CLB-033-27E3N-W-H Datasheet
Carling TechnologiesCircuit Breaker
Circuit Breaker Thermal 1Pole 3A 125VAC/250VAC/32VDC
No preview available
Download the PDF to view the complete datasheet
CLB-033-27E3N-W-H Key Specifications
- Current Rating
- 3
- Voltage Rating
- 125VAC|250VAC|32VDC
- Max Operating Temperature
- 60 °C
- Min Operating Temperature
- -10 °C
- Actuator Type
- Push to Reset
- Number of Poles
- 1
- Trip Time
- 4s to 40s
- Type
- Thermal
CLB-033-27E3N-W-H Pinout & Package
- Number of Terminals
- 2
- Mounting
- Panel Mount
- Terminal Design
- Screw
CLB-033-27E3N-W-H Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
Similar parts
Matching key ratings; package or pinout may differ.
CMB-033-11DNN-W-A
Circuit Breaker Thermal 1Pole 3A 125VAC/250VAC/32VDC
CMB-033-11CNB-B-A
Circuit Breaker Thermal 1Pole 3A 125VAC/250VAC/32VDC
CMB-033-12HNN-B-A
Circuit Breaker Thermal 1Pole 3A 125VAC/250VAC/32VDC
CMB-033-11CNN-R-A
Circuit Breaker Thermal 1Pole 3A 125VAC/250VAC/32VDC
Check pinout and ratings in both datasheets before substituting.
Other Carling Technologies parts
- FA3-P0-14-850-21A-BA — Circuit Breaker Hydraulic Magnetic 3Pole 500A 125VDC
- PBB-BA-22-625-3BA-EG — Circuit Breaker Equipment Leakage 2Pole 25A 120VAC/240VAC
- AA1-B0-34-425-3B2-C — Hydraulic Magnetic Circuit Breaker
- AA1-B0-34-425-5G2-C — Hydraulic Magnetic Circuit Breaker
- CMB-043-11DNN-W-A — Thermal Overcurrent Protector, 125VAC/250VAC, 4A, 5s-35s Trip Time, Panel Mount
- FA1-B0-14-820-41A-BJ — Circuit Breaker Hydraulic Magnetic 1Pole 200A 125VDC
- PDB-B-26-610-C-2AB-1-C — Circuit Breaker Equipment Leakage 2Pole 10A 120VAC/240VAC
- CA1X013547321MG/RB1120CU1G — Hydraulic Magnetic Circuit Breaker
More Circuit Breakers
- ESX10TA117DC 24 V2 A — Circuit Breaker Electronic 2A 24VDC
- BU2EHC-0125LW2KRM — Circuit Breaker Thermal Magnetic 2Pole 125A 24VDC
- BU3FHC-0150Y1W2KR6 — Circuit Breaker Thermal Magnetic 3Pole 150A 600VAC
- BU3EHC-035LW2KFN — Circuit Breaker Thermal Magnetic 3Pole 35A 48VDC
- BU2FHC-025LW2KR1 — Circuit Breaker Thermal Magnetic 2Pole 25A 120VAC
- UPL11-1-61-403-H — Hydraulic Magnetic Switch, 2-Pole, 40A, Panel Mount, -40 to 85°C
- 3140-F130-P7T1-SGRX-5A — CIRCUIT BREAKER THERMAL OVER CURRENT 3POLE 5A 415V
- 203-2-2-52-202-5-3-15 — Supplementary Protector
CLB-033-27E3N-W-H FAQ
What is CLB-033-27E3N-W-H?
CLB-033-27E3N-W-H is a Circuit Breaker from Carling Technologies. Circuit Breaker Thermal 1Pole 3A 125VAC/250VAC/32VDC.
Who manufactures CLB-033-27E3N-W-H?
CLB-033-27E3N-W-H is manufactured by Carling Technologies.
What package and pinout does CLB-033-27E3N-W-H have?
CLB-033-27E3N-W-H comes in 2 pins, panel mount mounting.
What is the operating temperature range of CLB-033-27E3N-W-H?
CLB-033-27E3N-W-H operates from -10 °C to 60 °C.
What are the equivalents or alternatives to CLB-033-27E3N-W-H?
Parts with a similar function (Circuit Breaker) include CMB-033-27G3N-B-J, CMB-033-11DNN-W-A, CMB-033-11CNB-B-A. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Carling Technologies
Ask AI Assistant
Ask questions about CLB-033-27E3N-W-H specifications
Click to ask a quick question:
Parameters
| Actuator Type | Push to Reset |
| AEC Qualified | No |
| Automotive | No |
| Cage Code | 73559 |
| Current Rating | 3 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 60 |
| Min Operating Temperature | -10 |
| Mounting | Panel Mount |
| Number of Poles | 1 |
| Number of Terminals | 2 |
| PPAP | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Screw |
| Trip Time | 4s to 40s |
| Type | Thermal |
| Voltage Rating | 125VAC|250VAC|32VDC |