The Belden 5132C is a shielded, 2-pair, 18 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures from -30°C to +105°C. It features an overall aluminum/polyester shield and a tinned copper braid for noise protection. It is commonly used in industrial control systems, instrumentation, analog/digital signal transmission, and PLC/DCS systems.
Datasheet published by Belden
Open the PDF on catalog.belden.com with the Download PDF button
5132C Key Specifications
- Nom. Capacitance Cond-to-Cond
- 40 pF/ft (130 pF/m)
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -30°C To +105°C
- Characteristic Impedance
- 49 Ohm
- Conductor
- 2 Pair, 18 AWG 16x30 TC - Tinned Copper
- Max. Pull Tension
- 367 lbs (166 kg)
- Min. Bend Radius (Stationary / Installation)
- 1.8 in (46 mm)
- Nominal Overall Diameter
- 0.355 in (9.02 mm)
Characteristics (datasheet)
- Voltage Rating
- 300 V (CMG, CM, AWM 2464, AWM 2517)
- Operating Temperature
- -30°C To +105°C
- Conductor
- 2 Pair, 18 AWG 16x30 TC - Tinned Copper
- Nominal Overall Diameter
- 0.355 in (9.02 mm)
- Characteristic Impedance
- 49 Ohm
- Nom. Capacitance Cond-to-Cond
- 40 pF/ft (130 pF/m)
- Max. Pull Tension
- 367 lbs (166 kg)
- Min. Bend Radius (Stationary / Installation)
- 1.8 in (46 mm)
5132C Applications
- Industrial control systems, raceways, cable trays, and ducts
- Instrumentation and control circuits
- Analog and digital signals (4–20 mA, 0–10 V)
- PLC and DCS systems
- Sensors, encoders, solenoids, valves, actuators, and positioners
Other Belden parts
- 4401FE — The Belden 4401FE is a security and commercial audio cable with three 20 AWG str...
- 78158 — The Belden 78158 is an 8-pair, 28 AWG tinned copper conductor cable (ECOCABLE) w...
- 8012 — The Belden 8012 is a bus bar wire featuring a 14 AWG solid tinned copper conduct...
- 5675 — The Belden 5675 is a 3-conductor, 26 AWG tinned copper cable with semi-rigid PVC...
- 85634 — The Belden 85634 is an XTRAGUARD FLEX continuous flex control cable featuring 34...
- 1190A — The Belden 1190A is an RG6 type coaxial CATV video cable featuring an 18 AWG sol...
- 29005 — Belden 29005 is a 600 V ACIC power and control cable with six 16 AWG stranded ba...
- 29542 — Belden part 29542 is a flexible 2000 V VFD motor supply cable with three 2 AWG (...
More Bulk Wire Cable
- 9772 — The Belden 9772 is an audio and instrumentation cable containing 12 individually...
- 7123WS — The Belden 7123WS is a high-flex, 3+1 conductor 16 AWG bare copper cable designe...
- 25373 — Belden 25373 is an XTRAGUARD 2 cable with 3 shielded pairs of 18 AWG (16x30) tin...
- 58804 — The Belden 58804 is a communication and control cable featuring 4 pairs of 24 AW...
- 4406FE — The 4406FE is a security and commercial audio cable featuring 8 stranded bare co...
- 86005 — The part 86005 is a 5-conductor 28 AWG tinned copper cable with semi-rigid PVC i...
- 3542 — The Belden 3542 is a 20-conductor hook-up wire featuring 24 AWG stranded tinned...
- 2111A — The Belden 2111A is a 5-pair 16 AWG tinned copper fieldbus cable with XLPO insul...
5132C FAQ
What is 5132C?
5132C is a Bulk Wire Cable from Belden. The Belden 5132C is a shielded, 2-pair, 18 AWG tinned copper cable with PVC insulation and a slate PVC outer jacket, rated for 300 V and temperatures from -30°C to +105°C. It features an overall aluminum/polyester shield and a tinned copper braid for noise protection. It is commonly used in industrial control systems, instrumentation, analog/digital signal transmission, and PLC/DCS systems.
Who manufactures 5132C?
5132C is manufactured by Belden.
Where can I download the 5132C datasheet PDF?
The 5132C datasheet PDF is published by Belden; the Download PDF button on this page opens it on the manufacturer's website.
Specifications
- Manufacturer
- Belden
Ask AI Assistant
Ask questions about 5132C specifications
Click to ask a quick question:
Parameters
| Characteristic Impedance | 49 Ohm |
| Conductor | 2 Pair, 18 AWG 16x30 TC - Tinned Copper |
| Max. Pull Tension | 367 lbs (166 kg) |
| Min. Bend Radius (Stationary / Installation) | 1.8 in (46 mm) |
| Nom. Capacitance Cond-to-Cond | 40 pF/ft (130 pF/m) |
| Nominal Overall Diameter | 0.355 in (9.02 mm) |
| Operating Temperature | -30°C To +105°C |
| Voltage Rating | 300 V (CMG, CM, AWM 2464, AWM 2517) |