89418 Datasheet

BeldenBulk Wire Cable

The Belden 89418 is a high-temperature, plenum-rated (CMP) electronic cable featuring four 18 AWG tinned copper conductors with FEP insulation, an overall Beldfoil shield, and an FEP outer jacket. It is designed for extreme high/low temperature environments, chemical resistance, outdoor and burial applications, and for transmitting low-voltage analog signals, low-voltage control, line-level audio, and voice communications.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

89418 Key Specifications

Max. current per conductor
13.6 Amps at 30°C
Nom. Capacitance Cond-to-Cond
30 pF/ft (98 pF/m)
Nom. Capacitance Cond-to-Shield
57 pF/ft (190 pF/m)
Nom. Inductance
0.15 µH/ft (0.49 µH/m)
UL Voltage Rating
300 V (CMP)
Operating temperature
-20°C to +150°C (UL temperature 150°C)
Bulk Cable Weight
36 lbs/1000ft
Conductor count
4

Characteristics (datasheet)

Conductor count
4
Conductor size
18 AWG (19x30 strand, TC - Tinned Copper)
Insulation material
FEP - Fluorinated Ethylene Propylene
Outer shield
Bi-Laminate (Alum+Poly) tape, 100% coverage, 20 AWG (19x32) TC drainwire
Outer jacket material
FEP - Fluorinated Ethylene Propylene
Nominal overall diameter
0.173 in (4.39 mm)
UL Voltage Rating
300 V (CMP)
Operating temperature
-20°C to +150°C (UL temperature 150°C)
Max. current per conductor
13.6 Amps at 30°C
Nom. Conductor DCR
7.06 Ohm/1000ft
Nom. Capacitance Cond-to-Cond
30 pF/ft (98 pF/m)
Nom. Capacitance Cond-to-Shield
57 pF/ft (190 pF/m)
Nom. Inductance
0.15 µH/ft (0.49 µH/m)
Nom. Velocity of Propagation
69%
Max. Pull Tension
114 lbs (51.7 kg)
Bulk Cable Weight
36 lbs/1000ft

89418 Applications

  • extreme high/low temperature environments
  • chemical resistant applications
  • outdoor and burial applications
  • low voltage analog signals (4-20ma, 0-10v)
  • low voltage control (24v)
  • line level audio
  • voice communications
  • panel wiring
  • indoor, outdoor, sunlight resistance, oil resistance, burial

Other Belden parts

  • 5686 — The Belden 5686 is a 7-conductor, 26 AWG tinned copper shielded cable with semi-...
  • 8240 — The Belden 8240 is a 50 Ohm RG-58 wireless transmission coaxial cable with a 20...
  • 78378 — The Belden 78378 is an ECOCABLE consisting of 8 pairs of 24 AWG tinned copper co...
  • 21655 — Belden 21655 is a CSA Type TC-CIC 600 V tray cable rated 90 °C dry and wet, with...
  • 26320FL — Belden 26320FL is an armored plenum-rated fire alarm cable (FPLP) with two 18 AW...
  • 9951 — The Belden 9951 is a single-conductor electronic cable featuring a 16 AWG tinned...
  • 9310 — The Belden 9310 is a 50 Ohm RG-58/U type coaxial cable featuring a 20 AWG solid...
  • 70051 — The Belden 70051 is a digital multi-modulation audio cable designed for use in p...

More Bulk Wire Cable

  • 65602 — The Belden 65602 is a flexible 2-conductor 16 AWG bare copper control cable with...
  • 1279 — The Belden 1279 is a communication and control cable featuring nine 14 AWG tinne...
  • 8219 — The Belden 8219 is an RG-58 type 50 Ohm wireless transmission coaxial cable feat...
  • 6194 — The Belden 6194 is a heavy-duty Teck90 600V cable designed with a 3+4+G bare cop...
  • 78405 — The Belden 78405 is an ECOCABLE featuring 20 conductors of 20 AWG tinned copper...
  • 45482 — Belden part 45482 is an XTRAGUARD 4 cable containing 2 pairs of 22 AWG (7x30) st...
  • 21590 — The Belden 21590 is a TC-CIC 600V Canadian instrumentation cable with 42 plus gr...
  • 80033 — The Belden 80033 is a 3-conductor, 18 AWG tinned copper control cable with mPPE...

89418 FAQ

What is 89418?

89418 is a Bulk Wire Cable from Belden. The Belden 89418 is a high-temperature, plenum-rated (CMP) electronic cable featuring four 18 AWG tinned copper conductors with FEP insulation, an overall Beldfoil shield, and an FEP outer jacket. It is designed for extreme high/low temperature environments, chemical resistance, outdoor and burial applications, and for transmitting low-voltage analog signals, low-voltage control, line-level audio, and voice communications.

Who manufactures 89418?

89418 is manufactured by Belden.

Where can I download the 89418 datasheet PDF?

The 89418 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 89418 specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight36 lbs/1000ft
Conductor count4
Conductor size18 AWG (19x30 strand, TC - Tinned Copper)
Insulation materialFEP - Fluorinated Ethylene Propylene
Max. current per conductor13.6 Amps at 30°C
Max. Pull Tension114 lbs (51.7 kg)
Nom. Capacitance Cond-to-Cond30 pF/ft (98 pF/m)
Nom. Capacitance Cond-to-Shield57 pF/ft (190 pF/m)
Nom. Conductor DCR7.06 Ohm/1000ft
Nominal overall diameter0.173 in (4.39 mm)
Nom. Inductance0.15 µH/ft (0.49 µH/m)
Nom. Velocity of Propagation69%
Operating temperature-20°C to +150°C (UL temperature 150°C)
Outer jacket materialFEP - Fluorinated Ethylene Propylene
Outer shieldBi-Laminate (Alum+Poly) tape, 100% coverage, 20 AWG (19x32) TC drainwire
UL Voltage Rating300 V (CMP)