80034 Datasheet
The Belden 80034 is a 4-conductor, 18 AWG tinned copper cable with mPPE insulation and a slate-colored, halogen-free polyurethane (PUR) outer jacket. It is rated for 600 V and a UL temperature of 105°C, offering resistance to oil, sunlight, and flame. This cable is suitable for data, communication, audio, low-level signal transmission, industrial networking, and automation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
80034 Key Specifications
- Nominal Capacitance (Cond-to-Cond)
- 20.5 pF/ft (67.3 pF/m)
- Nominal Inductance
- 0.17 µH/ft (0.56 µH/m)
- Voltage Rating
- 600 V (UL AWM 11231, AWM 21959 / CSA AWM)
- UL Temperature Rating
- 105°C (Operating: -50°C to +90°C; Installation: -40°C to +80°C)
- Conductor
- 4 x 18 AWG stranded TC (Tinned Copper), 41x34 stranding
- Max Pull Tension
- 26 lbs (12 kg)
- Min. Stationary Bend Radius
- 2.3 in (58 mm)
- Nominal Overall Diameter
- 0.231 in (5.87 mm)
Characteristics (datasheet)
- Conductor
- 4 x 18 AWG stranded TC (Tinned Copper), 41x34 stranding
- Voltage Rating
- 600 V (UL AWM 11231, AWM 21959 / CSA AWM)
- UL Temperature Rating
- 105°C (Operating: -50°C to +90°C; Installation: -40°C to +80°C)
- Nominal Overall Diameter
- 0.231 in (5.87 mm)
- Nominal Capacitance (Cond-to-Cond)
- 20.5 pF/ft (67.3 pF/m)
- Nominal Inductance
- 0.17 µH/ft (0.56 µH/m)
- Max Pull Tension
- 26 lbs (12 kg)
- Min. Stationary Bend Radius
- 2.3 in (58 mm)
80034 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 45463 — Belden part 45463 is an XTRAGUARD 4 multi-conductor cable with 3 conductors of 2...
- 83351E — The Belden 83351E is a high-temperature, 4-conductor 18 AWG silver-plated copper...
- 70251PU — The Belden 70251PU is a PUR sensor and actuator cable with 4 conductors (copper...
- 21627 — The Belden 21627 is a CSA Tray Cable (TC-CIC) rated 600 V containing 29 conducto...
- 50094LS — The Belden 50094LS is an RS-485 cable consisting of 4 pairs of 22 AWG stranded t...
- 65418 — The Belden 65418 is an XTRAGUARD FLEX 18-conductor 14 AWG bare copper control ca...
- 77055 — The Belden 77055 is a 6-conductor, 28 AWG stranded tinned copper ECOCABLE with M...
- 78453 — The Belden 78453 is a 25-conductor, 24 AWG tinned copper cable with modified pol...
More Bulk Wire Cable
- 29547 — Belden 29547 is a flexible VFD motor supply cable with three 4/0 AWG tinned copp...
- 78064 — The Belden 78064 is an ECOCABLE multi-conductor cable with 4 pairs of 26 AWG tin...
- 23524D — Belden 23524D is a Canadian TC-ACIC 300V instrumentation cable with 12 pairs of...
- 6416 — The Belden 6416 is a communication and control cable consisting of two pairs of...
- 45451 — Belden part 45451 is an XTRAGUARD 4 single-pair cable with 20 AWG stranded tinne...
- 45483 — The Belden 45483 is an XTRAGUARD 4 cable with 3 pairs of 22 AWG (7x30) stranded...
- 58431 — The Belden 58431 is a plenum-rated, shielded 2-conductor 18 AWG bare copper cabl...
- 83950 — The Belden 83950 is a Type JX thermocouple cable designed for industrial control...
80034 FAQ
What is 80034?
80034 is a Bulk Wire Cable from Belden. The Belden 80034 is a 4-conductor, 18 AWG tinned copper cable with mPPE insulation and a slate-colored, halogen-free polyurethane (PUR) outer jacket. It is rated for 600 V and a UL temperature of 105°C, offering resistance to oil, sunlight, and flame. This cable is suitable for data, communication, audio, low-level signal transmission, industrial networking, and automation systems.
Who manufactures 80034?
80034 is manufactured by Belden.
Where can I download the 80034 datasheet PDF?
The 80034 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 80034 specifications
Click to ask a quick question:
Parameters
| Conductor | 4 x 18 AWG stranded TC (Tinned Copper), 41x34 stranding |
| Max Pull Tension | 26 lbs (12 kg) |
| Min. Stationary Bend Radius | 2.3 in (58 mm) |
| Nominal Capacitance (Cond-to-Cond) | 20.5 pF/ft (67.3 pF/m) |
| Nominal Inductance | 0.17 µH/ft (0.56 µH/m) |
| Nominal Overall Diameter | 0.231 in (5.87 mm) |
| UL Temperature Rating | 105°C (Operating: -50°C to +90°C; Installation: -40°C to +80°C) |
| Voltage Rating | 600 V (UL AWM 11231, AWM 21959 / CSA AWM) |