-W-A FAQ
What is CMB-083-11CNN-W-A?
CMB-083-11CNN-W-A is a Circuit Breaker from Carling Technologies. Circuit Breaker Thermal 1Pole 8A 125VAC/250VAC/32VDC.
Who manufactures CMB-083-11CNN-W-A?
CMB-083-11CNN-W-A is manufactured by Carling Technologies.
What package and pinout does CMB-083-11CNN-W-A have?
CMB-083-11CNN-W-A comes in 2 pins, panel mount mounting.
What is the operating temperature range of CMB-083-11CNN-W-A?
CMB-083-11CNN-W-A operates from -10 °C to 60 °C.
What are the equivalents or alternatives to CMB-083-11CNN-W-A?
Parts with a similar function (Circuit Breaker) include CMB-083-12HNN-B-A, CMB-083-27GNN-B-A, CMB-083-00ENN-B-A. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Carling Technologies
Ask AI Assistant
Ask questions about CMB-083-11CNN-W-A specifications
Click to ask a quick question:
Parameters
| Actuator Type | Push to Reset |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 73559 |
| Current Rating | 8 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 60 |
| Min Operating Temperature | -10 |
| Mounting | Panel Mount |
| Number of Poles | 1 |
| Number of Terminals | 2 |
| PPAP | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Quick Connect |
| Trip Time | 5s to 35s |
| Type | Thermal |
| Voltage Rating | 125VAC|250VAC|32VDC |