58809 Datasheet
The Belden 58809 is a communication and control cable consisting of 9 pairs of 24 AWG tinned copper conductors with FEP insulation, an overall aluminum/polyester shield, and a slate PVDF outer jacket. It is rated for a UL voltage of 300 V (CMP) and a maximum operating temperature of 125°C, with an operating range of -25°C to +125°C. The cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
58809 Key Specifications
- Nominal Capacitance Cond-to-Cond
- 18 pF/ft (59 pF/m)
- UL Voltage Rating
- 300 V (CMP)
- Operating Temperature
- -25°C to +125°C (UL Temperature: 125°C)
- Conductor
- 9 pair, 24 AWG 7x32 TC - Tinned Copper
- Insulation
- FEP - Fluorinated Ethylene Propylene, nominal thickness 0.007 in (0.18 mm)
- Max. Pull Tension / Min. Bend Radius
- 9.5 lbs (4.3 kg) max pull tension, 2.6 in (66 mm) min. stationary bend radius
- Nominal Characteristic Impedance
- 84 Ohm
- Nominal Overall Diameter
- 0.256 in (6.50 mm)
58809 Marking Code (SMD Code)
Top marking: Alpha Wire -* P/N 58809 9PR 24 AWG SHIELDED 125C (UL) TYPE CMP OR C(UL) TYPE CMP FT6 CE ROHS · package Cable (Reel, 500 ft or 1,000 ft)
Characteristics (datasheet)
- Conductor
- 9 pair, 24 AWG 7x32 TC - Tinned Copper
- Insulation
- FEP - Fluorinated Ethylene Propylene, nominal thickness 0.007 in (0.18 mm)
- Outer Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, with 24 AWG (7x32) TC drainwire
- Outer Jacket
- PVDF - Polyvinylidene Fluoride, nominal thickness 0.011 in (0.28 mm)
- Nominal Overall Diameter
- 0.256 in (6.50 mm)
- UL Voltage Rating
- 300 V (CMP)
- Operating Temperature
- -25°C to +125°C (UL Temperature: 125°C)
- Nominal Characteristic Impedance
- 84 Ohm
- Nominal Capacitance Cond-to-Cond
- 18 pF/ft (59 pF/m)
- Max. Pull Tension / Min. Bend Radius
- 9.5 lbs (4.3 kg) max pull tension, 2.6 in (66 mm) min. stationary bend radius
58809 Applications
- Data, communication, audio, and low-level signal transmission
- Industrial networking
- Serial communication
- Control panels
- Automation equipment
- Instrumentation systems
Other Belden parts
- 23538D — Belden 23538D is a Canadian instrumentation cable (TC-ACIC) with 24 pairs of 16...
- 1054A — The Belden 1054A is a UL instrumentation cable consisting of 36 pairs of 18 AWG...
- 7935A — The Belden 7935A is a DataTuff® Industrial Ethernet Cat 5e cable consisting of 4...
- 21645 — The Belden 21645 is a CSA Type TC-CIC tray cable rated 600 V for CEC power and c...
- 83609 — The Belden 83609 is a high-temperature plenum-rated (CMP) 9-conductor electronic...
- 1064 — The Belden 1064 is a communication and control cable consisting of 4 conductors...
- 29561C — Belden 29561C is a CSA-rated VFD power cable intended for variable frequency dri...
- 6158 — The Belden 6158 is a heavy-duty Teck90 1000V cable featuring 2+G bare copper con...
More Bulk Wire Cable
- 5261C — The Belden 5261C is a single-pair, 24 AWG tinned copper cable with semi-rigid PV...
- 80058 — The Belden 80058 is an 18-conductor, 14 AWG tinned copper cable with modified po...
- 3034A — The Belden 3034A is a UL-listed instrumentation cable consisting of 16 pairs of...
- 8786 — The Belden 8786 is a shielded audio, control, and instrumentation cable designed...
- 21654 — Belden 21654 is a CSA Type TC-CIC 600V tray cable with three 6 AWG (7x14) bare c...
- 2424 — The Belden 2424 is a Category 6+ enhanced premise horizontal cable featuring 4 p...
- 8885MN — The Belden 8885MN is a SpaceMaker™ 12-conductor cable featuring 22 AWG stranded...
- 2824 — The Belden 2824 is a single-conductor communication and control cable designed f...
58809 FAQ
What is 58809?
58809 is a Bulk Wire Cable from Belden. The Belden 58809 is a communication and control cable consisting of 9 pairs of 24 AWG tinned copper conductors with FEP insulation, an overall aluminum/polyester shield, and a slate PVDF outer jacket. It is rated for a UL voltage of 300 V (CMP) and a maximum operating temperature of 125°C, with an operating range of -25°C to +125°C. The cable is designed for data, communication, audio, and low-level signal transmission, as well as industrial networking, serial communication, control panels, automation equipment, and instrumentation systems.
Who manufactures 58809?
58809 is manufactured by Belden.
What is the marking code of 58809?
According to its datasheet, 58809 in Cable (Reel, 500 ft or 1,000 ft) is marked "Alpha Wire -* P/N 58809 9PR 24 AWG SHIELDED 125C (UL) TYPE CMP OR C(UL) TYPE CMP FT6 CE ROHS".
Where can I download the 58809 datasheet PDF?
The 58809 datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 58809 specifications
Click to ask a quick question:
Parameters
| Conductor | 9 pair, 24 AWG 7x32 TC - Tinned Copper |
| Insulation | FEP - Fluorinated Ethylene Propylene, nominal thickness 0.007 in (0.18 mm) |
| Max. Pull Tension / Min. Bend Radius | 9.5 lbs (4.3 kg) max pull tension, 2.6 in (66 mm) min. stationary bend radius |
| Nominal Capacitance Cond-to-Cond | 18 pF/ft (59 pF/m) |
| Nominal Characteristic Impedance | 84 Ohm |
| Nominal Overall Diameter | 0.256 in (6.50 mm) |
| Operating Temperature | -25°C to +125°C (UL Temperature: 125°C) |
| Outer Jacket | PVDF - Polyvinylidene Fluoride, nominal thickness 0.011 in (0.28 mm) |
| Outer Shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, with 24 AWG (7x32) TC drainwire |
| UL Voltage Rating | 300 V (CMP) |