9429 Datasheet
The Belden 9429 is a portable cordage with 20 conductors of 16 AWG bare copper, insulated with EPDM and jacketed with CPE, rated as UL Type SO. It is designed for extra hard service, oil-resistant applications, and for powering tools and appliances. The cable has a nominal diameter of 0.862 inches, a UL voltage rating of 600 V, and supports a maximum current of 6 Amps per conductor at 25°C within an operating temperature range of -20°C to +60°C.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
9429 Key Specifications
- Max. Current
- 6 Amps per Conductor at 25ºC
- UL Voltage Rating
- 600 V
- UL Temperature / Operating Temperature
- 60°C / -20°C To +60°C
- Bulk Cable Weight
- 445 lbs/1000ft
- Conductor configuration
- 20 Conductor 16AWG (65x34) Bare Copper
- Max. Pull Tension
- 650 lbs (290 kg)
- Min. Bend Radius (Stationary / Installation)
- 8.62 in (219 mm) / 8.62 in
- Nom. Conductor DCR
- 4.4 Ohm/1000ft
Characteristics (datasheet)
- Conductor configuration
- 20 Conductor 16AWG (65x34) Bare Copper
- Overall Cable Diameter (Nominal)
- 0.862 in
- UL Voltage Rating
- 600 V
- Max. Current
- 6 Amps per Conductor at 25ºC
- Nom. Conductor DCR
- 4.4 Ohm/1000ft
- UL Temperature / Operating Temperature
- 60°C / -20°C To +60°C
- Min. Bend Radius (Stationary / Installation)
- 8.62 in (219 mm) / 8.62 in
- Max. Pull Tension
- 650 lbs (290 kg)
- Bulk Cable Weight
- 445 lbs/1000ft
9429 Applications
- extra hard service cordage
- oil resistant applications
- to power tools and appliances
Other Belden parts
- 25122 — Belden part 25122 is an XTRAGUARD 2 cable consisting of 2 pairs of 22 AWG (7x30)...
- 4309FE — The Belden 4309FE is a security and commercial audio cable designed for security...
- 6084C — The 6084C is a 4-pair 24 AWG tinned copper shielded communication and control ca...
- 2125A — The Belden 2125A is a 600V TC-ER rated fieldbus cable featuring 24 pairs of 18AW...
- 6383 — The Belden 6383 is an 18-pair, 22 AWG stranded tinned copper communication and c...
- 29724C — Belden 29724C is a 3-conductor VFD power cable with 8 AWG bare copper XLPE-insul...
- 1313A — The Belden 1313A is a flexible, direct-burial speaker cable featuring two 10 AWG...
- 5224C — The Belden 5224C is an XTRAGUARD 1 multi-conductor cable featuring 19 conductors...
More Bulk Wire Cable
- 9877 — The Belden 9877 is a multi-pair audio, control, and instrument cable consisting...
- 83319E — The Belden 83319E is a high-temperature, flexible two-conductor electronic cable...
- 24519D — The Belden 24519D is a Canadian TC-ACIC 600 V instrumentation cable built with e...
- 9641 — The Belden 9641 is a computer EIA RS-488 cable featuring 26 AWG and 24 AWG stran...
- 5176C — The Belden 5176C is a 6-conductor, 16 AWG stranded tinned copper cable with PVC...
- 3233 — The Belden 3233 is a multi-conductor communication and control cable featuring 4...
- 77213 — The part 77213 is a 2-conductor 18 AWG tinned copper cable with mPPE insulation,...
- 8632MN — The 8632MN is a SpaceMaker™ 15-conductor 16 AWG tinned copper cable with polypro...
9429 FAQ
What is 9429?
9429 is a Bulk Wire Cable from Belden. The Belden 9429 is a portable cordage with 20 conductors of 16 AWG bare copper, insulated with EPDM and jacketed with CPE, rated as UL Type SO. It is designed for extra hard service, oil-resistant applications, and for powering tools and appliances. The cable has a nominal diameter of 0.862 inches, a UL voltage rating of 600 V, and supports a maximum current of 6 Amps per conductor at 25°C within an operating temperature range of -20°C to +60°C.
Who manufactures 9429?
9429 is manufactured by Belden.
Where can I download the 9429 datasheet PDF?
The 9429 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 9429 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 445 lbs/1000ft |
| Conductor configuration | 20 Conductor 16AWG (65x34) Bare Copper |
| Max. Current | 6 Amps per Conductor at 25ºC |
| Max. Pull Tension | 650 lbs (290 kg) |
| Min. Bend Radius (Stationary / Installation) | 8.62 in (219 mm) / 8.62 in |
| Nom. Conductor DCR | 4.4 Ohm/1000ft |
| Overall Cable Diameter (Nominal) | 0.862 in |
| UL Temperature / Operating Temperature | 60°C / -20°C To +60°C |
| UL Voltage Rating | 600 V |