5386C Datasheet
The Belden 5386C is an XTRAGUARD 1 shielded multi-conductor cable featuring 6 conductors made of 18 AWG stranded tinned copper with PVC insulation and a slate PVC outer jacket. It is rated for a voltage of 300 V and operates within a temperature range of -30°C to +105°C. This cable is designed for industrial control systems, instrumentation and control circuits, and PLC/DCS systems, supporting analog and digital signals, sensors, and solenoids.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5386C Key Specifications
- Nominal Capacitance Cond-to-Cond
- 45 pF/ft (150 pF/m)
- Nominal Capacitance Cond-to-Other
- 81 pF/ft (270 pF/m)
- Nominal Inductance
- 0.18 µH/ft (0.59 µH/m)
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -30°C To +105°C
- Conductor count
- 6
- Conductor size
- 18 AWG (16x30 strand), TC - Tinned Copper
- Max. Pull Tension
- 27 lbs (12 kg)
Characteristics (datasheet)
- Conductor count
- 6
- Conductor size
- 18 AWG (16x30 strand), TC - Tinned Copper
- Outer Shield
- Bi-Laminate (Alum+Poly) tape, 100% coverage, with 18 AWG (16x30) TC drainwire
- Outer Jacket
- PVC - Polyvinyl Chloride, 0.032 in (0.81 mm) thickness, Slate
- Nominal Overall Diameter
- 0.311 in (7.90 mm)
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -30°C To +105°C
- Nominal Capacitance Cond-to-Cond
- 45 pF/ft (150 pF/m)
- Nominal Capacitance Cond-to-Other
- 81 pF/ft (270 pF/m)
- Nominal Inductance
- 0.18 µH/ft (0.59 µH/m)
- Nom Outer Shield DCR
- 6 Ohm/1000ft (20 Ohm/km)
- Min. Bend Radius (Stationary)
- 3.1 in (79 mm)
- Max. Pull Tension
- 27 lbs (12 kg)
5386C Applications
- Industrial control systems, raceways, cable trays, and ducts
- Instrumentation and control circuits
- Analog and digital signals (4–20 mA, 0–10 V)
- PLC and DCS systems
- Sensors, encoders, solenoids, valves, actuators, and positioners
Other Belden parts
- 28149AS — The Belden 28149AS is a UL Type TC (1277) tray cable with two 8 AWG bare copper...
- 8668 — The Belden 8668 is a tinned copper braid conductor with a size of 13.3 AWG (120x...
- 65607 — The Belden 65607 is an XTRAGUARD FLEX flexible control cable featuring seven 16...
- 9829 — The Belden 9829 is a computer EIA RS-232/422 low-capacitance cable featuring two...
- 83709 — The Belden 83709 is a high-temperature, 9-conductor 16 AWG tinned copper cable w...
- 76608TS — The Belden 76608TS is a MachFlex™ high-flex cable designed specifically for robo...
- 28083A — The Belden 28083A is a 5-conductor 14 AWG (7x22 bare copper) power and control c...
- 2177A — The Belden 2177A is a low-loss serial digital coaxial cable (RG-7 type) featurin...
More Bulk Wire Cable
- 79842ELZ — The 79842ELZ is a dual-pair, 24 AWG stranded tinned copper conductor cable with...
- 43906LW — The Belden 43906LW is a 2-pair 22 AWG/0.34 mm² DMX512 lighting control cable wit...
- 5453C — The Belden 5453C is an XTRAGUARD 1 shielded multi-conductor cable featuring 3 pa...
- 23514D — Belden 23514D is a 300 V Canadian instrumentation cable (TC-ACIC) with four pair...
- 9502 — The Belden 9502 is a computer EIA RS-232 cable featuring two 24 AWG stranded tin...
- 32412 — The Belden 32412 is a rubber lead wire with 12 AWG tinned copper conductors (19x...
- 78304 — The Belden 78304 is a shielded multi-conductor cable (ECOCABLE) consisting of fo...
- 2254 — The Belden 2254 is a communication and control cable consisting of two 22 AWG ti...
5386C FAQ
What is 5386C?
5386C is a Bulk Wire Cable from Belden. The Belden 5386C is an XTRAGUARD 1 shielded multi-conductor cable featuring 6 conductors made of 18 AWG stranded tinned copper with PVC insulation and a slate PVC outer jacket. It is rated for a voltage of 300 V and operates within a temperature range of -30°C to +105°C. This cable is designed for industrial control systems, instrumentation and control circuits, and PLC/DCS systems, supporting analog and digital signals, sensors, and solenoids.
Who manufactures 5386C?
5386C is manufactured by Belden.
Where can I download the 5386C datasheet PDF?
The 5386C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5386C specifications
Click to ask a quick question:
Parameters
| Conductor count | 6 |
| Conductor size | 18 AWG (16x30 strand), TC - Tinned Copper |
| Max. Pull Tension | 27 lbs (12 kg) |
| Min. Bend Radius (Stationary) | 3.1 in (79 mm) |
| Nominal Capacitance Cond-to-Cond | 45 pF/ft (150 pF/m) |
| Nominal Capacitance Cond-to-Other | 81 pF/ft (270 pF/m) |
| Nominal Inductance | 0.18 µH/ft (0.59 µH/m) |
| Nominal Overall Diameter | 0.311 in (7.90 mm) |
| Nom Outer Shield DCR | 6 Ohm/1000ft (20 Ohm/km) |
| Operating Temperature | -30°C To +105°C |
| Outer Jacket | PVC - Polyvinyl Chloride, 0.032 in (0.81 mm) thickness, Slate |
| Outer Shield | Bi-Laminate (Alum+Poly) tape, 100% coverage, with 18 AWG (16x30) TC drainwire |
| Voltage Rating | 300 V (CMG, CM, AWM 2464, AWM 2517) |