The Belden 9155 is an audio and instrumentation cable consisting of one shielded pair of 20 AWG stranded tinned copper conductors and two unshielded 18 AWG stranded tinned copper conductors with polyethylene insulation and a CM PVC jacket. It is designed for indoor low voltage analog signals, low voltage digital control, line level audio, computer communication, and panel wiring.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
9155 Key Specifications
- Max. Current
- 7 Amps per Conductor at 25°C (20 AWG); 9 Amps per Conductor at 25°C (18 AWG)
- UL Voltage Rating
- 300 V (CM, UL AWM 2094)
- Operating Temperature
- -20°C to +60°C
- Bulk Cable Weight
- 45 lbs/1000ft
- Max. Pull Tension
- 70 lbs (32 kg)
- Nom. Characteristic Impedence (Pair)
- 66 Ohm
- Nom. Conductor DCR (Conductor)
- 6.6 Ohm/1000ft (22 Ohm/km)
- Nom. Conductor DCR (Pair)
- 10.5 Ohm/1000ft
Characteristics (datasheet)
- Overall Cable Diameter (Nominal)
- 0.262 in (6.65 mm)
- UL Voltage Rating
- 300 V (CM, UL AWM 2094)
- Operating Temperature
- -20°C to +60°C
- Max. Pull Tension
- 70 lbs (32 kg)
- Bulk Cable Weight
- 45 lbs/1000ft
- Nom. Conductor DCR (Pair)
- 10.5 Ohm/1000ft
- Nom. Conductor DCR (Conductor)
- 6.6 Ohm/1000ft (22 Ohm/km)
- Nom. Characteristic Impedence (Pair)
- 66 Ohm
- Max. Current
- 7 Amps per Conductor at 25°C (20 AWG); 9 Amps per Conductor at 25°C (18 AWG)
9155 Applications
- Low Voltage Analog Signals (4-20ma, 0-10v, ...)
- Low Voltage Digital Control (24v, …)
- Line Level Audio
- Computer Communication
- Panel Wiring
Other Belden parts
- 7987P — The Belden 7987P is a NanoSkew™ cable consisting of four 24 AWG solid bare coppe...
- 5423 — The Belden 5423 is a 3-conductor, 18 AWG tinned copper cable with PVC insulation...
- 972337002 — HIRSCHMANN TEST AND MEASUREMENT 972337002 TEST LEAD SET, BLK, RED, 1M, 1KV
- 6375 — The Belden 6375 is a communication and control cable featuring four pairs of 22...
- 8337 — The Belden 8337 is a computer EIA RS-232 cable featuring 7 pairs of 24 AWG stran...
- 1811A — The Belden 1811A is a discontinued speaker cable consisting of eight 14 AWG stra...
- 1299C — The Belden 1299C is a 9-conductor, 22 AWG tinned copper communication and contro...
- 6546PA — The Belden 6546PA is a plenum-rated cable designed for security, pro audio, and...
More Bulk Wire Cable
- 8621 — The Belden 8621 is a flexible multi-conductor cable consisting of seven 16 AWG s...
- 3553 — The Belden 3553 is a multi-conductor hook-up wire featuring 30 individual 26 AWG...
- 85240 — The Belden 85240 is a high-temperature, shielded triple-conductor cable built wi...
- 78122 — The Belden 78122 is a shielded multi-conductor cable (ECOCABLE) consisting of tw...
- 89841 — The Belden 89841 is a plenum-rated (CMP) RS-485 cable consisting of one pair of...
- 82241 — The Belden 82241 is a plenum-rated RG59 coaxial cable designed for analog video...
- 5172C — The Belden 5172C is a 2-conductor, 16 AWG tinned copper cable with PVC insulatio...
- 9311 — The Belden 9311 is an RG-58 type 50 Ohm wireless transmission coaxial cable feat...
9155 FAQ
What is 9155?
9155 is a Bulk Wire Cable from Belden. The Belden 9155 is an audio and instrumentation cable consisting of one shielded pair of 20 AWG stranded tinned copper conductors and two unshielded 18 AWG stranded tinned copper conductors with polyethylene insulation and a CM PVC jacket. It is designed for indoor low voltage analog signals, low voltage digital control, line level audio, computer communication, and panel wiring.
Who manufactures 9155?
9155 is manufactured by Belden.
Where can I download the 9155 datasheet PDF?
The 9155 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 9155 specifications
Click to ask a quick question:
Parameters
| Bulk Cable Weight | 45 lbs/1000ft |
| Max. Current | 7 Amps per Conductor at 25°C (20 AWG); 9 Amps per Conductor at 25°C (18 AWG) |
| Max. Pull Tension | 70 lbs (32 kg) |
| Nom. Characteristic Impedence (Pair) | 66 Ohm |
| Nom. Conductor DCR (Conductor) | 6.6 Ohm/1000ft (22 Ohm/km) |
| Nom. Conductor DCR (Pair) | 10.5 Ohm/1000ft |
| Operating Temperature | -20°C to +60°C |
| Overall Cable Diameter (Nominal) | 0.262 in (6.65 mm) |
| UL Voltage Rating | 300 V (CM, UL AWM 2094) |