5462C Datasheet

BeldenBulk Wire Cable

The 5462C is a 2-conductor, 20 AWG tinned copper shielded cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures from -30°C to +105°C. It features an overall aluminum/polyester shield with a TC drainwire and complies with multiple UL and CSA standards including AWM/STYLE 2464, CM, and CMG. This cable is designed for use in industrial control systems, instrumentation and control circuits, and PLC and DCS systems, carrying analog and digital signals.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

5462C Key Specifications

Nominal Capacitance Cond-to-Cond
43 pF/ft (140 pF/m)
Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Operating Temperature
-30°C to +105°C (UL Temperature 105°C)
Conductor
2 conductor 20 AWG (7x28) TC - Tinned Copper
Max. Pull Tension
17.6 lbs (7.98 kg)
Nominal Characteristic Impedance
49 Ohm
Nominal Outer Diameter
0.212 in (5.38 mm)
Outer Shield
Bi-Laminate (Alum+Poly) 100% coverage with 20 AWG (7x28) TC drainwire

Characteristics (datasheet)

Conductor
2 conductor 20 AWG (7x28) TC - Tinned Copper
Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Operating Temperature
-30°C to +105°C (UL Temperature 105°C)
Nominal Outer Diameter
0.212 in (5.38 mm)
Outer Shield
Bi-Laminate (Alum+Poly) 100% coverage with 20 AWG (7x28) TC drainwire
Nominal Capacitance Cond-to-Cond
43 pF/ft (140 pF/m)
Nominal Characteristic Impedance
49 Ohm
Max. Pull Tension
17.6 lbs (7.98 kg)

5462C Applications

  • Industrial control systems, raceways, cable trays, and ducts
  • Instrumentation and control circuits
  • Analog and digital signals (4–20 mA, 0–10 V)
  • PLC and DCS systems
  • Sensors, encoders, solenoids, valves, actuators, and positioners

Other Belden parts

  • 78042 — The Belden 78042 is a 2-conductor, 20 AWG tinned copper ECOCABLE with modified p...
  • 5343FE — The Belden 5343FE is a security and sound cable with a riser-CMR rating, designe...
  • 83332E — The Belden 83332E is a high-temperature, 3-conductor 26 AWG silver-plated copper...
  • 70094A — The Belden 70094A is a discontinued Category 5e industrial Ethernet cable design...
  • 9578 — The Belden 9578 is a shielded, 4-conductor 18 AWG solid bare copper cable with P...
  • 5220C — The Belden 5220C is a multi-conductor shielded/unshielded control cable featurin...
  • 85207CY — The 85207CY is a 7-conductor, 12 AWG XTRAGUARD FLEX continuous flex control cabl...
  • 77101 — The Belden 77101 is an ECOCABLE featuring 12 conductors of 24 AWG stranded tinne...

More Bulk Wire Cable

  • 9540 — The Belden 9540 is a computer EIA RS-232 cable featuring 10 stranded tinned copp...
  • 55462 — The Belden 55462 is an XTRAGUARD 5 shielded cable consisting of 2 conductors of...
  • 2634 — The Belden 2634 is a single-conductor hook-up wire featuring a 34 AWG solid nick...
  • 9718 — The Belden 9718 is a discontinued 2-conductor speaker cable made of 12 AWG stran...
  • 45292 — Belden 45292 is an XTRAGUARD 4 cable with 2 pairs of 20 AWG (7/28) stranded tinn...
  • 6352 — The Belden 6352 is a shielded communication and control cable featuring four 24...
  • 86004 — The Belden 86004 is a flexible, 4-conductor 28 AWG tinned copper cable with semi...
  • 26501D — Belden part 26501D is a Canadian Instrumentation Cable (TC-ACIC) rated 300 V, co...

5462C FAQ

What is 5462C?

5462C is a Bulk Wire Cable from Belden. The 5462C is a 2-conductor, 20 AWG tinned copper shielded cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures from -30°C to +105°C. It features an overall aluminum/polyester shield with a TC drainwire and complies with multiple UL and CSA standards including AWM/STYLE 2464, CM, and CMG. This cable is designed for use in industrial control systems, instrumentation and control circuits, and PLC and DCS systems, carrying analog and digital signals.

Who manufactures 5462C?

5462C is manufactured by Belden.

Where can I download the 5462C datasheet PDF?

The 5462C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 5462C specifications

AI Powered

Click to ask a quick question:

Parameters

Conductor2 conductor 20 AWG (7x28) TC - Tinned Copper
Max. Pull Tension17.6 lbs (7.98 kg)
Nominal Capacitance Cond-to-Cond43 pF/ft (140 pF/m)
Nominal Characteristic Impedance49 Ohm
Nominal Outer Diameter0.212 in (5.38 mm)
Operating Temperature-30°C to +105°C (UL Temperature 105°C)
Outer ShieldBi-Laminate (Alum+Poly) 100% coverage with 20 AWG (7x28) TC drainwire
Voltage Rating300 V (CMG, CM, AWM 2464, AWM 2517)