CMB-073-27GNN-W-A Datasheet
Carling TechnologiesCircuit Breakers
Thermal Overcurrent Protector, 125VAC, 7A, 5-35s Trip Time, Panel Mount
No preview available
Download the PDF to view the complete datasheet
CMB-073-27GNN-W-A Key Specifications
- Current Rating
- 7
- Voltage Rating
- 125VAC|250VAC|32VDC
- Max Operating Temperature
- 60 °C
- Min Operating Temperature
- -10 °C
- Actuator Type
- Push to Reset
- Number of Poles
- 1
- Trip Time
- 5s to 35s
- Type
- Thermal
CMB-073-27GNN-W-A Pinout & Package
- Number of Terminals
- 2
- Mounting
- Panel Mount
- Terminal Design
- Quick Connect
CMB-073-27GNN-W-A Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
CMB-073-11CNN-B-A
Circuit Breaker Thermal 1Pole 7A 125VAC/250VAC/32VDC
CMB-073-11DNN-W-A
Thermal Overload Protector, 125VAC, 250VAC, 32VDC, 7A, 5-35s Trip Time
Similar parts
Matching key ratings; package or pinout may differ.
CMB-073-27G3N-B-J
Circuit Breaker Thermal 1Pole 7A 125VAC/250VAC/32VDC
C1005B-2B071BR9
Circuit Breaker Thermal 1Pole 7A 125VAC/250VAC/32VDC
CLB-073-27E3N-B-J
Circuit Breaker Thermal 1Pole 7A 125VAC/250VAC/32VDC
C1005B-3B071BR3
Circuit Breaker Thermal 1Pole 7A 125VAC/250VAC/32VDC
Check pinout and ratings in both datasheets before substituting.
Other Carling Technologies parts
- PDE-B-20-650-B-2A1-1-C — Equipment Leakage Circuit Breaker, 3 Pole, 50A, 208/240VAC, DIN Rail Mount
- CR366026BA1362J2/BRB130T121 — Hydraulic Magnetic Circuit Breaker
- CLB-073-11CNN-B-A — THERMAL CIRCUIT PROTECTORS
- AA1-B0-12-425-1G1-C — Hydraulic Magnetic Circuit Breaker
- MA1-M-14-630-1-A16-2-J — Circuit Breaker Hydraulic Magnetic 1Pole 30A 80VDC Automotive
- A62- B0- 34 -620- 533- I — Hydraulic Magnetic Switch, 2-Pole, 20A, 250VAC/65VDC, Panel Mount
- CA1B212675321C/RB1120CU1C — Hydraulic Magnetic Circuit Breaker
- PDB-B-24-475-B-2A1-1-C — Equipment Leakage Circuit Breaker 2-Pole 120/240VAC 7.5A DIN Rail
More Circuit Breakers
- BU2FHC-060LW2KRJ — Circuit Breaker Thermal Magnetic 2Pole 60A 125VDC
- 209-3-1REC4-43-4-9-30-A — Circuit Breaker Magnetic 3Pole 30A 240VAC
- SDLM-120-1 — Circuit Breaker Thermal 120A 30VDC
- BU2EHC-0100Y1WKRN — Circuit Breaker Thermal Magnetic 2Pole 100A 48VDC
- BU3EHC-040Y1W2KRJ — Circuit Breaker Thermal Magnetic 3Pole 40A 125VDC
- 203-2-1-62F-203-E-1-13 — Supplementary Protector
- BU3FHC-020L1W2KRG — Circuit Breaker Thermal Magnetic 3Pole 20A 12VDC
- AU-2C3DL — Circuit Breaker Thermal Magnetic 2Pole 3A 250VDC
CMB-073-27GNN-W-A FAQ
What is CMB-073-27GNN-W-A?
CMB-073-27GNN-W-A is a Circuit Breakers from Carling Technologies. Thermal Overcurrent Protector, 125VAC, 7A, 5-35s Trip Time, Panel Mount.
Who manufactures CMB-073-27GNN-W-A?
CMB-073-27GNN-W-A is manufactured by Carling Technologies.
What package and pinout does CMB-073-27GNN-W-A have?
CMB-073-27GNN-W-A comes in 2 pins, panel mount mounting.
What is the operating temperature range of CMB-073-27GNN-W-A?
CMB-073-27GNN-W-A operates from -10 °C to 60 °C.
What are the equivalents or alternatives to CMB-073-27GNN-W-A?
Parts with a similar function (Circuit Breakers) include CMB-073-11CNN-B-A, CMB-073-11DNN-W-A, CMB-073-27G3N-B-J. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Carling Technologies
Ask AI Assistant
Ask questions about CMB-073-27GNN-W-A specifications
Click to ask a quick question:
Parameters
| Actuator Type | Push to Reset |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 73559 |
| Current Rating | 7 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 60 |
| Min Operating Temperature | -10 |
| Mounting | Panel Mount |
| Number of Poles | 1 |
| Number of Terminals | 2 |
| PPAP | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Quick Connect |
| Trip Time | 5s to 35s |
| Type | Thermal |
| Voltage Rating | 125VAC|250VAC|32VDC |