80007 Datasheet

BeldenBulk Wire Cable

The Belden 80007 is a 9-conductor, 26 AWG tinned copper control cable with mPPE insulation and a zero halogen slate polyurethane outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V, offers oil and sunlight resistance, and operates within a temperature range of -50°C to +90°C.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

80007 Key Specifications

Nom. Capacitance Cond-to-Cond
17 pF/ft (56 pF/m)
Nom. Inductance
0.2 µH/ft (0.66 µH/m)
Voltage rating
600 V (AWM 11231, AWM 21959) / 600 V (CSA AWM)
Temperature range
Operating: -50°C To +90°C; Installation: -40°C To +80°C; UL Temperature: 105°C
Conductor count
9
Conductor size / stranding
26 AWG 19x38 TC - Tinned Copper
Min. bend radius (stationary)
2.3 in (58 mm)
Overall cable diameter (nominal)
0.235 in (5.97 mm)

Characteristics (datasheet)

Conductor count
9
Conductor size / stranding
26 AWG 19x38 TC - Tinned Copper
Voltage rating
600 V (AWM 11231, AWM 21959) / 600 V (CSA AWM)
Nom. Capacitance Cond-to-Cond
17 pF/ft (56 pF/m)
Nom. Inductance
0.2 µH/ft (0.66 µH/m)
Temperature range
Operating: -50°C To +90°C; Installation: -40°C To +80°C; UL Temperature: 105°C
Overall cable diameter (nominal)
0.235 in (5.97 mm)
Min. bend radius (stationary)
2.3 in (58 mm)

80007 Applications

  • Data, communication, audio, and low-level signal transmission
  • Industrial networking
  • Serial communication
  • Control panels
  • Automation equipment
  • Instrumentation systems

Other Belden parts

  • 80146 — The Belden 80146 is a zero-halogen, 9-conductor 16 AWG stranded tinned copper ca...
  • 80162 — The Belden 80162 is a 9-conductor, 12 AWG tinned copper multi-conductor cable fe...
  • 78014 — The 78014 is a 4-conductor 26 AWG tinned copper cable with modified polyphenylen...
  • 65007 — The part 65007 is an XTRAGUARD FLEX flexible control cable consisting of 7 condu...
  • 4506FE — The Belden 4506FE is an 8-conductor 22 AWG stranded bare copper cable designed f...
  • 74043E — The Belden 74043E is an industrial-grade DataTuff Single Pair Ethernet (SPE) cab...
  • 9271 — The Belden 9271 is a 124 Ohm twinaxial cable designed with 25 AWG stranded tinne...
  • 80127 — The Belden 80127 (Alpha Wire P/N 80127) is an 18-conductor, 20 AWG tinned copper...

More Bulk Wire Cable

  • 70051 — The Belden 70051 is a digital multi-modulation audio cable designed for use in p...
  • 5406UE — The Belden 5406UE is a security & sound riser-CMR cable consisting of 8 stranded...
  • 1069 — The Belden 1069 is a 9-conductor, 16 AWG stranded tinned copper communication an...
  • 4640FDW — The 4640FDW is an active, low smoke zero halogen (LSZH) jacketed cable designed...
  • 8877MN — The 8877MN is a SpaceMaker™ 7-conductor 20 AWG tinned copper cable with polyprop...
  • 78166 — The part 78166 is a 6-pair 26 AWG tinned copper ECOCABLE with modified polypheny...
  • 4794P — The Belden 4794P is a Series 7, 75 Ohm SDI coaxial cable featuring a 16 AWG soli...
  • 7438W — The Belden 7438W is a high-flex, 7-conductor (6 power plus 1 ground) 14 AWG bare...

80007 FAQ

What is 80007?

80007 is a Bulk Wire Cable from Belden. The Belden 80007 is a 9-conductor, 26 AWG tinned copper control cable with mPPE insulation and a zero halogen slate polyurethane outer jacket. It is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems. The cable is rated for 600 V, offers oil and sunlight resistance, and operates within a temperature range of -50°C to +90°C.

Who manufactures 80007?

80007 is manufactured by Belden.

Where can I download the 80007 datasheet PDF?

The 80007 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 80007 specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor count9
Conductor size / stranding26 AWG 19x38 TC - Tinned Copper
Min. bend radius (stationary)2.3 in (58 mm)
Nom. Capacitance Cond-to-Cond17 pF/ft (56 pF/m)
Nom. Inductance0.2 µH/ft (0.66 µH/m)
Overall cable diameter (nominal)0.235 in (5.97 mm)
Temperature rangeOperating: -50°C To +90°C; Installation: -40°C To +80°C; UL Temperature: 105°C
Voltage rating600 V (AWM 11231, AWM 21959) / 600 V (CSA AWM)