6064 Datasheet

BeldenBulk Wire Cable

The Belden 6064 is a heavy-duty Teck90 600V cable featuring 50 bare copper conductors plus a ground wire, with XLPE insulation, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. It is rated for harsh environments with an operating temperature range of -40°C to +90°C, offering sun and UV resistance. This cable is designed specifically for CEC power and control applications in indoor and outdoor environments.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

6064 Key Specifications

Max. Current
12.5 Amps per Conductor at 30°C (Conductors), 25 Amps per Conductor at 30°C (Ground Wire)
Voltage Rating
600 V (TECK 90)
Operating Temperature
-40°C To +90°C (UL Temperature 90°C)
Bulk Cable Weight
1471 lbs/1000ft
Conductors
50 x 14 AWG Bare Copper (7x22) + 1 x 14 AWG Bare Copper Ground Wire
Max. Pull Tension / Bend Radius
2984.6 lbs (1353.8 kg) / Min. Bend Radius 13.136 in (333.65 mm)
Nom. Conductor DCR
2.65 Ohm/1000ft (Conductors), 2.67 Ohm/1000ft (Ground Wire)
Nominal Overall Diameter
1.642 in (41.71 mm)

Characteristics (datasheet)

Voltage Rating
600 V (TECK 90)
Conductors
50 x 14 AWG Bare Copper (7x22) + 1 x 14 AWG Bare Copper Ground Wire
Nom. Conductor DCR
2.65 Ohm/1000ft (Conductors), 2.67 Ohm/1000ft (Ground Wire)
Max. Current
12.5 Amps per Conductor at 30°C (Conductors), 25 Amps per Conductor at 30°C (Ground Wire)
Operating Temperature
-40°C To +90°C (UL Temperature 90°C)
Nominal Overall Diameter
1.642 in (41.71 mm)
Bulk Cable Weight
1471 lbs/1000ft
Max. Pull Tension / Bend Radius
2984.6 lbs (1353.8 kg) / Min. Bend Radius 13.136 in (333.65 mm)

6064 Applications

  • CEC Power and Control Applications

Other Belden parts

  • 3210 — The Belden 3210 is a single-conductor communication and control cable featuring...
  • 29527 — Belden 29527 is a premium VFD power cable with three 2 AWG tinned copper conduct...
  • 25506D — Belden 25506D is a Canadian TC-ACIC 600 V instrumentation cable built with one 1...
  • 7835ANH — The Belden 7835ANH is a Category 6 premise horizontal cable featuring four pairs...
  • 2461C — The Belden 2461C is a shielded, 2-conductor 22 AWG tinned copper communication a...
  • 78216 — The Belden 78216 (Alpha Wire P/N 78216) is a multi-pair cable featuring 6 pairs...
  • 77002 — The Belden 77002 is a 4-conductor, 24 AWG tinned copper cable with mPPE insulati...
  • 9717 — The Belden 9717 is a discontinued, unshielded speaker cable featuring two parall...

More Bulk Wire Cable

  • 6224C — The Belden 6224C is a shielded low-voltage communication and control cable consi...
  • 3074F — The 3074F is a 120Ω RS-485 twinaxial cable featuring one pair of 18 AWG tinned c...
  • 39114 — Belden part 39114 is a 14 AWG low-temperature plastic lead wire with 41x30 stran...
  • 29722C — The Belden 29722C is a 3-conductor VFD power cable built with 12 AWG (7x20) bare...
  • 76510TS — The Belden 76510TS is a MachFlex™ high-flex cable designed with 10 pairs of 26 A...
  • 58414 — The Belden 58414 is a plenum-rated, overall shielded communication and control c...
  • 38010 — The Belden 38010 is a UL Type PV wire with 10 AWG tinned copper conductors (105x...
  • 7417W — The Belden 7417W is a MachFlex™ high-flex cable designed for use in robotics and...

6064 FAQ

What is 6064?

6064 is a Bulk Wire Cable from Belden. The Belden 6064 is a heavy-duty Teck90 600V cable featuring 50 bare copper conductors plus a ground wire, with XLPE insulation, a PVC inner jacket, aluminum interlock armor, and a black PVC outer jacket. It is rated for harsh environments with an operating temperature range of -40°C to +90°C, offering sun and UV resistance. This cable is designed specifically for CEC power and control applications in indoor and outdoor environments.

Who manufactures 6064?

6064 is manufactured by Belden.

Where can I download the 6064 datasheet PDF?

The 6064 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 6064 specifications

AI Powered

Click to ask a quick question:

Parameters

Bulk Cable Weight1471 lbs/1000ft
Conductors50 x 14 AWG Bare Copper (7x22) + 1 x 14 AWG Bare Copper Ground Wire
Max. Current12.5 Amps per Conductor at 30°C (Conductors), 25 Amps per Conductor at 30°C (Ground Wire)
Max. Pull Tension / Bend Radius2984.6 lbs (1353.8 kg) / Min. Bend Radius 13.136 in (333.65 mm)
Nom. Conductor DCR2.65 Ohm/1000ft (Conductors), 2.67 Ohm/1000ft (Ground Wire)
Nominal Overall Diameter1.642 in (41.71 mm)
Operating Temperature-40°C To +90°C (UL Temperature 90°C)
Voltage Rating600 V (TECK 90)