72-10495 Datasheet
Bench Power Supply 0V to 30V Single-OUT 5A
The part 72-10495 is a bench power supply unit with a dual output, providing a voltage range of 0 to 30V and a current range of 0 to 5A. It features complete digital control with constant voltage (CV) and constant current (CC) modes, along with low noise and ripple. It is designed for indoor laboratory bench use, offering high-resolution setting and read-back of voltage and current parameters.
72-10495 Key Specifications
- Current Range
- 0 to 5A x 2
- Line Regulation (Current)
- 0.01% +3mA
- Line Regulation (Voltage)
- 0.01% +3mV
- Load Regulation (Current)
- 0.02% +5mA
- Load Regulation (Voltage)
- 0.01% +4mV
- Max Output Current
- 5A / 30 V
- Max Output Voltage
- 30V
- Max Supply Voltage
- 253V
72-10495 Marking Code (SMD Code)
Top marking: 72-10495
Characteristics (datasheet)
- Voltage Range
- 0 to 30V
- Current Range
- 0 to 5A × 2
- Setup Resolution
- Voltage : 10mV, Current : 1mA
- Setup Accuracy (25°C ±5°C)
- Voltage : ≤ 0.5% +20mV, Current : ≤ 0.5% +15mA
- Ripple (20Hz to 20MHz)
- Voltage : ≤ 1.5mVrms, Current : ≤ 3mArms
- Load Regulation
- Voltage : ≤ 0.01% +4mV, Current : ≤ 0.02% +5mA
- Line Regulation
- Voltage : ≤ 0.01% +3mV, Current : ≤ 0.01% +3mA
- Weight and Dimensions
- 9 kg, 220(W) × 280(H) × 160(D)
Other Tenma parts
- 72-8380 — 200MHz 100V 240V 1MR 500MS/s Digital Oscilloscope
- 72-7295 — POWER SUPPLY, BENCH, 40V, 200W; Power Supply Output Type:Adjustable; No. of Outp...
- 72-8705 — TENMA 72-8705 Oscilloscope, 2 Analogue, 50 MHz, 1 GSPS, 600 kpts, 7 ns
- 72-7712 — TENMA 72-7712 THERMOMETER, 2CH
- 72-7690 — POWER SUPPLY, BENCH, 18V; Power Supply Output Type:Adjustable; No. of Outputs:1;...
- 72-7750 — TENMA 72-7750 MULTIMETER, DIG, HAND HELD, 3.75 DIGITS
- 72-7730 — MULTIMETER, DIG HAND HELD, 20000
- 72-10175 — TENMA 72-10175 OSCILLOSCOPE
More Test Equipment
- 380360 — Insulation Testers / Megohmmeters Digital Megohmmeter
- N8739A — Laboratory power supply 3.3 kW 100 VDC @ 50 mV, N8739A, Keysight
- U1732P — LCR Meter Kit, U1732P, Keysight
- TKPZ-LV2 — LED Stereo Microscope 5X-65X, Base Mount
- FQM-KIT — FLUKE NETWORKS FQM-KIT KIT, TESTER, FIBER, QUICKMAP
- 382068 — Clamp Multimeters u0026 Accessories POWER DATALOGGER KIT 1000A TRMS AC/DC
- 510900 — Test Accessories - Other 10-30 kV Pole Phase Comparator
- N2916B — Rackmount kit for 5000 and 6000 Series oscilloscopes
72-10495 FAQ
What is 72-10495?
72-10495 is a Test Equipment from Tenma. Bench Power Supply 0V to 30V Single-OUT 5A.
Who manufactures 72-10495?
72-10495 is manufactured by Tenma.
What is the marking code of 72-10495?
According to its datasheet, 72-10495 is marked "72-10495".
Where can I download the 72-10495 datasheet PDF?
The 72-10495 datasheet PDF (206 KB) can be downloaded free from this page using the Download PDF button.
Specifications
- Manufacturer
- Tenma
- Category
- Test MeasurementTest Equipment
- File Size
- 206 KB
Ask AI Assistant
Ask questions about 72-10495 specifications
Click to ask a quick question:
Parameters
| Accessories | User manual, UK Power cord (1.2m), Euro Power cord (1.2m) |
| Current Range | 0 to 5A x 2 |
| Dimension (W x H x D) | 220 x 280 x 160 |
| Line Regulation (Current) | 0.01% +3mA |
| Line Regulation (Voltage) | 0.01% +3mV |
| Load Regulation (Current) | 0.02% +5mA |
| Load Regulation (Voltage) | 0.01% +4mV |
| Max Output Current | 5A / 30 V |
| Max Output Voltage | 30V |
| Max Supply Voltage | 253V |
| Min Output Voltage | 0V |
| Min Supply Voltage | 207V |
| Number of Outputs | 2 |
| Operation Environment (Altitude) | 2000 |
| Operation Environment (Ambient Temperature) | 0°C to +40°C |
| Operation Environment (Relative Humidity) | 80 |
| Operation Environment (Usage) | Indoor use |
| Reaction Time (10% Rated load) (Voltage Drop) | 100 |
| Reaction Time (10% Rated load) (Voltage Rise) | 100 |
| Read Back Accuracy (Current) | 1 |
| Read Back Accuracy (Voltage) | 10 |
| Read Back Temp. Coefficient (Current) | 100ppm +5mA |
| Read Back Temp. Coefficient (Voltage) | 100ppm +10mV |
| Ripple (20Hz to 20MHz) (Current) | 3 |
| Ripple (20Hz to 20MHz) (Voltage) | 1.5 |
| RoHS | Compliant |
| Setup Accuracy (25°C ±5°C) (Current) | 0.5% +15mA |
| Setup Accuracy (25°C ±5°C) (Voltage) | 0.5% +20mV |
| Setup Resolution (Current) | 1 |
| Setup Resolution (Voltage) | 10 |
| Storage Environment (Ambient Temperature) | -10°C to +70°C |
| Storage Environment (Relative Humidity) | 70 |
| Temp. Coefficient (Current) | 0.1% +5mA |
| Temp. Coefficient (Voltage) | 0.1% +10mV |
| Voltage Range | 0 to 30 |
| Weight | 9 |