The Belden 5279C is a 9-pair, 24 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and an operating temperature range of -35°C to +105°C, suitable for industrial control systems, instrumentation, analog and digital signal transmission, and PLC/DCS systems.

Download PDF(catalog.belden.com)

Datasheet published by Belden

Open the PDF on catalog.belden.com with the Download PDF button

5279C Key Specifications

Nom. Capacitance Cond-to-Cond
22.5 pF/ft (73.8 pF/m)
Nom. Capacitance Cond-to-Other
40 pF/ft (130 pF/m)
Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Operating Temperature
-35°C To +105°C
Bend Radius (Min. Stationary / Installation)
2.9 in (74 mm)
Characteristic Impedance
83 Ohm
Conductor
9 Pair(s), 24 AWG 7x32 TC - Tinned Copper
Max. Pull Tension
36 lbs (16 kg)

5279C Marking Code (SMD Code)

Top marking: Alpha Wire -* P/N 5279C 9PR 24 AWG XTRAGUARD(R) 1 SHIELDED (UL) TYPE CM 105C SUN RES OR AWM 2464 80C 300V OR AWM 2517 105C 300V VW-1 --- LLXXXXXX

Characteristics (datasheet)

Voltage Rating
300 V (CMG, CM, AWM 2464, AWM 2517)
Operating Temperature
-35°C To +105°C
Conductor
9 Pair(s), 24 AWG 7x32 TC - Tinned Copper
Nominal Outer Diameter
0.360 in (9.14 mm)
Characteristic Impedance
83 Ohm
Nom. Capacitance Cond-to-Cond
22.5 pF/ft (73.8 pF/m)
Nom. Capacitance Cond-to-Other
40 pF/ft (130 pF/m)
Shielding
Tape Bi-Laminate (Alum+Poly) 100% coverage, Braid Tinned Copper (TC) 70% coverage
Max. Pull Tension
36 lbs (16 kg)
Bend Radius (Min. Stationary / Installation)
2.9 in (74 mm)

5279C Applications

  • Industrial control systems, raceways, cable trays, and ducts
  • Instrumentation and control circuits
  • Analog and digital signals (4–20 mA, 0–10 V)
  • PLC and DCS systems
  • Sensors, encoders, solenoids, valves, actuators, and positioners

Other Belden parts

  • 24507D — The Belden 24507D is a Canadian Instrumentation Cable (TC-ACIC) rated 600 V RMS,...
  • 78109 — The Belden 78109 is a multi-conductor ECOCABLE consisting of 9 pairs of 28 AWG s...
  • 86606CY — The 86606CY is an XTRAGUARD FLEX continuous flex data cable featuring 6 pairs of...
  • 79258 — The 79258 is a 4-conductor, 26 AWG stranded tinned copper cable with mPPE insula...
  • 3533 — The Belden 3533 is a multi-conductor hook-up wire consisting of 30 tinned copper...
  • 45074 — Belden part 45074 is an XTRAGUARD 4 cable with four 16 AWG stranded tinned coppe...
  • 23509 — The Belden 23509 is a Type ACIC Canadian instrumentation cable rated 300 V, cons...
  • 1524AM — The Belden 1524AM is an RG11 type CATV video cable featuring a 14 AWG solid bare...

More Bulk Wire Cable

  • 7803A — The 7803A is a discontinued video triax cable of RG11 type, featuring a 14 AWG s...
  • 58401 — The Belden 58401 is a plenum-rated, shielded communication and control cable des...
  • 55371 — The Belden 55371 is a high-performance shielded single-pair cable designed for d...
  • 76403TS — The Belden 76403TS is a MachFlex™ high-flex, 3-pair 28AWG tinned copper cable wi...
  • 74046NH — The Belden 74046NH is a DataTuff Industrial Single Pair Ethernet (SPE) cable des...
  • 5300C — The Belden 5300C (XTRAGUARD 1) is a 5-conductor, 24 AWG tinned copper cable with...
  • 1861A — The Belden 1861A is a plenum-rated (CL2P) unshielded speaker cable designed for...
  • 2119A — The Belden 2119A is a 600V TC-ER rated fieldbus cable designed for harsh environ...

5279C FAQ

What is 5279C?

5279C is a Bulk Wire Cable from Belden. The Belden 5279C is a 9-pair, 24 AWG tinned copper cable with semi-rigid PVC insulation, an overall aluminum/polyester shield, and a slate PVC outer jacket. It is rated for 300 V and an operating temperature range of -35°C to +105°C, suitable for industrial control systems, instrumentation, analog and digital signal transmission, and PLC/DCS systems.

Who manufactures 5279C?

5279C is manufactured by Belden.

What is the marking code of 5279C?

According to its datasheet, 5279C is marked "Alpha Wire -* P/N 5279C 9PR 24 AWG XTRAGUARD(R) 1 SHIELDED (UL) TYPE CM 105C SUN RES OR AWM 2464 80C 300V OR AWM 2517 105C 300V VW-1 --- LLXXXXXX".

Where can I download the 5279C datasheet PDF?

The 5279C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.

Specifications

Manufacturer
Belden

Ask AI Assistant

Ask questions about 5279C specifications

AI Powered

Click to ask a quick question:

Parameters

Bend Radius (Min. Stationary / Installation)2.9 in (74 mm)
Characteristic Impedance83 Ohm
Conductor9 Pair(s), 24 AWG 7x32 TC - Tinned Copper
Max. Pull Tension36 lbs (16 kg)
Nom. Capacitance Cond-to-Cond22.5 pF/ft (73.8 pF/m)
Nom. Capacitance Cond-to-Other40 pF/ft (130 pF/m)
Nominal Outer Diameter0.360 in (9.14 mm)
Operating Temperature-35°C To +105°C
ShieldingTape Bi-Laminate (Alum+Poly) 100% coverage, Braid Tinned Copper (TC) 70% coverage
Voltage Rating300 V (CMG, CM, AWM 2464, AWM 2517)