86182CY Datasheet
The Belden 86182CY is a XTRAGUARD FLEX two-conductor 18 AWG tinned copper cable designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, and automation equipment. It features semi-rigid PVC insulation, an overall aluminum/polyester and tinned copper spiral shield, and a slate PVC outer jacket rated for 300 V and temperatures from -10°C to +105°C. The cable offers sunlight resistance, a minimum stationary bend radius of 2.3 inches, and complies with AWM, CM, CMG, and PLTC standards for indoor and outdoor use.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
86182CY Key Specifications
- Nominal Capacitance Cond-to-Cond
- 49 pF/ft (160 pF/m)
- Voltage Rating
- 300 V (AWM 2661, CMG, CM / CSA AWM)
- Operating Temperature
- -10°C to +105°C (UL 105°C)
- Characteristic Impedance
- 38 Ohm
- Conductor Configuration
- 2-conductor 18 AWG (41x34) tinned copper (TC)
- Mechanical limits
- Max pull tension: 75 lbs (34 kg); Min stationary bend radius: 2.3 in (58 mm)
- Nominal Overall Diameter
- 0.230 in (5.84 mm)
- Shielding
- 100% Alum/Poly tape + 90% tinned copper spiral serve with 26 AWG drain wire
Characteristics (datasheet)
- Voltage Rating
- 300 V (AWM 2661, CMG, CM / CSA AWM)
- Conductor Configuration
- 2-conductor 18 AWG (41x34) tinned copper (TC)
- Operating Temperature
- -10°C to +105°C (UL 105°C)
- Nominal Overall Diameter
- 0.230 in (5.84 mm)
- Characteristic Impedance
- 38 Ohm
- Nominal Capacitance Cond-to-Cond
- 49 pF/ft (160 pF/m)
- Shielding
- 100% Alum/Poly tape + 90% tinned copper spiral serve with 26 AWG drain wire
- Mechanical limits
- Max pull tension: 75 lbs (34 kg); Min stationary bend radius: 2.3 in (58 mm)
86182CY Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 9773 — The Belden 9773 is an audio, control, and instrument cable featuring three indiv...
- 65267CY — The Belden 65267CY is an XTRAGUARD FLEX flexible control cable featuring 7 condu...
- 4643FDW — The Belden 4643FDW is an OSDP RS-485 instrumentation and computer cable designed...
- 8690 — The Belden 8690 is a 3-pair 18 AWG tinned copper cable with PVC insulation and a...
- 78222 — The Belden 78222 is a 2-pair 24 AWG stranded tinned copper ECOCABLE with modifie...
- 89913 — The Belden 89913 is a 50 Ohm wireless transmission RG-8 coaxial cable with a 10...
- 7785A — The Belden 7785A is a discontinued triaxial cable designed for analog video appl...
- 8489 — The Belden 8489 is a 4-conductor, 18 AWG tinned copper electronic cable with PVC...
More Bulk Wire Cable
- 65809 — The Belden 65809 is a 9-conductor 18 AWG bare copper XTRAGUARD FLEX control cabl...
- 23505D — The Belden 23505D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, bui...
- 30802 — Belden 30802 is a 2 AWG rubber lead wire with 163x24 stranded tinned copper cond...
- 2256 — The Belden 2256 is a communication and control cable featuring two 20 AWG tinned...
- 8692 — The Belden 8692 is a multi-conductor cable featuring 9 pairs of 18 AWG tinned co...
- 6408 — The Belden 6408 is a communication and control cable featuring 10 pairs of 24 AW...
- 3124A — The Belden 3124A is a DeviceBus® multipair cable designed for Square D/Seriplex®...
- 1347A — The Belden 1347A is a composite cable designed for electronic news gathering (EN...
86182CY FAQ
What is 86182CY?
86182CY is a Bulk Wire Cable from Belden. The Belden 86182CY is a XTRAGUARD FLEX two-conductor 18 AWG tinned copper cable designed for data, communication, audio, and low-level signal transmission in industrial networking, control panels, and automation equipment. It features semi-rigid PVC insulation, an overall aluminum/polyester and tinned copper spiral shield, and a slate PVC outer jacket rated for 300 V and temperatures from -10°C to +105°C. The cable offers sunlight resistance, a minimum stationary bend radius of 2.3 inches, and complies with AWM, CM, CMG, and PLTC standards for indoor and outdoor use.
Who manufactures 86182CY?
86182CY is manufactured by Belden.
Where can I download the 86182CY datasheet PDF?
The 86182CY datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 86182CY specifications
Click to ask a quick question:
Parameters
| Characteristic Impedance | 38 Ohm |
| Conductor Configuration | 2-conductor 18 AWG (41x34) tinned copper (TC) |
| Mechanical limits | Max pull tension: 75 lbs (34 kg); Min stationary bend radius: 2.3 in (58 mm) |
| Nominal Capacitance Cond-to-Cond | 49 pF/ft (160 pF/m) |
| Nominal Overall Diameter | 0.230 in (5.84 mm) |
| Operating Temperature | -10°C to +105°C (UL 105°C) |
| Shielding | 100% Alum/Poly tape + 90% tinned copper spiral serve with 26 AWG drain wire |
| Voltage Rating | 300 V (AWM 2661, CMG, CM / CSA AWM) |