BU3FHC-0100LW2KF2 Datasheet
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
No preview available
Download the PDF to view the complete datasheet
BU3FHC-0100LW2KF2 Key Specifications
- Current Rating
- 100
- Voltage Rating
- 600VAC|250VDC
- Max Operating Temperature
- 40 °C
- Min Operating Temperature
- -5 °C
- Number of Poles
- 3
- Type
- Thermal Magnetic
BU3FHC-0100LW2KF2 Pinout & Package
- Number of Terminals
- 6
- Mounting
- Screw Mount
- Terminal Design
- Lug
BU3FHC-0100LW2KF2 Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
BU3EHC-0100LW2KF6
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
BU3FHC-0100LW2KF6
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
Similar parts
Matching key ratings; package or pinout may differ.
BU3FHC-0100L1WKF6
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
BU3EHC-0100Y1W2KF6
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
BU3EHC-0100Y1WKF6
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
BU3EHC-0100L1WKF6
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
BU3FHC-0100Y1WKF6
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
BU3FHC-0100Y1W2KF2
Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC
Check pinout and ratings in both datasheets before substituting.
Other Fuji Electric parts
- BU2FHC-030Y1WKFG — Circuit Breaker Thermal Magnetic 2Pole 30A 250VDC
- BU2FHC-070LW2KFG — Circuit Breaker Thermal Magnetic 2Pole 70A 250VDC
- BU3FHC-0125LWKR6 — Circuit Breaker Thermal Magnetic 3Pole 125A 600VAC
- BU2FHC-0100Y1WKRG — Circuit Breaker Thermal Magnetic 2Pole 100A 12VDC
- BU3EHC-050Y1W2KRJ — Circuit Breaker Thermal Magnetic 3Pole 50A 125VDC
- BU2EHC-030Y1W2KR6 — Thermal Magnetic Switch 2-Pole 600VAC 30A -5 to 40°C
- BU2FHC-0150LW2KR4 — Circuit Breaker Thermal Magnetic 2Pole 150A 480VAC
- BU2EHC-040LWKR2 — Circuit Breaker Thermal Magnetic 2Pole 40A 240VAC
More Circuit Breakers
- JLM-1-1RLS4-52-1-F1-225-S — Circuit Breaker Magnetic 1Pole 225A 65VDC
- APL111-1-62-503-AM — Hydraulic Magnetic 3-Pole 50A Toggle Switch, Panel Mount, -40 to 85°C
- 249-9-F-90-90-90-1-66-2 — Circuit Breaker Magnetic 9Pole
- 209-3-1-62-4-8-30 — Circuit Breaker Hydraulic Magnetic 3Pole 30A 240VAC
- 203-22-1-65-153-6-1-10 — Circuit Breaker Supplementary Protector 2Pole 15A 120VAC
- UPG1-1-62-302-00 — Hydraulic Magnetic Switch, 1-Pole, 3A, 2s-20s Trip Time, -40°C to 85°C
- APL11-1REC4-61-252-A — Hydraulic Magnetic 2-Pole Panel Mount Switch, 2.5A, 0.18-1.8s Trip Time
- JTEP-6-1REC4-53F-1-F1-1200 — Hydraulic Magnetic 6-Pole 65VDC 1200A Panel Mount Relay
BU3FHC-0100LW2KF2 FAQ
What is BU3FHC-0100LW2KF2?
BU3FHC-0100LW2KF2 is a Circuit Breaker from Fuji Electric. Circuit Breaker Thermal Magnetic 3Pole 100A 600VAC/250VDC.
Who manufactures BU3FHC-0100LW2KF2?
BU3FHC-0100LW2KF2 is manufactured by Fuji Electric.
What package and pinout does BU3FHC-0100LW2KF2 have?
BU3FHC-0100LW2KF2 comes in 6 pins, screw mount mounting.
What is the operating temperature range of BU3FHC-0100LW2KF2?
BU3FHC-0100LW2KF2 operates from -5 °C to 40 °C.
What are the equivalents or alternatives to BU3FHC-0100LW2KF2?
Parts with a similar function (Circuit Breaker) include BU3EHC-0100LW2KF6, BU3FHC-0100LW2KF6, BU3FHC-0100L1WKF6. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Fuji Electric
Ask AI Assistant
Ask questions about BU3FHC-0100LW2KF2 specifications
Click to ask a quick question:
Parameters
| AEC Qualified | No |
| Automotive | No |
| Cage Code | SCT92 |
| Current Rating | 100 |
| ECCN | EAR99 |
| HTS Code | 8536200040 |
| Max Operating Temperature | 40 |
| Min Operating Temperature | -5 |
| Mounting | Screw Mount |
| Number of Poles | 3 |
| Number of Terminals | 6 |
| PPAP | No |
| Radiation Hardening | No |
| RoHS Versions | 2002/95/EC |
| Schedule B | 8536300000 |
| Terminal Design | Lug |
| Type | Thermal Magnetic |
| Voltage Rating | 600VAC|250VDC |