AU-3C13UL Datasheet
Omega EngineeringCircuit Breakers
Thermal Magnetic 3-Pole 277/480VAC 13A DIN Rail Mount
No preview available
Download the PDF to view the complete datasheet
AU-3C13UL Key Specifications
- Current Rating
- 13
- Voltage Rating
- 277VAC|480VAC
- Max Operating Temperature
- 55 °C
- Min Operating Temperature
- -25 °C
- Actuator Type
- Handle
- Number of Poles
- 3
- Type
- Thermal Magnetic
AU-3C13UL Pinout & Package
- Number of Terminals
- 6
- Mounting
- DIN Rail
- Terminal Design
- Screw
AU-3C13UL Equivalents & Similar Components
Drop-in equivalents
Same package and key ratings at least as high.
Check pinout and ratings in both datasheets before substituting.
Other Omega Engineering parts
- AU-1C5DL — Circuit Breaker Thermal Magnetic 1Pole 5A 125VDC
- AU-1C10UL — Circuit Breaker Thermal Magnetic 1Pole 10A 277VAC/480VAC
- AU-3D03DL — Circuit Breaker Thermal Magnetic 2Pole 0.3A 250VDC
- AU-1D30UL — Circuit Breaker Thermal Magnetic 1Pole 30A 277VAC/480VAC
- AU-2D60DL — Circuit Breaker Thermal Magnetic 2Pole 60A 250VDC
- AU-3D20UL — Circuit Breaker Thermal Magnetic 3Pole 20A 277VAC/480VAC
- AU-1D8UL — Circuit Breaker Thermal Magnetic 1Pole 8A 277VAC/480VAC
- AU-3C60UL — Circuit Breaker Thermal Magnetic 3Pole 60A 240VAC
More Circuit Breakers
- BU3FHC-040Y1WKR2 — Circuit Breaker Thermal Magnetic 3Pole 40A 240VAC
- 209-1-1-64-4-8-3 — 240VAC Hydraulic Magnetic Relay, 3A, 0.1s to 1.5s Trip Time, Panel Mount
- 203-22-1-64F-153-6-1-8 — Supplementary Protector
- AP7-1-79-401 — Circuit Breaker Hydraulic Magnetic 1Pole 4A 240VAC
- 219-3-1-65-5-9-100-H — Circuit Breaker Magnetic 3Pole 100A 277VAC/480VAC
- BU3EHC-015Y1WKRJ — Circuit Breaker Thermal Magnetic 3Pole 15A 125VDC
- BU2EHC-0125Y1WKRM — Circuit Breaker Thermal Magnetic 2Pole 125A 24VDC
- 219-3-1-66-7-2-35 — Hydraulic Magnetic Circuit Breaker, 600VAC, 35A, 20s-200s Trip Time, Panel Mount
AU-3C13UL FAQ
What is AU-3C13UL?
AU-3C13UL is a Circuit Breakers from Omega Engineering. Thermal Magnetic 3-Pole 277/480VAC 13A DIN Rail Mount.
Who manufactures AU-3C13UL?
AU-3C13UL is manufactured by Omega Engineering.
What package and pinout does AU-3C13UL have?
AU-3C13UL comes in 6 pins, din rail mounting.
What is the operating temperature range of AU-3C13UL?
AU-3C13UL operates from -25 °C to 55 °C.
What are the equivalents or alternatives to AU-3C13UL?
Parts with a similar function (Circuit Breakers) include AU-3D13UL. Always compare pinout and electrical ratings in both datasheets before substituting.
Specifications
- Manufacturer
- Omega Engineering
Ask AI Assistant
Ask questions about AU-3C13UL specifications
Click to ask a quick question:
Parameters
| Actuator Type | Handle |
| Cage Code | 29907 |
| Current Rating | 13 |
| ECCN | EAR99 |
| EU RoHS | Yes |
| HTS Code | 8536200040 |
| Max Operating Temperature | 55 |
| Min Operating Temperature | -25 |
| Mounting | DIN Rail |
| Number of Poles | 3 |
| Number of Terminals | 6 |
| RoHS Versions | 2011/65/EU |
| Terminal Design | Screw |
| Type | Thermal Magnetic |
| Voltage Rating | 277VAC|480VAC |