6396 Datasheet
The Belden 6396 is a 12-pair 28 AWG tinned copper communication and control cable featuring polyethylene insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V (CM) / 150 V (CL2) and operates within a temperature range of -20°C to +75°C. This cable is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
6396 Key Specifications
- UL Voltage Rating
- 300 V (CM), 150 V (CL2)
- Operating Temperature
- -20°C To +75°C
- Characteristic Impedance
- 100 Ohm
- Conductor
- 12 Pair 28 AWG (7x36) TC - Tinned Copper
- Insulation
- Polyethylene (PE), Nom. Thickness 0.010 in (0.25 mm)
- Max. Pull Tension
- 24.2 lbs (11.0 kg)
- Min. Bend Radius (Stationary)
- 3.4 in (86 mm)
- Nominal Overall Diameter
- 0.335 in (8.51 mm)
6396 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 6396 12PR 28 AWG SHIELDED 75C (UL) TYPE CL2 OR AWM 2960 C(UL) TYPE CM 60C FT1 CE ROHS
Characteristics (datasheet)
- Conductor
- 12 Pair 28 AWG (7x36) TC - Tinned Copper
- Insulation
- Polyethylene (PE), Nom. Thickness 0.010 in (0.25 mm)
- Outer Shield
- Tape Bi-Laminate (Alum+Poly) 100% coverage; Braid Tinned Copper (TC) 90% coverage
- Outer Jacket
- Slate PVC - Polyvinyl Chloride, Nom. Thickness 0.035 in (0.89 mm)
- Nominal Overall Diameter
- 0.335 in (8.51 mm)
- UL Voltage Rating
- 300 V (CM), 150 V (CL2)
- Operating Temperature
- -20°C To +75°C
- Characteristic Impedance
- 100 Ohm
- Min. Bend Radius (Stationary)
- 3.4 in (86 mm)
- Max. Pull Tension
- 24.2 lbs (11.0 kg)
6396 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 8448 — The Belden 8448 is an 8-conductor electronic cable featuring two 18 AWG and six...
- 76207WS — The Belden 76207WS is a MachFlex™ high-flex cable designed for applications requ...
- 80040 — The Belden 80040 (P/N 80040) is a zero-halogen, 25-conductor, 18 AWG tinned copp...
- 30812 — The Belden 30812 is a 12 AWG stranded tinned copper lead wire with silicone rubb...
- 5108C — The Belden 5108C is an XTRAGUARD 1 multi-conductor shielded cable featuring eigh...
- 1035A — The Belden 1035A is a UL-listed instrumentation cable containing one pair of 16...
- 79227 — The Belden 79227 is a 4-conductor 14 AWG tinned copper cable with mPPE insulatio...
- 9954 — The Belden 9954 is a shielded 4-conductor cable featuring 16 AWG stranded tinned...
More Bulk Wire Cable
- 1861A — The Belden 1861A is a plenum-rated (CL2P) unshielded speaker cable designed for...
- 5425 — The Belden 5425 is a multi-conductor, 18 AWG tinned copper cable with PVC insula...
- 83264 — The Belden 83264 is a commercial, non-QPL Mil-Spec coaxial cable (RG-179 type) w...
- 7026 — The Belden 7026 is a single-conductor hook-up wire featuring an 18 AWG tinned co...
- 9932 — The Belden 9932 is a computer EIA RS-232/423 cable featuring 24 AWG stranded tin...
- 9761MN — The Belden 9761MN is a SpaceMaker™ multi-pair cable featuring four 16 AWG tinned...
- 3233 — The Belden 3233 is a multi-conductor communication and control cable featuring 4...
- 5351C — The Belden 5351C is a 7-pair, 20 AWG tinned copper conductor shielded cable with...
6396 FAQ
What is 6396?
6396 is a Bulk Wire Cable from Belden. The Belden 6396 is a 12-pair 28 AWG tinned copper communication and control cable featuring polyethylene insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V (CM) / 150 V (CL2) and operates within a temperature range of -20°C to +75°C. This cable is designed for data, communication, audio, and low-level signal transmission, as well as use in industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Who manufactures 6396?
6396 is manufactured by Belden.
What is the marking code of 6396?
According to its datasheet, 6396 is marked "Alpha Wire -* P/N 6396 12PR 28 AWG SHIELDED 75C (UL) TYPE CL2 OR AWM 2960 C(UL) TYPE CM 60C FT1 CE ROHS".
Where can I download the 6396 datasheet PDF?
The 6396 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 6396 specifications
Click to ask a quick question:
Parameters
| Characteristic Impedance | 100 Ohm |
| Conductor | 12 Pair 28 AWG (7x36) TC - Tinned Copper |
| Insulation | Polyethylene (PE), Nom. Thickness 0.010 in (0.25 mm) |
| Max. Pull Tension | 24.2 lbs (11.0 kg) |
| Min. Bend Radius (Stationary) | 3.4 in (86 mm) |
| Nominal Overall Diameter | 0.335 in (8.51 mm) |
| Operating Temperature | -20°C To +75°C |
| Outer Jacket | Slate PVC - Polyvinyl Chloride, Nom. Thickness 0.035 in (0.89 mm) |
| Outer Shield | Tape Bi-Laminate (Alum+Poly) 100% coverage; Braid Tinned Copper (TC) 90% coverage |
| UL Voltage Rating | 300 V (CM), 150 V (CL2) |