86003 Datasheet

BeldenBulk Wire Cable

The Belden 86003 is an XTRAGUARD FLEX continuous flex data cable featuring 3 conductors of 28 AWG tinned copper with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for 300 V and temperatures up to 105°C, and is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems. It complies with AWM, CM, CMG, and FT4 flammability standards, offering sunlight and oil resistance for indoor and outdoor use.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

86003 Key Specifications

Nominal capacitance conductor-to-conductor
18 pF/ft (59 pF/m)
Nominal inductance
0.22 µH/ft (0.72 µH/m)
Voltage rating
300 V (UL AWM 2661, CMG, CM; CSA AWM)
Temperature range
Operating: -10°C to +105°C; Installation: +5°C to +105°C; UL Temperature: 105°C
Conductor configuration
3 conductors, 28 AWG, 7x36 stranded TC - Tinned Copper
Maximum pull tension
130 lbs (59 kg)
Minimum stationary bend radius
1.6 in (41 mm)
Nominal overall diameter
0.160 in (4.06 mm)

86003 Marking Code (SMD Code)

Top marking: LLXXXXXX CSA AWM I/II A/B FT4 105C 300V CE ROHS OIL RESISTANT (SEQ FOOTAGE) · package Slate PVC Outer Jacket (Reel, 100 ft or 500 ft)

Characteristics (datasheet)

Conductor configuration
3 conductors, 28 AWG, 7x36 stranded TC - Tinned Copper
Voltage rating
300 V (UL AWM 2661, CMG, CM; CSA AWM)
Temperature range
Operating: -10°C to +105°C; Installation: +5°C to +105°C; UL Temperature: 105°C
Nominal overall diameter
0.160 in (4.06 mm)
Nominal capacitance conductor-to-conductor
18 pF/ft (59 pF/m)
Nominal inductance
0.22 µH/ft (0.72 µH/m)
Minimum stationary bend radius
1.6 in (41 mm)
Maximum pull tension
130 lbs (59 kg)

86003 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking, serial communication, control panels, automation equipment, and instrumentation systems

Other Belden parts

  • 2400C — The Belden 2400C is a 2-conductor, 24 AWG tinned copper communication and contro...
  • 83562 — The Belden 83562 is a high-temperature, shielded multi-conductor cable featuring...
  • 70081 — The Belden 70081 is a discontinued 75 Ohm SDI coaxial cable of RG-59 type, desig...
  • 34430 — Belden 34430 is a low temp rubber lead wire with a 3/0 AWG (630x26) tinned coppe...
  • 74002 — The Belden 74002 is a shielded, 2-pair, 26 AWG stranded bare copper industrial E...
  • 7895A — The Belden 7895A is a DeviceBus® 2-pair communication cable featuring a tinned c...
  • 1304A — The 1304A is a CatSnake® Category 5E tactical cable featuring 4 bonded-pairs of...
  • 8749 — The Belden 8749 is a multi-pair electronic cable consisting of 15 pairs of 22 AW...

More Bulk Wire Cable

  • 2190A — The Belden 2190A is a discontinued composite outdoor cable designed for broadcas...
  • 21615 — Belden 21615 is a CSA Type TC-CIC 600 V tray cable with seventeen 10 AWG (7x18)...
  • 1761 — The Belden 1761 is a 3-conductor, 12 AWG tinned copper control and communication...
  • 50074LB — The Belden 50074LB is a 4-pair, 18 AWG stranded tinned copper RS-485 cable with...
  • 28126A — The Belden 28126A is a UL Type TC (1277) cable with 19 conductors of 12 AWG (7x2...
  • 8000 — The Belden 8000 is a 14 AWG (7x22) bare copper covered steel (BCCS) antenna wire...
  • 45080 — Belden 45080 is an XTRAGUARD 4 multi-conductor cable with 10 tinned copper 16 AW...
  • 1102 — The Belden 1102 is a communication and control cable consisting of four 32 AWG t...

86003 FAQ

What is 86003?

86003 is a Bulk Wire Cable from Belden. The Belden 86003 is an XTRAGUARD FLEX continuous flex data cable featuring 3 conductors of 28 AWG tinned copper with semi-rigid PVC insulation and a slate PVC outer jacket. It is rated for 300 V and temperatures up to 105°C, and is designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, automation, and instrumentation systems. It complies with AWM, CM, CMG, and FT4 flammability standards, offering sunlight and oil resistance for indoor and outdoor use.

Who manufactures 86003?

86003 is manufactured by Belden.

What is the marking code of 86003?

According to its datasheet, 86003 in Slate PVC Outer Jacket (Reel, 100 ft or 500 ft) is marked "LLXXXXXX CSA AWM I/II A/B FT4 105C 300V CE ROHS OIL RESISTANT (SEQ FOOTAGE)".

Where can I download the 86003 datasheet PDF?

The 86003 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 86003 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor configuration3 conductors, 28 AWG, 7x36 stranded TC - Tinned Copper
Maximum pull tension130 lbs (59 kg)
Minimum stationary bend radius1.6 in (41 mm)
Nominal capacitance conductor-to-conductor18 pF/ft (59 pF/m)
Nominal inductance0.22 µH/ft (0.72 µH/m)
Nominal overall diameter0.160 in (4.06 mm)
Temperature rangeOperating: -10°C to +105°C; Installation: +5°C to +105°C; UL Temperature: 105°C
Voltage rating300 V (UL AWM 2661, CMG, CM; CSA AWM)